• 제목/요약/키워드: Surface Measurement

검색결과 4,981건 처리시간 0.032초

비전을 이용한 곡면변형률 측정의 정확도 및 정밀도 향상에 관한 연구 (A Study on the Improvement of Accuracy and Precision in the Vision-Based Surface-Strain Measurement)

  • 김두수;김형종
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.294-305
    • /
    • 1999
  • A vision-based surface-strain measurement system has been still improved since the authors devel-oped the first version of it. New algorithms for the subpixel measurement and surface smoothing are introduced to improve the accuracy and precision in the present study. The effects of these algorithms are investigated by error analysis. And the equations required to calculate 3D surface-strain of a shell element are derived from the shape function of a linear solid finite-element. The influences of external factors on the measurement error are also examined, and several trials are made to obtain possible optimal condition which may minimize the error.

  • PDF

원통 축 방향의 표면거칠기 측정을 위한 시료의 자세 보정 (Orientation Correction of a Cylinder for Surface-Profile Measurement)

  • 조남규
    • 한국생산제조학회지
    • /
    • 제5권4호
    • /
    • pp.108-120
    • /
    • 1996
  • A new technique and theory are proposed which correct orientation of a cylinder to perform a reliable measurement of the surface profile. We analyze characteristics of machined surfaces, e.g., ground, lapped and turned surfaces. Based upon the results. the optimum correction technique is derived by the statistical method. To verify the techinques, measurements are carried out by using the contact stylus profilometer on a controllable table. The measurement shows that surface information of cylinders can be acquired with high accuracy.

  • PDF

광섬유센서에 의한 간이 비접촉 표면조도 측정기의 개발 (Development of the Handy Non-contact Surface Roughness Measurement Device by using the Optical Fiber Sensor)

  • 홍준희
    • 대한공업교육학회지
    • /
    • 제34권2호
    • /
    • pp.346-362
    • /
    • 2009
  • 본 연구는 광섬유센서를 이용하여 표면조도의 간이 비접촉 측정기를 개발하는데 목적이 있다. 광섬유 센서의 장점은 우수한 고속 응답성, 자기의 무영향, 제작의 편이성이다. 광섬유센서 표면조도 측정 원리는 측정물의 표면조도에 따라 반사되는 광의 세기와 기지의 표면조도 값을 일대일 대응시키는 것이다. 반사광의 세기는 센서 프로브로부터 표면까지의 거리와 표면조도에 따른 반사한계각에 따라 결정되는데 본 연구에서는 표면까지의 거리를 일정하게 하여 표면조도에 따른 반사한계각만을 가지고 표면조도가 결정되도록 측정 프로브를 제작하였다. 측정 시스템은 발광부, 수광부과 신호처리부로 구성되었다. 이 실험에서 사용된 표준 측정 재료는 SM45C, STS303과 Al60이었다. 연구결과 첫째, 재료에 따른 표면조도와 센서출력의 상관관계로부터 근사표면조도식을 도출하고 임의 가공된 시료의 표면조도 측정을 통해 근사표면조도식이 유효함을 입증하였다. 둘째, 실제 제작한 간이 광섬유센서 표면조도 측정기가 유용함을 입증하였다.

화상처리법을 이용한 곡면변형률 측정에 관한 연구 (A Study on the Measurement of Surface Strain Using the Image Processing Technique)

  • 김영수;김형종
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 춘계학술대회논문집
    • /
    • pp.213-216
    • /
    • 1997
  • The measurement of 3D surface strain using the image processing method is another approach for strain measurement. The advantage of this method is that strains at several points included in a captured image can be obtained automatically from only one process. In this study, the whole process of automated surface strain measurement is presented. The strain distribution on a LDH specimen is illustrated as a result of the trial to develope an automated strain measurement system.

  • PDF

이중관 구조 박막형 순간온도 프로브의 응답성에 관한 연구 (A Study on the Responsibility of Thin film instantaneous surface temperature probe of a Dual-pipe structure)

  • 최석렬;박경석
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.237-242
    • /
    • 2003
  • The measurement study of instantaneous temperature at combustion chamber wall and the temperature of combustion gas has been under lots of research and development to conclude the temperature process in internal combustion engine for combustion characteristics analysis. The measurement with fast responsibility should be used for temperature measurement inside combustion chamber wall since temperature of wall changes, due to the various gas temperature, irregularly during the combustion. Therefore, thin film instantaneous surface temperature probe, which characterizes the fastest and the most accurate responsibility among contact typed temperature measurement, was used for the experiments. This new thin film instantaneous surface temperature probe improved the problems of noise and durability. The optimal coating thickness of thin film instantaneous surface temperature probe was proven to be $10{\mu}m$ for the best responsibility and durability. It also allowed the stable temperature measurement be taken up to $1,200^{\circ}C$ and proven to be read possibly from the combustion chamber wall.

  • PDF

광 간섭계를 이용한 표면 및 위상지도 분석에 관한 연구 (A Study on the surface and analysis of phase map using optical interferometer)

  • 박준도;신수용;황보승;강용철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.436-437
    • /
    • 2005
  • 3-dimension object's feature measurement is used several industrial field to produce for examination of demanded high quality products by using optical measurement method. 3-dimension object's feature measurement is separated surface scanning and surface non-scanning. In this research, we illuminated interfero-pattern to object, it was constructed with Michelson interferometer by using laser is one of surface non-scanning method. And we extracted phase-map, it is one of featural measurement analysis of 3-dimensional object by using a phase shifting theory.

  • PDF

CAD/CAM/CAI 통합에 기초한 자유곡면의 On-Machine Measurement : I. 측정오차 모델링 (On-Machine Measurement of Sculptured Surfaces Based on CAD/CAM/CAI Integration : I. Measurement Error Modeling)

  • 조명우;이세희;서태일
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.172-181
    • /
    • 1999
  • The objective of this research is to develop a measurement error model for sculptured surfaces in On-Machine Measurement (OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC Machining center is derived using a 4${\times}$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the scupltured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also, the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-step measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

음향파워 측정 시 오차에 대한 고찰 (A Study on the Errors at the Measurement of Sound Power)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.

물체표면의 3차원 정밀형상측정을 위한 공초점 현미경에 관한 연구 (A Study on Confocal Microscope for A Precise 3-Dimensional Surface Measurement)

  • 송대호;안중근;강영준;채희창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • In modem industry, the accuracy and the surface-finish requirements for machined parts have been becoming ever more stringent. Optical method in measurements is playing an important role in vibration measurement, crack and defect detection and surface topography with the advent of opto-mechatronics. In this study, the principle of the general confocal microscope is introduced for surface measurement, and the advanced confocal microscope that has better measuring speed than the traditional confocal microscope is developed. A study on improving the resolution of the advanced confocal microscope is followed. Finally, Software for data acquisition and analysis of various parameters in surface geometrical features has been developed.

  • PDF

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • 제29권2호
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF