• Title/Summary/Keyword: Surface skin thickness

Search Result 137, Processing Time 0.023 seconds

Microstructural Morphology and Bending Performance Evaluation of Molded Microcomposites of Thermotropic LCP and PA6 (액정폴리머/폴리아미드6 미시복합재료의 내부구조 및 기계적 굽힘성능 평가)

  • ;Kiyoshi Takahashi
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.53-64
    • /
    • 1999
  • Microstructural morphology and bending strengths of moulded composites of thermotropic liquid crystalline polymer(LCP) and polyamide 6 (PA6) have been studied as a function of epoxy fraction. Injection-moulding of a composite plaque at a temperature below the melting point of the LCP fibrils generated a multi-layered structure: the surface skin layer with thickness of $65\;-\;120{\mu\textrm{m}}$ exhibiting a transverse orientation; the sub-skin layer with an orientation in the flow direction; the core layer with arc-curved flow patterns. The plaques containing epoxy 4.8vol% exhibited superior bending strength and large fracture strain. With an increase of epoxy fraction equal to and beyond 4.8vol%, geometry of LCP domains was changed from fibrillar shape to lamella-like one, which caused a shear-mode fracture. An analysis of the bending strength of the composite plaques by using a symmetric layered model beam suggested that addition of epoxy component altered not only the microstructural geometry but also the elastic moduli and strengths of the respective layers.

  • PDF

Analysis of Scattering Rays and Shielding Efficiency through Lead Shielding for 0.511 MeV Gamma Rays Based on Skin Dose (피부선량을 기준으로 0.511 MeV 감마선에 대한 납 차폐체의 산란선 및 차폐 효율 분석)

  • Jang, Dong-Gun;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • Radiation causes radiation hazards in the human body. In Korea, a case of radiation necrosis occurred in 2014. In this study, the scatter and shielding efficiency according to lead shielding were classified into epidermis and dermis for 0.511 MeV used in nuclear medicine. In this study, experiments were conducted using the slab phantom that represents calibration and the dose of human trunk. Experimental results showed that the shielding rate of 0.25 mmPb was 180% in the epidermis and 96% in the dermis. Shielding at 0.5mmPb showed shielding rates of 158%in the epidermis and 82% in the dermis. As a result of measuring the absorbed dose by subdividing the thickness of the dermis into 0.5 mm intervals, when the shielding was carried out at 0.25 mmPb, the dose appeared to be about 120% at 0.5 mm of the dermis surface, and the dose was decreased at the subsequent depth. Shielding at 0.5 mmPb, the dose appeared to be about 101% at the surface 0.5 mm, and the dose was measured to decrease at the subsequent depth. This result suggests that when lead aprons are actually used, the scattering rays would be sufficiently removed due to the spaces generated by the clothes and air, Therefore, the scattered ray generated from lead will not reach the human body. The ICRU defines the epidermis (0.07), in which the radiation-induced damage of the skin occurs, as the dose equivalent. If the radiation dose of the dermis is considered in addition, it will be helpful for the evaluation of the prognosis for radiation hazard of the skin.

Simulation Study of Solar Wind Interaction with Lunar Magnetic Fields

  • Choi, Cheong Rim;Dokgo, Kyunghwan;Woo, Chang Ho;Min, Kyoung Wook
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Particle-in-cell simulations were performed to understand the interaction of the solar wind with localized magnetic fields on the sunlit surface of the Moon. The results indicated a mini-magnetosphere was formed which had a thin magnetopause with the thickness of the electron skin depth. It was also found that the solar wind penetrated into the cavity of the magnetosphere intermittently rather than in a steady manner. The solar wind that moved around the magnetosphere was observed to hit the surface of the Moon, implying that it may be the cause of the lunar swirl formation on the surface.

