• Title/Summary/Keyword: Surgery, Oral

Search Result 5,555, Processing Time 0.037 seconds

Aqueous Extracts of Jibaekjihwang-tang Ameliorate Ovariectomy-induced Climacterium Symptoms in Mouse (난소적출 마우스에서 지백지황탕 열수 추출물의 갱년기 장애 개선 효과 평가)

  • Lee, Seung-Hye;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.2
    • /
    • pp.16-36
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the anti-climacterium effects of Jibaekjihwang-tang (JBJHT), especially on estrogenic, anti-obesity, hypolipidemic, hepatoprotective against fatty liver and anti-osteoporotic effects by Ovariectomy (OVX) mice. Methods: In order to evaluate anti-climacterium effects of JBJHT, we used bilateral OVX female ddY mice. In this study, six groups were used; sham control, OVX control, estradiol, JBJHT 500, 250 and 125 mg/kg treated groups. Since 28 days after OVX surgery, JBJHT extracts were orally treated, and $17{\beta}$-estradiol $0.03{\mu}g/head$ were subcutaneously injected for 84 days, once a day. And then, we observed anti-climacterium effects classified into five categories; estrogenic, anti-obesity, hypolipidemic, hepatoprotective against fatty liver and anti-osteoporotic effects. The results were compared with $17{\beta}$-estradiol $0.03{\mu}g/head$/day subcutaneous treated OVX mice. Results: OVX control mice showed noticeable hypertrophic changes of adipocytes in abdominal fat pads, fatty liver, uterine atrophic changes, decreases of bone strength were also observed in OVX control. However, these estrogen-deficient climacterium symptoms were significantly and dose-dependently inhibited by JBJHT 500, 250 and 125 mg/kg treatment. Moreover, JBJHT 500 mg/kg showed comparable inhibitory effects as compared to those of estradiol $0.03{\mu}g/head$/day subcutaneous treatment. Conclusions: The results suggest that oral administration of JBJHT 500, 250 and 125 mg/kg has clear dose-dependent anti-climacterium effects in OVX mice.

The expression of MMP-1, -8, and -13 mRNA in the periodontal ligament of rats during tooth movement with cortical punching (백서의 치아이동 시 피질골 천공이 치주조직의 MMP-1, -8, -13 mRNA의 발현에 미치는 영향)

  • Gwack, Choon;Kim, Seong-Sik;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Deok;Jun, Eun-Sook;Park, Mi-Hwa
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.187-201
    • /
    • 2008
  • Objective: The aim of this study was to determine whether cortical punching stimulates the expression of matrix metalloproteinase-1, -8, and -13 in orthodontic tooth movement in rats. Methods: A total of 32 male sprague-dawley rats at 15 weeks old were divided into two groups of 16 rats each, to form the tooth movement with cortical punching (TMC) group and tooth movement only (TM) group. A total of 20 gm of orthodontic force was applied to rat incisors to cause experimental tooth movement. Cortical punching was performed on the palatal side near the central incisor with a 1.0 mm width microscrew in the TMC group. The duration of tooth movement was 1, 4, 7, and 14 days. Results: Measurements of the mRNA expression were selected as the means to determine the identification of expression of MMP-1, -8, and -13. In the TMC group, the expression of collagen type I was greater than that of the TM group from day 4 to day 14. Expression of TIMP-1 in the TM group was greater than that of the TMC group in the pressure side of PDL and alveolar bone cell at day 4. In the TMC group, TIMP-1 was expressed at the osteoclast, but not at the tooth surface of the TM group at day 14, Maximum induction of the mRNA of MMP-1 was observed on day 4 in the TMC group, but it was observed on day 7 in the TM group. MMP-8 mRNA of the TMC group was twice greater than that of the TM group at f days. In the TMC group, maximum induction of MMP-13 mRNA was observed on day 1. Conclusions: These findings suggested that cortical punching can stimulate remodeling of PDL and alveolar bone connective tissues during experimental orthodontic tooth movement in rats.

Phosphodiesterase III Inhibitor Cilostazol Protects Amyloid β-Induced Neuronal Cell Injury via Peroxisome Proliferator-Activated Receptor-γ Activation (Amyloid β에 의해 유도된 신경세포 손상에 대한 phosphodiesterase III inhibitor인 cilostazol의 신경보호 효과)

