• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.032 seconds

Managed Object and Distributed Network Management Model in Open Interface of OBS Network (개방형 인터페이스가 적용된 OBS 망의 관리객체 및 분산 망 관리 모델)

  • Kwon TaeHyun;Kim ChoonHee;Cha YoungWook
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.449-456
    • /
    • 2005
  • Optical burst switching (OBS) overcomes the inefficient resource usage of optical circuit switching and minimizes the optical buffering requirement of optical packet switching. General switch management protocol (GSMP) is an open interface between a label switch and a controller, and it provides connection, configuration, performance, event management and synchronization. GSMP open interface in the OBS network allows the implementation of OBS switch to be simple by separating the data forward plane from the control plane. We defined managed objects to support connection, configuration, performance, and fault management for the management of OBS network in the GSMP open interface. We proposed the network management model, in which the above managed objects are distributed in a controller and an OBS switch according to network management functions. We verified the possibility of connection management using distributed network management model in the GSMP open interface of OBS network by implementing GSMP and network management functions with managed objects of OBS.

A Study on Implementation of a VC-Merge Capable High-Speed Switch on MPLS over ATM (ATM기반 MPLS망에서 VC-Merge 가능한 고속 스위치 구현에 관한 연구)

  • Kim, Young-Chul;Lee, Tae-Won;Lee, Dong-Won
    • The KIPS Transactions:PartC
    • /
    • v.9C no.1
    • /
    • pp.65-72
    • /
    • 2002
  • In this paper, we implement a high-speed swatch tilth the function for label integration to enhance the expansion of networks using the label space of routers efficiently on MPLS over ATM networks. We propose an appropriate hardware structure to support the VC-merge function and differentiated services simultaneously. In this paper, we use the adaptive congestion control method such as EPD algorithm in carte that there is a possibility of network congestion in output buffers of each core LSR. In addition, we justify the validity of the proposed VC-merge method through simulation and comparison to conventional Non VC-merge methods. The proposed VC-merge capable switch is modeled in VHDL. synthesized, and fabricated using the SAMSUNG 0.5um SOG process.

Characteristics of a Parallel Interworking Model for Open Interface of Optical Internet (광 인터넷의 개방형 인터페이스를 위한 병렬형 연동 모델의 특성)

  • Kim, Choon-Hee;Baek, Hyun-Gyu;Cha, Young-Wook;Choi, Jun-Kyun
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.4
    • /
    • pp.405-411
    • /
    • 2002
  • Open interfaces in the optica] Internet have been progressed by OIF's ISI, ITU-T ASTN's CCI and IETF's GSMP extensions with optical switching. These open interfaces enable the separation between the control plane and the optical transport plane. This separation allows flexibility in the network, but it suffers more setup delay than the traditional switch-by-switch connection setup. We propose the parallel interworking model, which will reduce the connection setup delay in the open interface of optical Internet. Based on the switch controller's caching capability about networks states, the parallel interworking procedures between signaling protocol and GSMP protocol are performed in the switch controller. We simulated and evaluated our proposed parallel interworking model and the existing sequential interworking model in terms of a connection setup delay and a completion ratio. We observed that the completion ratios of the two interworking models were quite close. However the connection setup delay of parallel interworking model is improved by about 30% compared with that of the sequential interworking model.

Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System (5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법)

  • Baek, Seung-Koo;Shin, Hye-Ung;Kang, Seong-Yun;Park, Choon-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

Implementation of Position Control of PMSM with FPGA

  • Reaugepattanawiwat, Chalermpol;Eawsakul, Nitipat;Watjanatepin, Napat;Pinprathomrat, Prasert;Desyoo, Phayung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1254-1258
    • /
    • 2004
  • This paper presents of position control of Permanent Magnet Synchronous Motor (PMSM) the implementation with Field Programmable Gate Array (FPGA) is proposed. Cascade control with inner loop as a current control and an outer loop as a position control is chosen for simplicity and fast response. FPGA is a single chip (single processing unit), which will perform the following tasks: receive and convert control signal, create a reference current signal, control current and create switch signal and act as position controller in a addition of zero form. The 10 kHz sampling frequency and 25 bit of floating point data are defined in this implementation.The experimental results show that the performance of FPGA based position control is comparable with the hardware based position control, with the advantage of control algorithm flexibility

  • PDF

Design of Robust, Optimal Controller using Sliding Mode (슬라이딩 모드를 이용한 견실 최적 제어기 설계)

  • Byun, Ji-Young;You, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.580-583
    • /
    • 2003
  • The general time optimal control law provides the optimal solution for a minimum time control problem. But in most real systems with disturbances and model uncertainties, the time optimal control law leads to chattering effect. This chattering effect can cause the system to be unstable. Therefore, we propose a robust optimal control algorithm for the nonlinear second order systems with model uncertainty. The proposed algorithm is combined with bang-bang control and sliding mode control. Thus the proposed algorithm has two state space regions to implement to control algorithm. In each region, the appropriate linear or nonlinear feedback control law is used satisfying the dynamic system equations. Simulation results show the superiority of the proposed controller in comparison with pure time optimal control(bang-bang control).

  • PDF

The Buck DC-DC Converter with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • Kim Sang-Don;Ra Byung-Hun;Lee Hyun-Woo;Kim Kwang-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.470-475
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of do-dc converter. In this control method, the duty ratio of a switch is exactly equal In or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM

  • PDF

Instantaneous Following PWM Control Strategy of Cuk Converter Using Integrator (적분기를 이용한 Cuk 컨버터의 순시추종형 PWM 제어)

  • Shon, Je-Bong;Jeong, Soon-Yang;Kim, Kwang-Tae;Lee, Woo-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.103-105
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of Cuk converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with Cuk converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

Flow/Pressure/Power Control of Hydraulic Pump Utilizing Switching Control Mode (스위칭 제어 모드를 이용한 유압펌프의 유량/압력/동력 제어)

  • Jung, D.S.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.8-14
    • /
    • 2007
  • The electro-hydraulic pump is usually used in testing equipments which require one control function. But until now, it is not applied to industrial equipments which are exposed to severe working environment and require various control functions. This paper proposes a technique which controls continuously flow, pressure and power by utilizing switching control mode. Mathematical model is developed from the continuity equation for the pressurized control volume and the torque balance for the swash plate motion. To simplify the model we make the linear state equation by differentiating the nonlinear model. We analyze the stability and disturbance by using the state variable model. Finally, we review the control performances of flow, pressure and power by tests using PID controller.

  • PDF

Characteristic Analysis of Buck Converter by using the Non-Linear Instantaneous Following PWM Controller (강압형 컨버터의 비선형 순시추종 PWM 제어기의 특성 분석)

  • Ra, Byung-Hun;Kim, Sang-Don;Kwon, Soon-Kurl;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.378-381
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of DC-DC converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF