• 제목/요약/키워드: Superconducting Fault Current Limiter

검색결과 493건 처리시간 0.024초

선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구 (A study on operating properties of superconducting fault current limiter in the line-to-line fault)

  • 최효상;현옥배;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

저항형 초전도 한류기에서의 퀀치 전파 (Quench propagation in resistive SFCL)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • 한국전기전자재료학회논문지
    • /
    • 제13권4호
    • /
    • pp.337-342
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters based on YB $a_{2}$/C $u_{3}$/ $O_{7}$ thin films and investigated their quench propagation characteristics. The YB $a_{2}$/C $u_{3}$/ $O_{7}$ films was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The quench was concluded to start locally and propagates until completed. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time depended strongly on potential fault current amplitude and not significantly on fault angle which indicates that the quench propagation speed is affected more by heat dissipation rate than by fault current increase rate. The quench completion time was 1 msec at the fault current of 65 $A_{peak/{\ak}}$.

  • PDF

초전도고장전류제한기의 고장전류억제효과와 동작파라메타 설정방법에 대한고찰 (On Fault Current Limitering and Design Method of the Specific Parameter of Superconducting Fault Current Limiter)

  • 홍원표;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.972-974
    • /
    • 1997
  • Design & Operation of power system for meeting increase of electric Power demand is becoming more difficult and complex. One of reasons is increase of fault current. As one of the most effective methods for suppressing the fault current installation of SFCL is expected. These paper describes a method of fault analyses of power system with SFCLs, and also discusses determination of specification of SFCLs, effects of limiting the fault current due to SFCLs by use of the model system of two - bus electric power system with single transmission lines.

  • PDF

Cooling Characteristics of Sub-cooled Nitrogen Cryogenic System for 6.6kV/200A Inductive Fault Current Limiter

  • Hyoungku Kang;Bae, Duck-Kweon;Ahn, Min-Cheol;Kim, Hyung-Jin;Chang, Ho-Myung;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.57-61
    • /
    • 2003
  • In this investigation, the 6.6kV/200A Inductive Superconducting Fault Current Limiter (SFCL) was designed and fabricated. The type of DC reactor for Inductive SFCL was determined as solenoid type during the period of $1${st}$ year research. The 5 bobbins for DC reactor were fabricated and each bobbin was wound with 4 stacked High-Tc superconducting (HTS) tapes and the 5 bobbins were connected in series. The critical current and inductance of DC reactor were simulated by Finite Element method (FEM) and compared with the measured results. The characteristics of DC reactor were enhanced in sub-cooled nitrogen system rather than in liquid nitrogen system. The procedures to accomplish the sub-cooled nitrogen system and the experimental results were introduced in detail. Moreover, the design of sub-cooled nitrogen cryogenic system for next year research was introduced in brief.

3상 단락사고에 대한 저항형과 유도형 한류기의 동작특성 (Operating properties of the resistive and inductive SFCL with the three-phase fault)

  • 최효상;현옥배;김상준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.209-212
    • /
    • 1999
  • We studied the operating properties of resistive and inductive SFCLS with 100 $\Omega$ of quench impedance for a three-phase-fault in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$ , 45$^{\circ}$ , and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 16 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 11 kA, but with 3-4 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권5호
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.

배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발 (Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application)

  • 박동근;석복열;고태국;강형구
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

변압기를 이용한 저항형 고온초전도 전류제한기의 한류 특성 (Fault Current Limiting Characteristics of Resistive Type SFCL using Transformer)

  • 임성훈;최효상;고석철;이종화;강형곤;한병성
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.288-290
    • /
    • 2003
  • The transformer is expected to be an essential component of resistive type superconducting fault current limiter (SFCL) for both the increase of voltage ratings in SFCL and the simultaneous quench due to different critical current between HTSC elements. However, for the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for operation of SFCL with consideration for the magnetization characteristics are required. In this paper, the fault current limiting characteristics related with the magnetization ones were investigated through the variation of the ratio of the number of turns in the 1st and the 2nd windings. The proper design condition with variation of the number of turns to make the effective fault current limiting operation could be determined.

  • PDF

2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성 (Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings)

  • 황종선;조용선;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

저항형 초전도 한류기에서의 퀀치 전파 (Quench propagationin resistive SFCL)

  • 김혜림;현옥배;최효상;황시돌;김상준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 1999
  • We fabricated resistive superconducting fault current lmiters based on YBa$_2$Cu$_3$O$_{7}$ thin films and investigated their quench propagation characteristics. The YBa$_2$Cu$_3$O$_{7}$ film was coated with a gold layer and patterned into 1 mm wide meander lines by photolithography. The limiters were tested with simulated fault currents of various fault angles and amplitudes. The quench propagation characteristics were explained based on the heat transfer within the film as well as between the film and the surrounding liquid nitrogen. The quench completion time strongly depended on the potential fault current. It was 1 msec at the peak fault current of 76 A/peak/ and corresponding quench propagation speed was 43 m/sec (film cross section: 4 x 10$^{-6}$ $\textrm{cm}^2$).

  • PDF