Experimental Debonding Failure Behaviors of Composite Skin-Stiffener Bonded Specimens (복합재료 스킨-보강재 접합 시편의 파손 특성에 대한 시험 연구)

  • Kim, Kwang-Soo;An, Jae-Mo;Jang, Young-Soon;Yi, Yeong-Moo
    • Composites Research
    • /
    • v.20 no.6
    • /
    • pp.8-14
    • /
    • 2007
  • Debonding failure characteristics of the composite skin-stiffener specimens were experimentally investigated. The influences of bonding methods, types of stiffener shape and various secondary bonding parameters were evaluated. Present test results combined with the previous test results[1] showed that the failure displacement of the skin-stiffener specimens well evaluates the skin-stiffener debonding failure strength of the composite stiffened panels. The specimens with an open type stiffener had lower bending stiffness and larger failure displacement than those with a closed type stiffener. Secondary bonding and co-curing with adhesive had better failure strength than co-curing without adhesive film. Secondary bonded specimens failed by adhesive failure and co-cured specimens failed by delamination failure. As the bondline thickness was thinner, the skin-stiffener specimens had higher failure strength. The fillets had no influence on failure strength of the specimens. The influence of the surface roughness was shown according to types of stiffener shape.

A Study on the Resistance Welding of Metallic Sandwich Panel : Part 1 - Determination of Process Parameters (저항 용접을 이용한 금속 샌드위치 판재 접합에 관한 연구 : Part 1 - 공정변수의 선정)

  • Lee Sang-Min;Kim Jin-Beom;Na Suck-Joo
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.49-54
    • /
    • 2005
  • Inner Structured and Bonded(ISB) panel, a kind of metallic sandwich panel, consists of two thin skin plates bonded to a micro-patterned inner structure. Its overall thickness is $1\~3mm$and it has attractive properties such as ultra-lightweight, high efficiency in stiffness-to-weight and strength-to-weight ratio. In many previous studies, resistance welding, brazing and adhesive bonding are studied for joining the panel. However these methods did not consider productivity, but focused on structural characteristics of joined panels, so that the joining process is very complicated and expensive. In this paper, a new joining process with resistance welding is developed. Curved surface electrodes are used to consider the productivity and the stopper is used between electrodes during welding time to maintain the shape of inner structure. Welding time, gap of electrodes and distance between welding points are selected as the process parameters. By measuring the tensile load with respect to the variation of welding time and gap of electrodes, proper welding conditions are studied. Welding time is proper between 1.5-2.5cycle. If welding time is too long, then inner structures are damaged by overheating. Gap of electrode should be shorter than threshold value fur joint strength, when total thickness of inner structure and skin plate is 3.3mm, the threshold distance is 3.0mm.

A study on the boundary layer characteristics of TP620 hydrofoil in the steady state (정상상태인 박용 TP620 익형의 경계층 특성 연구)

  • 서봉록;김시영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.50-56
    • /
    • 1986
  • This report deals with a study on the boundary layer characteristics of TP620 hydrofoil in the steady state by using two dimensional boundary layer theory. On the basis of complex velocity and laminar and turbulent boundary layer theory, the author attempts to know some tendency by evaluating the performance characteristic values of TP620 hydrofoil working in a uniform flow. In deriving characteristic values, he calculates numerically velocity, momentum thickness, skin friction coefficient, shape factor, and displacement thickness on the TP620 hydrofoil working at each attack angle in a uniform flow. Applying this present numerical calculation using Thwaites' and Head's method, the results of boundary layer on the hydrofoil are shown to be influenced by surface velocity and attack angle.

  • PDF

Effect of Cnidium officinale Extract on Recovery Capability of Allergic Contact-Dermatitis in Rat (흰쥐의 알레르기성 접촉피부염의 회복에 미치는 천궁추출물의 영향)

  • Lim, Jae-Hwan;Park, Young-Mi;Kim, Jeong-Sook;Jeong, Hyung-Jin;Seo, Eul-Won
    • Korean Journal of Plant Resources
    • /
    • v.24 no.4
    • /
    • pp.430-437
    • /
    • 2011
  • The epidermal recovering-effects of the Cnidium officinale extract after inducing contact-dermatitis by 1-chloro-2,4-dinitrochlorobenzene (DNCB) showed by measuring thickness of skin, identifying IgE amounts in plasma, and activities of anti-oxidant enzymes using histochemical and biochemical methods. By three-time applications of the extract, morphological changes of dermatitis in impaired region were recovered dramatically and shape of skin surface and thickness of epidermis were restored to be normal. Also, lipid content was recovered to the level of normal state. We suggested that extract treatment lowered a hypersensitive reaction by decreasing of IgE level in blood and restored activities of superoxide dismutase and catalase. In conclusion, we proposed that C. officinale extract might be used as natural resources for treating effectively allergic contact-dermatitis.

