• 제목/요약/키워드: Switching loss

검색결과 1,109건 처리시간 0.025초

PFC용 부스트 컨버터의 효율 개선에 관한 연구 (A Study on the Efficiency Improvement of Boost Converter for Power Factor Correction)

  • 전내석;전수균;이성근;길경석;김윤식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1094-1096
    • /
    • 2002
  • A new technique for improving the efficiency of single-phase high-frequency boost converter is proposed. This converter includes an additional low-frequency boost converter which is connected to the main high-frequency switching device in parallel. The additional converter is controlled at lower frequency. Most of the current flows in the low-frequency switch and so, high-frequency switching loss is greatly reduced accordingly. Both switching device are controlled by a simple method; each controller consists of a comparator, a frequency generator and an error amplifier. The converter works cooperatively in high efficiency and acts as if it were a conventional high-frequency boost converter with one switching device, The proposed method is verified by simulation and experiment. This paper describes the converter configuration and design, and discusses the steady-state performance concerning the switching loss reduction and efficiency improvement.

  • PDF

고효율 절연형 DC-DC 초퍼의 특성해석 (Performance Analysis of High Efficiency DC-DC Chopper added in Electric Isolation)

  • 곽동걸;이봉섭;김춘삼;정도영;김수광
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.115-117
    • /
    • 2007
  • This paper is analyzed for DC-DC chopper performance of high efficiency added in electric isolation. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve high efficiency system, the proposed chopper is constructed by using a partial resonant circuit. The control switches using in the chopper are operated with soft switching for a partial resonant method. The control switches are operated without increasing their voltage and current stresses by the soft switching technology. The result is that the switching loss is very low and the efficiency of chopper is high. And the proposed chopper is added in a electric isolation. When the power conversion system is required to electric isolation, the proposed chopper is adopted with system development of high efficiency. The soft switching operation and the system efficiency of the proposed chopper is verified by digital simulation and experimental results.

  • PDF

전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법 (Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI)

  • 박준철;박찬배;백제훈;곽상신
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-279
    • /
    • 2015
  • A zero vector selection method to reduce switching losses for model predictive control (MPC) of voltage source inverter is proposed. A conventional MPC of voltage source inverter has not been proposed, and a method to select the redundancy of the zero vector is required for this study. In this paper, the redundancy of the zero vectors is selected with generating a zero sequence voltage to reduce switching losses. The zero vector of 2-level inverter is determined by determining sign of the zero sequence voltage. In the proposed method, the quality of the current is retained and switching loss can be reduced compared with the conventional method. This result was verified by P-sim simulation and experiments.

Improving the Overall Efficiency for DC/DC Converter with LoV-HiC System

  • Han, Dong-Hwa;Lee, Young-Jin;Kwon, Wan-Sung;Bou-Rabee, Mohammed A.;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.418-428
    • /
    • 2012
  • It is very important to improve the overall efficiency of systems with a source of power that has low-voltage high-current terminal characteristics such as fuel cells. A resonant converter is required for high efficiency systems. However, the peak value of the switches current is large in a resonant converter. This peak current requires a large number of switches and results in system failures. In this paper, an analysis and experiments of a resonant isolation push-pull converter are performed. A switching loss analysis is performed in order to compare losses between a resonant push pull converter and a hard switching push-pull converter. Specially, the conduction loss is studied based on the ratio between the resonant frequency and the switching frequency. In addition, a method for improving the efficiency is implemented with conventional HF insolation converters.

Design of Parasitic Inductance Reduction in GaN Cascode FET for High-Efficiency Operation

  • Chang, Woojin;Park, Young-Rak;Mun, Jae Kyoung;Ko, Sang Choon
    • ETRI Journal
    • /
    • 제38권1호
    • /
    • pp.133-140
    • /
    • 2016
  • This paper presents a method of parasitic inductance reduction for high-speed switching and high-efficiency operation of a cascode structure with a low-voltage enhancement-mode silicon (Si) metal-oxide-semiconductor field-effect transistor (MOSFET) and a high-voltage depletion-mode gallium nitride (GaN) fielde-ffect transistor (FET). The method is proposed to add a bonding wire interconnected between the source electrode of the Si MOSFET and the gate electrode of the GaN FET in a conventional cascode structure package to reduce the most critical inductance, which provides the major switching loss for a high switching speed and high efficiency. From the measured results of the proposed and conventional GaN cascode FETs, the rising and falling times of the proposed GaN cascode FET were up to 3.4% and 8.0% faster than those of the conventional GaN cascode FET, respectively, under measurement conditions of 30 V and 5 A. During the rising and falling times, the energy losses of the proposed GaN cascode FET were up to 0.3% and 6.7% lower than those of the conventional GaN cascode FET, respectively.

