• Title/Summary/Keyword: Surface plasmon resonance(SPR)

Search Result 126, Processing Time 0.019 seconds

Thiolated Protein A-functionalized Bimetallic Surface Plasmon Resonance Chip for Enhanced Determination of Amyloid Beta 42

  • Kim, Hyung Jin;Kim, Chang-Duk;Sohn, Young-Soo
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.379-383
    • /
    • 2019
  • The capability of detecting amyloid beta 42 ($A{\beta}42$), a biomarker of Alzheimer's disease, using a thiolated protein A-functionalized bimetallic surface plasmon resonance (SPR) chip was investigated. An optimized configuration of a bimetallic chip containing gold and silver was obtained through calculations in the intensity measurement mode. The surface of the SPR bimetallic chip was functionalized with thiolated protein A for the immobilization of $A{\beta}42$ antibody. The response of the thiolated protein A-functionalized bimetallic chip to $A{\beta}42$ in the concentration range of 50 to 1,000 pg/mL was linear. Compared to protein A without thiolation, the thiolated protein A resulted in greater sensitivity. Therefore, the thiolated protein A-functionalized bimetallic SPR chip can be used to detect very low concentrations of the biomarker for Alzheimer's disease.

The Construction of the SPR (Surface Plasmon Resonance) Sucrose Sensor (표면 플라즈몬 공명형 자당 센서의 제작)

  • Um, N.S.;Lee, S.M.;Hahm, S.H.;Koh, K.N.;Lee, S.H.;Kang, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.279-284
    • /
    • 1998
  • A surface plasmon resonance (SPR) sensor system for the determination of sucrose concentration was constructed with a gold thin film sensing chip. The properties of gold thin film are critical factors in exciting surface plasmon resonance phenomena. Therefore in the present paper, the fabrication conditions of gold thin film were investigated to optimize the SPR phenomena. The optimum thickness was obtained as $545{\AA}$ with $43.75^{\circ}$ resonance angle and good surface roughness limitation. about $3{\AA}$. The linear resonance angle shifts and rapid response were observed from the sucrose concentrations ranged from 0 to 40wt%.

  • PDF

Optical Characteristics of Bimetallic Silver-Gold Film Structure in Surface Plasmon Resonance Sensor Applications (표면 플라즈몬 공명 센서에서의 쌍금속 은-금 박막 구조의 광학 특성)

  • Gwon, Hyuk-Rok;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.156-160
    • /
    • 2007
  • Surface plasmon resonance(SPR) has been widely studied for biological and chemical sensing applications. The present study conducts numerical simulation for the single and bimetallic layer SPR configurations by using the multiple beam interference matrix(MBIM) method to investigate the influence of wave interference and complex refractive indices of materials on optical characteristics such as reflectance and optical phase shift which are used for sensing. First, calculated reflectances are compared with experimental data for validation. In addition, in the single film structures this study finds out the appropriate film thicknesses with minimum reflectance for cases of gold film and silver film. For a bimetallic silver-gold film structure, in particular, the bimetallic film thicknesses that has the minimum reflectance are found 36 nm for silver and 5 nm for gold. From the results, the use of phase shift would be useful compared to reflectance in determining the SPR configuration because the phase shift becomes more sensitive than reflectance.

Development of Surface Plasmon Resonance Immunosensor through Metal Ion Affinity and Mixed Self-Assembled Monolayer

  • Lee, Si-Ra;Sim, Sang-Jun;Park, Chul-Hwan;Gu, Man-Bock;Hwang, Un-Yeon;Yi, Jong-Heop;Oh, Byung-Keun;Lee, Jin-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.10
    • /
    • pp.1695-1700
    • /
    • 2008
  • An immunosensor based on surface plasmon resonance (SPR) with enhanced performance was developed through a mixed self-assembled monolayer. A mixture of 16-mercaptohexadecanic acid (16-MHA) and 1-undecanethiol with various molar ratios was self-assembled on gold (Au) surface and the carboxylic acid groups of 16-MHA were then coordinated to Zn ions by exposing the substrate to an ethanolic solution of $Zn(NO_3)_2\cdot 6H_2O$. The antibody was immobilized on the SPR surface by exposing the functionalized substrate to the desired solution of antibody in phosphate-buffered saline (PBS) molecules. The film formation in series was confirmed by SPR and atomic force microscopy (AFM). The functionalized surface was applied to develop an SPR immunosensor for detecting human serum albumin (HSA) and the estimated detection limit (DL) was 4.27 nM. The limit value concentration can be well measured between ill and healthy conditions.

