• Title/Summary/Keyword: Supply valve

Search Result 292, Processing Time 0.03 seconds

Development of Prototype Fill/Drain Valve for Supply of Satellite Propellant (인공위성 추진제 공급용 Fill/Drain 밸브 시제품 개발)

  • Kim, Su-Kyum;Yu, Myoung-Jong;Lee, Kyun-Ho;Choi, Joon-Min;Jang, Ki-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.26-31
    • /
    • 2006
  • Through the KOMPSAT program, Koreanization of thruster have been carried out successfully, but there are still many difficulties in Koreanization of most core parts of propulsion system. Because the development of core parts is essential to participate in the advanced nations, KARI has carried out development of Fill/Drain valve for propellant/pressurant supply of satellite, which has high possibilities to be koreanized, with Hanwha Corp.. This paper summarizes overall processes of development including design, manufacturing and test, and finally 4 sets of modules were successfully made. Also the satisfaction of performance requirements are verified through performance tests.

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System (HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로)

  • Jung, Jae-Hun;Cho, Han-Je;Goo, Beob-Jin;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

Characteristic Analysis and experiment of the Low Power Consumption type Micro Valve (초절전형 마이크로 밸브 특성해석 및 실험)

  • Kim, D.S.;Park, S.W.;Kim, H.S.;Yoo, J.S.;Lee, W.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.876-881
    • /
    • 2004
  • In this study, A special quality analysis and experiment for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(2.4N) is exerted enough to move poppet with 0.3mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke. Under the condition of poppet stroke smaller than about 0.8mm, dynamic pressure acts to poppet wall up to supply pressure level. But, that is decreasing to 40% when poppet stroke is 0.8mm.

  • PDF

The Experimental Study of Water Hammer by Valve Closure in Water Supply Piping System (단순 급수관로에서의 워터 햄머 현상에 관한 연구)

  • 이용화;유지오;박효석;김영호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.697-702
    • /
    • 2000
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening copper piping system. Experiments were conducted under the following conditions : initial pressure 1~5 bar, flow velocity 0.6~3.0 m/s and water temperature $20^{\circ}C$ . Results indicated that the peak pressure generated by quick valve closure reached Joukowsky's value. And we also found that the maximum pressure rise and the pressure history were depended on not only closing time but also flow velocity.

  • PDF

Auto Flow Rate Regulating System Synchronized with Room Control (난방시 실별 연동형 세대자동유량제어 시스템)

  • Kim, Young-Kyun;Kim, Nam-Gun;Seo, Bum-Suk
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.77-82
    • /
    • 2009
  • If we can supply accurate minute flow rate to the households, we can solve many problems that are occurring in consequences of uncontrolled flow rate for the households. Therefore, this paper presents an innovative solution to the source of the problems by illustrating how we can control the flow rate to the household. This paper proves such problems even can be solved in a case when there is a room turned off the heating.

  • PDF

Analysis and Design of the Low Power Consumption type Micro Valve (초절전형 마이크로 밸브 해석 및 설계)

  • Kim D.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.2
    • /
    • pp.15-19
    • /
    • 2004
  • In this study, Design and simulation for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(6.8N) is exerted enough to move poppet with 0.438mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke. Under the condition of poppet stroke smaller than about 0.4mm, dynamic pressure acts to poppet wall up to supply pressure level. But, that is decreasing to 40% when poppet stroke is 0.8mm.

  • PDF

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.4
    • /
    • pp.15-22
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

Development of the Rack-Bar Type Sluice Gate Applying the Hydrostatic Transmission (정유압식 래크바형 수문권양기의 개발)

  • Lee, Seong-Rae
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.86-92
    • /
    • 2010
  • The typical hydraulic hoisting system of the rack-bar type sluice gate is composed of a hydraulic supply unit using an uni-directional pump, a direction control valve, a hydraulic motor, a counter balance valve, and flow control valves. Here, the hydrostatic transmission is applied to the hoisting system of rack-bar type sluice gate to simplify the operation of gate such that the upward and downward direction of gate is simply controlled by the direction of pump rotation. The new hydraulic hoisting system is composed of a bi-directional pump, a hydraulic motor, a counter balance valve, two check valves, two pilot-operated check valves, two relief valves and a shuttle valve. The characteristics of a suggested system are analyzed by computer simulations and experiments.

  • PDF

Performance Test Circuit for a Valve of MMC Based HVDC Power Converter (MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로)

  • Chi-Hwan Bae;Kwang-Rae Jo;Hak-Soo Kim;Eui-Cheol Nho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.