  • Park, Sun-Haeng;Kim, Ji-Hyun;Bae, Sun-Sik;Hong, Ki-Whan;Choi, Byung-Tae;Shin, Hwa-Kyoung
    • Journal of Life Science
    • /
    • v.21 no.5
    • /
    • pp.647-655
    • /
    • 2011
  • The neurotoxicity of aggregated amyloid ${\beta}$ ($A{\beta}$) has been implicated as a critical cause in the pathogenesis of Alzheimer's disease (AD). It can cause neurotoxicity in AD by evoking a cascade of apoptosis to neuron. Here, we investigated the neuroprotective effects of cilostazol, which acts as a phosphodiesterase III inhibitor, on $A{\beta}_{25-35}$-induced cytotoxicity in mouse neuronal cells and cognitive decline in the C57BL/6J AD mouse model via peroxisome proliferator-activated receptor (PPAR)-${\gamma}$ activation. $A{\beta}_{25-35}$ significantly reduced cell viability and increased the number of apoptotic-like cells. Cilostazol treatment recovered cells from $A{\beta}$-induced cell death as well as rosiglitazone, a PPAR-${\gamma}$ activator. These effects were suppressed by GW9662, an antagonist of PPAR-${\gamma}$ activity, indicative of a PPAR-${\gamma}$-mediated signaling. In addition, cilostazol and rosiglitazone also restored PPAR-${\gamma}$ activity levels that had been altered as a result of $A{\beta}_{25-35}$ treatment, which were antagonized by GW9662. Furthermore, cilostazol also markedly decreased the number of apoptotic-like cells and decreased the Bax/Bcl-2 ratio. Intracerebroventricular injection of $A{\beta}_{25-35}$ in C57BL/6J mice resulted in impaired cognitive function. Oral administration of cilostazol (20 mg/kg) for 2 weeks before $A{\beta}_{25-35}$ injection and once a day for 4 weeks post-surgery almost completely prevented the $A{\beta}_{25-35}$-induced cognitive deficits, as did rosiglitazone. Taken together, our findings suggest that cilostazol could attenuate $A{\beta}_{25-35}$-induced neuronal cell injury and apoptosis as well as promote the survival of neuronal cells, subsequently improving cognitive decline in AD, partly because of PPAR-${\gamma}$ activation. The phosphodiesterase III inhibitor cilostazol may be the basis of a novel strategy for the therapy of AD.

Experimental Study on the Effects of Ovariectomy and Estrogen on the Bone Pattern of Mandible in Rats (난소적출과 에스트로젠 투여가 백서의 하악골 구조에 미치는 영향)

  • Lee, Hyung-Soon;Hong, Sung-Gyu;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.83-94
    • /
    • 1999
  • The purpose of this study was to evaluate the changes of cancellous and cortical bone and the effect of estrogen in ovariectomized rats. Fifty female rats, 250gm in body weight, were divided into three groups : ovariectomized group(OVE), ovariectomized and estrogen-injected group(OVE-EST), and sham operated and estrogen-injected group(EST). Bilateral ovariectomy was performed at the onset of the experiment. In OVE-EST group and EST group, estrogen was injected $50{\mu}g/kg$ B.W. every other days from 3 weeks after surgery to sacrifice. Each five rats were sacrificed after 5, 6, 7 weeks. One side of mandibular body was radiographed with a soft x-ray apparatus(Hitex Co., Ltd., Japan). Thereafter the obtained microradiographs were used for the morphometric analysis using a Image analyzer. The morphometric analysis was perforrmed for parameters such as total bone area, cortex bone area and medullary bone area. The other side of the mandibular bone was decalcified and embedded in paraffin as using a general method. The specimens were sectioned and stained with Mallory's anilline blue and observed light microscopically. The results were as follows. 1 In all groups, the proportion of cortex to total bone area was not significantly different. 2. In ovariectomized(OVE) group, the proportion of marrow cavity to medullary bone area increased significantly from 5 to 7 weeks(p<0.05). In ovariectomized and estrogen-injected(OVE-EST) group, it decreased significantly at 7 weeks, and in estrogen-injected(EST) group, it decreased significantly from 6 weeks(p<0.05). 3. Microradiogram and histopathologic findings revealed that marrow cavity was enlarged and osteoclasts were observed around irregular bone surface in OVE group. In OVE-EST group, the size of marrow cavity at 7 weeks was similar to that of control group. In EST group, as dense trabecular bone increased from 5 to 7 weeks, marrow cavity decreased.