Development of the Real-time Concentration Measurement Method for Evaporating Binary Mixture Droplet using Surface Plasmon Resonance Imaging (표면플라즈몬공명 가시화 장치를 이용한 증발하는 이종혼합물 액적의 실시간 농도 가시화 기법 개발)

  • Jeong, Chan Ho;Lee, Hyung Ju;Choi, Chang Kyoung;Lee, Hyoungsoon;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.212-218
    • /
    • 2021
  • The present study aims to develop the Surface Plasmon Resonance (SPR) imaging system facilitating the real-time measurement of the concentration of evaporating binary mixture droplet (BMD). We introduce the theoretical background of the SPR imaging technique and its methodology for concentration measurement. The SPR imaging system established in the present study consists of a LED light source, a polarizer, a lens, and a band pass filter for the collimated light of a 589 nm wavelength, and a CCD camera. Based on the Fresnel multiple-layer reflection theory, SPR imaging can capture the change of refractive index of evaporating BMD. For example, the present study exhibits the visualization process of ethylene glycol (EG)-water (W) BMD and measures real-time concentration change. Since the water component is more volatile than the ethylene glycol component, the refractive index of EG-W BMD varies with its mixture composition during BMD evaporation. We successfully measured the ethylene glycol concentration within the evaporating BMD by using SPR imaging.

Surface plasmon resonance sensor (표면 플라스몬 공명 센서의 제작)

  • Han, Won-Sik;Jung, Kyu-Jin;Lee, Sang-Won;Hong, Suk-Young;Lee, Young-Hoon;Hong, Tae-Kee
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 2006
  • The application and analysis of the interaction of various biomaterials including the concentration of biomaterials, thickness, and the ability of the detection of the analytical kinetic data of special biomaterials have been performed by SPR(surface plasmon resonance) sensor. To fabricate the scanning SPR, we designed data acquisition board and LabVIEW program for the personal computer to control the SPR sensor and collect the data from detector.

Optimal Design of Fiber-optic Surface Plasmon Resonance Sensors

  • Jung, Jae-Hoon;Kim, Min-Wook
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.55-58
    • /
    • 2007
  • We propose a systematic method for design of fiber-optic surface plasmon resonance (SPR) sensors. We used rigorous coupled wave analysis (RCWA) for analysis of the transmission spectrum, and the (1+1) evolution strategy (ES) was employed as an optimization tool. The simulation results show that the optimization method presented here is very useful in designing fiber-optic SPR sensor for strain and temperature measurement. This algorithm can be extended to another objective function with other weighting factors and optical parameters.

A Study on the Sensitivity of Surface Plasmon Resonance Sensor Chips with Various Material Configurations in Angle and Intensity Detection Modes (공명각 및 반사광 측정 모드에서 다양한 물질 구성의 표면 플라즈몬 공명 센서 칩의 민감도 특성)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.402-407
    • /
    • 2017
  • Characteristics of various material surface plasmon resonance (SPR) chips were investigated in angular interrogation mode and intensity interrogation mode. Among five metals, silver (Ag), gold (Au), copper (Cu), chromium (Cr) and titanium (Ti), three metals, Ag, Au and Cu were paid attention to since their characteristics can be easily analyzed in angular interrogation mode by investigating the change of their reflectance curves according to refractive index change from 1.331 to 1.335. Most of SPR chips with various configurations showed the similar property in angular interrogation mode. The application of the SPR chip made of Ag, Au and Cu or their combinations depends on their reflectance properties. In intensity interrogation mode, the operation range may be limited since the variation of the intensity was not linearly related to refractive index change ranging from 1.331 to 1.335. However, the SPR chip containing high ratio of Ag may be applicable to high sensitive detection due to their sharp reflectance curves in intensity interrogation mode.

Estimation of Sensitivity Enhancements of Material-Dependent Localized Surface Plasmon Resonance Sensor Using Nanowire Patterns (금속물질에 따른 나노구조를 이용한 국소 표면 플라즈몬 공명 센서 특성 분석)

  • Ahn, Heesang;Ahn, Dong-Gyu;Song, Yung Min;Kim, Kyujung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.363-369
    • /
    • 2016
  • We explored localized plasmonic field enhancements using nanowire patterns to improve the sensitivity of a surface plasmon resonance (SPR) sensor. Two different materials, gold and silver, were considered for sample materials. Gold and silver nanowire patterns were fabricated by electron beam lithography for experimental measurements. The wavelength SPR sensor was also designed for these experiments. The material-dependent field enhancements on nanowire patterns were first calculated based on Maxwell's equations. Resonance wavelength shifts were indicated as changes in the refractive index from 1.33 to 1.36. The SPR sensor with silver nanowire patterns showed a much larger resonance wavelength shift than the sensor with gold nanowire patterns, in good agreement with simulation results. These results suggest that silver nanowire patterns are more efficient than gold nanowire patterns, and could be used for sensitivity enhancements in situations where biocompatibility is not a consideration.

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.