Reconstruction of hand using anterolateral thigh fascial free flap (전외측대퇴근막 유리피판술을 이용한 수부의 재건)

  • Kim, Ki Wan;Kim, Jin Soo;Lee, Dong Chul;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2009
  • Purpose: The Provision of thin and pliable tissue and the adequate coverage of tendon - gliding surface is necessary for a soft tissue defect of the hand with exposure of bone, tendon and muscle. This report will discuss our experience with anterolateral thigh fascial free flap for the reconstruction of the soft tissue defect of the hand. Methods: Between February 2004 and August 2008, seven patients with full - thickness soft tissue defects of the hand were reconstructed by means of a composite anterolateral thigh fascial free flap. There were soft tissue defects associated with trauma (n=5), scar contracture (n=1) and necrosis due to ischemia (n=1). Flaps were harvested from the anterolateral thigh as adipofascial flaps with only a small sheet of fascia and fatty tissue above it. The fascia and the skin of the donor site was closed directly and delayed split - thickness skin graft was performed. Result: All flaps survived completely. The size of the transferred flap ranged from $2{\times}4cm$ to $5{\times}8cm$. Thin flap coverage was possible without secondary debulking operations. It left minimal donor site morbidity with a linear scar. In one case, the thigh muscle herniation in the donor site was developed. Conclusion: The anterolateral thigh fascial free flap provided thin and pliable tissue which can establish a tendon - gliding mechanism, minimal bulk, minimal donor site morbidity. The disadvantages of this technique were the need for a skin graft and the muscle herniation of donor site.

A Case of Isolated Collagenoma on the Finger (손가락에 발생한 고립성 교원종)

  • Yun, Young Mook;Kang, Nak Heon;Suh, Kwang Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.309-311
    • /
    • 2008
  • Purpose: Collagenoma is an intradermal harmatomatous collagen proliferation among connective tissue nevi of the skin. Although there are some reports of isolated collagenomas that occurred on the sole and the palm, collagenoms at the finger has not been reported in Korea. Methods: An 11-year-old girl presented with a growing mass on the distal interphalangeal joint of the left 5th finger. It was a skin-colored, oval and mild tender mass. There were no associated cutaneous or systemic abnormal findings. Results: The nodule, at the subcutaneous level on the distal phalanx, was completely removed by excision. Grossly it was covered with normal skin, and its surface was smooth having a definite margin with a size of $1.5{\times}1.2cm$. Histopathological examination, the epidermis showed to be normal, increased thickness of collagens arranged with a whirl formation was found in the dermis. No signs of cellular component increase were observed. Conclusion: Isolated collagenoma can be aroused as a solitary nodule in at any place of the body. We report a rare case of a female patient with an isolated finger collagenoma.

Surgical Management of Pyoderma Gangrenosum: A Case Report (괴저성 농피증의 수술적 치험례)

  • Seul, Chul Hwan;Kim, Bom Jin;Lee, Sung Joon;Kim, Sug Won;Chung, Yoon Kyu
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.135-138
    • /
    • 2005
  • Pyoderma gangrenosum(PG) is an uncommon cutaneous vascular disease that typically presents as a painful and destructive ulceration on the anterior surface of the legs. The etiology of PG is currently unknown. But, the association with many immunologic disorders and its clinical response to immunomodulating agents suggest an immune etiology. A common feature of patients with PG is the presence of pathergy(the induction of lesion following injury of the skin). The trauma of surgery can be sufficient to induce pathergy, thus paradoxically limiting the usefulness of surgical treatment of PG. For that reason, medical treatments have been commonly used, while surgical treatments have been regarded not suitable. However, the use of the classic systemic agents is limited by their side effects and contraindications. Moreover, the large, problematic ulcers take too long to heal with medical management only. We present our experience in closing large wounds with the goal of decreasing morbidity, drug side effects and hospital stay by combination of medical and surgical therapy(split thickness skin graft). And authors advocate that surgical management is not a contraindication and may be considered as a selective modality in treatment of PG.