  • PDF

Skeletal relapse and dental change during intermaxillary fixation after mandibular setback (외과적 하악 후퇴술 후 악간고정기간 중의 골격성 재발과 치열의 변화)

  • Chang, Chong-On
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.457-466
    • /
    • 1999
  • It has been reported that skeletal relapse and dental change after mandibular setback do occur not only after intermaxillary fixation(IMF) removal but also during IMF The side effects of skeletal relapse during IMF have clinical importance because they can cause many Postoperative orthodontic Problems. Generally, the Prevention of solid union between segments, compensatory tooth movement, anterior openbite, etc. have been cited as the side effects of jaw displacement. The purpose of this study was to evaluate the skeletal relapse and dental change during IMF. The material consisted of 28 patients who were treated by BSSRO(bilateral sagittal split ramus osteotomy), wire osteosynthesis, IMF for correction of mandibular prognathism. Through cephalometric analysis, the amount and direction of surgical movement, skeletal relapse and dental change during IMF were measured. The correlation between surgical movement and skeletal relapse, between skeletal relapse and dental changes were evaluated. The following conclusions were obtained; 1. Distal segment was repositioned backward and upward, proximal segment showed clockwise rotation during surgery. 2. During ]m, anterior portion of distal segment was displaced backward and posterior portion was displaced upward. Proximal segment was displaced upward with forward movement of p-Go(gonion of proximal segment). Backward surgical movement of p-GO was significantly correlated with forward displacement of p-Go. 3. Overjet and overbite were not changed during IMF. The compensatory tooth movements during IMF were characterized by retroclination of upper incisors md retroclination, extrusion of lower incisors. These compensatory tooth movements had statistically significant correlation with upward displacement of d-Go (gonion of distal segment).

  • PDF

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement (임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구)

  • Choi, Yu-Sung;Kim, Eun-Kyung;Kim, Se-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the changes in bone density and reduction of time consumed for osteogenesis by $PostPlant^{TM}$ Calcium and to find out efficacy of $PostPlant^{TM}$ Calcium by comparing the group prescribed with $PostPlant^{TM}$ Calcium with the group without $PostPlant^{TM}$ Calcium prescription. Material and methods: The experimental group of 18 patients with 25 dental implant placement and the control group of 7 patients with 9 dental implant placement were randomly selected from the patients who visited prosthetic department of Dankook University Dental Hospital since July, 2006 (IRB Number ; 20060710). The experimental group was instructed to take $PostPlant^{TM}$ Calcium for 6 months after the implant surgery while the control group was instructed not to. Both experimental and control group were assigned for measurement using $Osstell^{TM}$ Mentor and $Periotest^{(R)}$ and radiographic examination was performed using specifically manufactured Aluminum Step Wedge. The results were compared and analyzed. Results: 1. According to the $Osstell^{TM}$ Mentor measurement, both the experimental and control group showed increase in values as time elapses and the experimental group showed significantly higher rate of increase (P < .05). 2. According to the $Periotest^{(R)}$ measurement, both the experimental and control group showed decrease in values as time elapses. In addition, greater decrease can be seen in the experimental group but no statistical significance was found. 3. By examining the radiographic images, both the experimental and control group showed tendency of increase in bone density. In addition, greater increase can be seen in the experimental group but no statistical significance was found. Conclusion: Clinically, taking $PostPlant^{TM}$ Calcium medicine for a long period of time after implant placement is expected for a better prognosis.

A COMPARATIVE STUDY ON THE THEMATIC DISTRIBUTION OF THE ARTICLES PUBLISHED IN THE JOURNAL OF THE AMERICAN ACADEMY OF PEDIATRIC DENTISTRY AND THE JAPANESE SOCIETY OF PEDIATRIC DENTISTRY (90년대 이후 미국과 일본 소아치과학회지 게재논문의 분야별 분포에 관한 비교 연구)

  • Yeom, Junng-Hyun;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.539-554
    • /
    • 2002
  • To identify the trend of pediatric dentistry in USA and Japan, closely related to Korean pediatric dentistry. The Japanese Journal of Pediatric Dentistry(JJPD) and The Journal of the American Academy of Pediatric Dentistry(PD) were reviewed. We collected the bibliographical data of the articles published in the two journals from 1991 to 2000. We analyzed thematic distributions and chronological changes, and then compare those of two groups. The following results were obtained: 1. The 869 articles were published in JJPD and 672 in PD. This was about 30% more in JJPD. 2. In both JJPD and PD, the case reports were a quarter of scientific articles in quantity. 3. The studies on the systemic diseases had the highest proportion in both JJPD and PD. The studies on the dental caries and restorative materials also had high proportion in both journals. 4. The studies on the sedation and biochemical survey had high proportion in PD when had low proportion in JJPD. To the contrary, The studies on the behavior science in JJPD were about double of those in PD. 5. There was no statistically significant difference in quantity between JJPD and PD in the studies on the dental caries, prevention of dental caries, community dental survey, conservative treatment, restorative materials, pulp treatment, diagnosis and treatment of malocclusion, oral pathology and minor surgery, local anesthesia and nerve tissue, traumatic injuries. 6. There was statistically significant increase in the studies on the dental equipment in JJPD and in those on restorative materials in PD. 7. There was statistically significant decrease in the studies on the prevention of dental caries and local anesthesia and nerve tissue in JJPD, and those on conservative treatment in PD.

  • PDF

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.