Zero-Voltage and Zero-Current Switching Interleaved Two-Switch Forward Converter

  • Chu, Enhui;Bao, Jianqun;Song, Qi;Zhang, Yang;Xie, Haolin;Chen, Zhifang;Zhou, Yue
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1413-1428
    • /
    • 2019
  • In this paper, a novel zero-voltage and zero-current switching (ZVZCS) interleaved two switch forward converter is proposed. By using a coupled-inductor-type smoothing filter, a snubber capacitor, the parallel capacitance of the leading switches and the transformer parasitic inductance, the proposed converter can realize soft-switching for the main power switches. This converter can effectively reduce the primary circulating current loss by using the coupled inductor and the snubber capacitor. Furthermore, this converter can reduce the reverse recovery loss, parasitic ringing and transient voltage stress in the secondary rectifier diodes caused by the leakage inductors of the transformer and the coupled inductance. The operation principle and steady state characteristics of the converter are analyzed according to the equivalent circuits in different operation modes. The practical effectiveness of the proposed converter was is illustrated by simulation and experimental results via a 500W, 100 kHz prototype using the power MOSFET.

The Study on Miniaturization and Weight Reduction of Auxiliary Power Unit in Magnetic Levitation Train

  • Lee, Na Ri;Shin, Hee Keun;Choi, Sung Ho;Kim, Ju Bum;Lim, Jae Won;Park, Doh Young;Mok, Hyung Soo
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.10-14
    • /
    • 2015
  • Due to the characteristics of the vehicle structure, the magnetic levitation train has a confined bottom space thus a study on miniaturization and weight reduction of auxiliary power unit is essential. This auxiliary power unit is an essential device used for illumination, air conditioning, heating and air brake equipment excluding the motor. The previous auxiliary power unit for magnetic levitation train has used the hard switching having a high switching frequency with heavy loss in order to reduce the size of filter reactor and transformer but the reduction in volume was not significant. In this paper, by reducing the loss, reducing the size of the cooling unit and by increasing the switching frequency using the soft switching of resonant converter, it has miniaturized and reduced the weight of filter reactor and transformer which occupy significant space in the auxiliary power unit. This study has verified the performance of 50KVA grade prototype through simulated interpretation and analysis, and compared the size and weight of auxiliary power unit of the previous magnetic levitation train.

The effect of switching costs on resistance to change in the use of software

  • Perera, Nipuna;Kim, Hee-Woong
    • 한국경영정보학회:학술대회논문집
    • /
    • 한국경영정보학회 2007년도 International Conference
    • /
    • pp.539-544
    • /
    • 2007
  • People tend to resist changing their software even alternatives are better then the current one. This study examines the resistance to change in the use of software from the switching costs perspective based on status quo bias theory. For this study, we select Web Browsers as software. Based on the classification of switching costs into three groups (psychological, procedural, and loss), this study identifies six types of switching costs (uncertainty, commitment, learning, setup, lost performance, and sunk costs). This study tests the effects of six switching costs on user resistance to change based on the survey of 204 web browser users. The results indicate that lost performance costs and emotional costs have significant effects on user resistance to change. This research contributes towards understanding of switching costs and the effects on user resistance to change. This study also offers suggestions to software vendors for retaining their users and to organizations for managing user resistance in switching and adopting software.

  • PDF

소프트 스위칭 방식의 보조 회로를 갖는 영전류 및 영전압 스위칭 양방향 DC-DC 컨버터 (A Family of Zero Current and Zero Voltage Switching Bidirectional DC-DC Converter with Soft Switched Auxiliary Circuit)

  • 이일호;김준구;김재형;원충연;정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.438-439
    • /
    • 2011
  • In this paper, soft switching bidirectional DC-DC converter is proposed. The proposed topology is added two auxiliary switches, two resonant capacitors and one resonant inductor to convectional bidirectional DC-DC converter. Therefore, this proposed topology can reduce switching loss of each power switch by ZVS (Zero Voltage Switching) and ZCS (Zero Current Switching). We have performed mode analysis, simulation and experiment for the proposed topology.

  • PDF

동기 정류기를 이용한 클램프 모드 포워드 다중 공진형 컨버터 (Clamp mode forward multi-resonant conveter with synchronous rectifier)

  • 안강순;김희준
    • 전자공학회논문지S
    • /
    • 제34S권2호
    • /
    • pp.112-120
    • /
    • 1997
  • The clamp mode (CM) forward zero voltage switching multi resonant converter (ZVS-MPC) with self-driven synchronous rectifier is studied. The loss at the synchronous rectification stage of the converter is analyzed using MOSFET piecewise linear model and is compared with the loss at the conventional schottky diode rectification stage of th econverter. From the results of the analysis, it is known that the use fo MOSFETs as a synchronous rectifier reduces the loss at the rectification stage overthe whole load range comparing the use of schottky diodes as a conventional rectifier in the converter. In order to verify the validit of the analysis, we have built a 33W(3.3V/10A) CM forward ZVS-MRC with self-driven synchronous rectifier, in which switching frequency is 1MHz, and tested. FRom the experimental results, it is known that the synchronous rectification achieved about 1W improvement in the loss at the rectification stage and about 3% in the efficiency at the converter as compared with the conventional schottky diode rectification.

  • PDF