• Title/Summary/Keyword: Surface Tension

Search Result 1,389, Processing Time 0.027 seconds

Surface Properties and Betergency of the Binary Surfactant Mixture (계면활성제 혼합용액의 계면특성 및 세척성에 관한 연구)

  • 심소희;박정희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.3
    • /
    • pp.632-640
    • /
    • 1997
  • Changes in surface properties and detergency of sunactant mixtures were investigated in order to study the optimum mixing ratio of anionic and nonionic surfactants by measuring surface tension, interfacial tension, suspendability, and emulsification as a Amction of mixing ratio. Also, surface tension and detergency of the surfactant mixtures were determined with the increase of water-hardness or temperature. The results were as follows: the addition of NPE to anionic surfactant solutions (LAS or SDS) by 0.1 mole fraction remarkably decreased surface tension. NPE (n=15)/anionic surfactant mixtures showed a synergistic effect in lowering interfacial tension and emulsification, but NPE (n=7.5)/anionic surfactant mixtures did not. In suspension stability, however, synergism appeared when LAS or 505 was mixed with both of NPE's. With respect to the hydrophile of NPE, NPE (n=15) was more effective than NPE (n=i.5) in improving suspension stability. Detergency of LAS/NPE mixture changed almost linearly with mixing ratio, but that of SDS/NPE mixture increased remarkably by the addition of 0.1 or 0.2 mole fraction of NPE at all temperatures. As the temperature increased, surface tension of surfactant mixtures decreased and detergency was improved, but their synergistic effect decreased. In hard water, the mixtures showed better detergency than single surfactuant solutions.

  • PDF

Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement (막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토)

  • Jin, Sang-Wook;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

Estimation of surface tension of liquid alloys under different oxygen partial pressure

  • Min, Sun-Gi;Lee, Jun-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.101-101
    • /
    • 2008
  • The effect of oxygen partial pressure on the surface tension data of liquid alloys was investigated by means of comparing the calculated data and the measured one. Two binary alloy systems were chosen to observe the dependence of oxygen adsorption behavior on different oxygen partial pressures. It was found that the difference between the computed values and the experimental of the surface tension was within the range of maximum 10%.

  • PDF

Wettability of Lubricant-Impregnated Electroplated Zinc Surface with Nanostructure (윤활유가 침지된 나노구조 전기아연도금층의 젖음성)

  • Jung, Haechang;Kim, Wang Ryeol;Jeong, Chanyoung;Lee, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.1
    • /
    • pp.37-42
    • /
    • 2019
  • Electrodeposited zinc layer is widely used as a sacrificial anode for a corrosion protection of steel. In this study, we modified the surface of electrodeposited zinc to have a hydrophobicity, which shows various advanced functionalities, such as anti-corrosion, anti-biofouling, anti-icing and self-cleaning, due to its repellency to liquids. Superhydrophobicity was realized on electrodeposited zinc layer with a hydrothermal treatment, creating nanostructures on the surface, and following Teflon coating. The superhydrophobic surface shows a great repellency to water with high surface tension, while liquid droplets with low surface tension easily adhered on the superhydrophobic surface. However, immiscible lubricant-impregnated superhydrophobic surface shows a great repellency to various liquids, regardless of their surface tension. Therefore, it is expected that the lubricant-impregnated surface can be an alternative of superhydrophobic surface, which have a drawback for some liquids with a low surface tension.

Preparation and Characterization of Surface Energy of BPDA-BAPP Polyimide

  • Kim, Kyung-Hoe;Kim, Yong-Gwon;Kwon, Young-Hwan
    • Macromolecular Research
    • /
    • v.17 no.6
    • /
    • pp.388-396
    • /
    • 2009
  • The surface properties (water sorption and repellency, adhesion) are closely related to the surface tension of polymer solids. The critical surface tension (${\gamma}_c$) and surface tension (${\gamma}_s$) of a polymer solid were estimated by the contact angle method by our quantitative imaging system. BPDA (3,3',4,4'-biphenyl tetracarboxylic dianhydride)-BAPP (1,3-Bis(4-aminophenoxy) propane) polyimide was successfully synthesized. The ${\gamma}_c$ values were analyzed by a Zisman plot, a Young-$Dupr\acute{e}$-Good-Girifalco plot, and a log ($1+cos{\theta}$) vs log ${\gamma}_L$ plot. The ${\gamma}_s$ value of BPDA-BAPE polyimide was evaluated using the geometric mean equation and our multiple regression analysis. The calculated values of ${{\gamma}_s^d$ (a dispersion component), ${{\gamma}_s^p$ (a polar component), ${{\gamma}_s^h$ (a hydrogen bonding component), and ${\gamma}_s$ were 30.79, 9.32, 0.20, and 40.31 $mN{\cdot}m^{-1}$, respectively. The ${\gamma}_s$ of BPDA-BAPP polyimide containing both a methylene group and an ether group was larger than that of the polyimide containing only a methylene group.

The Effect of the Surface Tension of Contaminants on Tracking Ageing of Polymeric Composites (오손액의 표면장력이 폴리머 복합재의 트래킹 열화에 미치는 영향)

  • 조한구;천종욱;이운용;한동희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.435-438
    • /
    • 2002
  • In this paper, the effect of surface tension, wettability, flow rate of contaminants with varying surfactant content and frequency of applied voltage on the tracking breakdown of epoxy insulating materials were investigated. As the flow rate of contaminant is increased, the surface resistivity is decreased, and the leakage current is increased, the time to tracking breakdown is decreased. It is found that time to tracking breakdown depends on the surface tension of contaminant, that is difference of wettability And as the frequency of applied voltage is increased, time to tracking breakdown decreased.

  • PDF

A Study on Elevated Temperature Fatigue Crack Growth Using Round Bar Specimen with a Surface Crack (표면균열을 갖는 원형봉재 시편을 이용한 고온 피로균열성장 연구)

  • So, Tae-Won;Yun, Gi-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3415-3423
    • /
    • 1996
  • The compact tension specimen geometry has been widely used for measuring fatigue crack growth rates at elevated temperature when the fatigue load is under tension/tension condition. However, most of the elevated temperature components which have significant crack growth life experience fatigue load under tension/compression conditions. Thus test techniques are required since the compact tension specimen cannot be used for tension/compression loading. In this paper, a simplified test procedure for measureing fatigue crack growth rates is proposed, which employs a round bar specimen with a small surface crack. Fatigue crack growth rates under tension/ tension loading conditions at elevated temperature were measured according to the proposed procedure and compared with those previously measured by C/(T) specimens. Since both the measured crack growth rates were comparable, the fatigue crack growth rates under tension/ compression load can be reliably measured by the proposed procedure. For monitoring crack depth. DC electric potential method is employed and an optimal probe location and current input conditions were proposed.

The Surface Activities of Surfactant Mixtures (혼합 개면활성제의 개면활성에 관한 연구)

  • 정혜원
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.348-354
    • /
    • 1994
  • The changes of surface activities in the aquaous solutions of mixed surfactants composed of linear sodium dodecylbenznesulfoate (LAS), polyoxyethylene nonyl phenylether (PE, EO=10) and polyethylene glycol monolauryl ether (LE, EO=25) have been studied. Addition of nonionic surfactants to LAS reduces the surface tension, especially at the lower concentration than cmc. The interfacial tension of olive oil/LAS was lower than the other surfactant solutions. The removal of triolein from cotton fabrics by nonionic surfactants and mixtures is higher than by LAS. The addition of NaCI to surfactant solutions even though reduces surface tension smaller but enthances oil removal more than that of $CaCl_2$.

  • PDF

Effect of X-Irradiation in Vitro on the Pulmonary Surfactant in Rabbits (In Vitro X선조사(線照射)가 가토폐포표면(家兎肺胞表面) 활성물질(活性物質)에 미치는 영향(影響))

  • Cho, Joong-Hwan;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.5 no.1
    • /
    • pp.51-58
    • /
    • 1971
  • In an attempt to further clarify the effect of X·irradiation on the activity of surfactant in rabbits, X-ray in dose of 900r was irradiated to the lung tissues of rabbits in vitro. Tension-area diagram of the lung extract was recorded automatically by a modified Langmuir-Wilhelmy balance with a synchronized recording system designed in this department. The surface tension of the lung extract was measured at 1,3,5,24 and 48 hours post-irradiation, and the results were compared with the non·irradiated normal group. The result$ thus obtained are summarized as follows: I The maximal surface tension, minimal surface tension, width of the tension·area diagram at the surface area of 40% in the lung extract and stability index of the normal rabbit long extract were 40.73 dynes/cm, 8.96 dynes/cm, 20.71 dynes/cm and 1.28, respectively. II. When 900r of X-ray was irradiated to the lung in vitro, 1) The maximal and minimal surface tensions did not differ noticeably from the normal at 1,3, and 5 post-irradiation hours, but the minimal surface tension increased significantly at 24 and 48 hours Post-irradiation. 2) The width of the tension area at the surface area of 40% showed a tendency of decrease throughout the experiment. 3) The stability index showed no significant change at 1,3 and 5 post-irradiation hours,but at 24 and 48 hours post-irradiation a significant decrease was observed comparing with the control. III. Activity of surfactant was significantly depressed by X·irradiation in vitro especially at 24 and 48 hours post-irradiation.

  • PDF

The Effects of Surface Shear Viscosity and Surface Tension on a Columnar Vortex Interacting with a Free Surface (자유표면과 반응하는 수직와류에 대한 표면점성계수와 표면장력의 영향)

  • Kim Kyung-Hoon;Sohn Kwon;Kim Seok-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.51-57
    • /
    • 2005
  • Vertices terminating at free surface have been investigated extensively. Most of investigations, however, are focused on surface parallel vortices and little has been known about surface normal vortex or columnar vortex. Visualized experimental results utilizing LIF technique are discussed fur the purpose of characterization of columnar vortex interacting with a clean and a contaminated free surfaces and a solid body interface in the present investigation. The results reveal that surface tension changes due to surface contamination although bulk viscosity remains constant and eventually the behavior of a columnar vortex interacting with a contaminated free surface and a solid body interface are totally different from the clean free surface case.

  • PDF