• 제목/요약/키워드: Suction test

Search Result 305, Processing Time 0.027 seconds

Development of a Potable Skimmer(II) - Fabrication and Performance Test of an Air Suction Skimmer (휴대용 유출기름회수기의 개발(II) - 공기흡입회수기의 제작과 성능시험)

  • 박외철
    • Journal of Environmental Science International
    • /
    • v.3 no.2
    • /
    • pp.177-184
    • /
    • 1994
  • An air suction skimmer was selected as a potable skimmer to be developed among the many reviewed skimmers because of its advantages such as simple structure, excellent transportability, and easy deployment. A prototype of the skimmer was fabricated. It was shown that the skimmer operated by a commercial vacuum cleaner has good performance. The maximum suction rate of water and the maximum suction head were 18$m^3$/hr and 2.7m, respectively.

  • PDF

The Impact of Different Endotracheal Suction Methods on Respiratory Function: Normal Saline with Chest Vibration vs Normal Saline with Expectorant Mixture (기관내 흡인방법에 따른 호흡기능의 차이)

  • Cho, Hyo-Im;Lee, Young-Whee;Ham, Ok-Kyung;Lim, Ji-Young
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.2
    • /
    • pp.209-218
    • /
    • 2008
  • Purpose: Regarding the respiratory function of patients with an artificial airway, this study compared the effects between normal saline with chest vibration and normal saline with expectorant mixture, administered before endotracheal suction. Methods: The study was conducted in the ICUs of one university hospital located in Incheon. The experimental group I received normal saline with chest vibration administered before endotracheal suction while the experimental group II received normal saline with expectorant mixture administered before endotracheal suction. For respiratory function, $PaO_2$, $PaCO_2$, and $O_2$ saturation were measured by ABGA at 3 minutes after endotracheal suction for both pre-test and post-test. Results: The two groups were not different significantly regarding $PaO_2$ level and $O_2$ saturation after the treatments, while, the experimental group II had lower $PaCO_2$ level than the experimental group I after the treatments (t = 2.075, p = .042). For experimental group II, post-test score of $PaCO_2$ level was significantly lower than that of the pre-test score (t = 1.842, p = .075). Conclusion: The administration of normal saline with expectorant mixture before endotracheal suction reduced $PaCO_2$ level and improved the respiratory function.

  • PDF

Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement (고유진동수 기반 석션기초의 지반구속효과 분석)

  • Ryu, Moo Sung;Lee, Jun Shin;Lee, Jong Hwa;Seo, Yun Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

Accumulated Rotations of Suction Bucket Foundations under Long-term Cyclic Loads in Dry Sandy Ground (건조 사질토 지반에 설치된 석션 버켓기초의 장기 반복하중에 의한 누적회전각 산정)

  • Lee, Si-Hoon;Choi, Changho;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.12
    • /
    • pp.69-78
    • /
    • 2016
  • A suction bucket foundation has been considered to be a potential foundation type for offshore wind turbines. A suction bucket foundation is usually installed in soft soil, so the accumulated displacement of the foundation may occur under long-term cyclic loads. In this study, a series of 1-g model tests were performed to analyze the accumulated rotation of suction bucket foundations under long-term cyclic horizontal loads. The dry model ground was prepared to have two different soil densities by air-pluviation method. The model tests were performed varying the embedment depth of the suction bucket, the soil density, and the amplitude of cyclic load. A one-way horizontal cyclic load was applied over $10^4$ cycles. Test results showed that the accumulated rotation of the suction bucket foundation increased with the increase in the number of cycles and load magnitudes. Based on the model test results, a new equation was proposed to evaluate the accumulated rotation of the suction bucket foundations in dry sandy ground under long-term cyclic horizontal loads.

Hydro-mechanical behavior of compacted silt over a wide suction range

  • Chen, Bo;Ding, Xiuheng;Gao, You;Sun, De'an;Yu, Haihao
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.237-244
    • /
    • 2020
  • To achieve a wide suction range, the low suction was imposed on compacted silt specimens by the axis translation technique and the high suction was imposed by the vapor equilibrium technique with saturated salt solutions. Firstly, the results of soil water retention tests on compacted silt show that the soil water retention curves in terms of gravimetric water content versus suction relation are independent of the dry density or void ratio in a high suction range. Therefore, triaxial tests on compacted silt with constant water content at high suctions can be considered as that with constant suction. Secondly, the results of triaxial shear tests on unsaturated compacted silt with the initial void ratio of about 0.75 show a strain-hardening behavior with a slightly shear contraction and then strain-softening behavior with an obviously dilation. As the imposed suction increases, the shear strength increases up to a peak value and then decreases when the suction is beyond a special value corresponding to the peak shear strength. The residual strength increases to fair value and those at high suctions are almost independent of imposed suctions. In addition, the contribution of suction to the strength of compacted silt would not diminish even in a high suction range.

A Experimental Study on the Performance of an Axial-Type Suction-Blowing Fan (축류형 흡배송 송풍기의 성능에 관한 실험적연구)

  • Choi, Hyoung-Jun;Park, Young-Ha;Ahn, Kook-Young;Cho, Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.19-24
    • /
    • 2011
  • An experimental study was conducted to examine the effectiveness of a suction-blowing fan that could not only remove polluted air by suction but also create the air-curtain by blowing. In order to create the air-curtain, rotors were installed on the surface of the shroud. These blows fresh air into the polluted region. The fresh air is spouted backward 45o on the basis of the axial direction using a double-ducted bellmouth. In the same suction operating condition, the suction region was extended by increasing the blowing velocity. However, the increasing rate of suction region was reduced when the blowing velocity was increased steadily. Thus, an efficient blowing velocity should be determined depending on the suction operating condition. In addition, the blowing requires additional input power. In a fixed suction operating condition, the input power was linearly increased in proportion to the blowing flowrate. When the suction-blowing fan was operated in the same input power as the suction fan, the suction region was increased more than 30% based on the 0.6m/sec velocity.

Effects of Tracheal Suction and Method of Bronchodilator Inhalation on Vital Signs and Pulmonary functions in Patients with Open Heart Surgery(OHS) (심장수술 환아에게 기도흡인과 기관지 확장제의 투여 방법이 활력징후 및 폐기능에 미치는 효과)

  • Song Hyo-Sook;Jun Tae-Gook;Park Pyo-Won;Kim Kyoung-Eun;Chung Ji-Hye
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.10 no.1
    • /
    • pp.96-107
    • /
    • 2003
  • Objective: The purpose of this study was to identify the effects of tracheal suction and the effects of different methods of bronchodilator inhalation (Ultrasonic nebulizer: MDI puff, MDI puff with spacer) in VSD surgery patients. Material & Method: From June 2001 to March 2002, sixty consecutive patients were randomly assigned to a control group (n= 15), ultrasonic nebulizer group (n=15), metered dose inhalation (MDI) puff group (n=15) and MDI with spacer group (n=15). Vital signs (HR, BP, CVP), ABGA and pulmonary functions were measured before suction (baseline for suction), after suction, 15 minutes after suction (base of bronchodilator inhalation), 30 minutes after bronchodilator inhalation, and 2 hours after bronchodilator inhalation. Stastistical analysis was performed using SPSS software. Repeated measure ANOVA was used to examine the effects of tracheal suction. One way ANOVA with Bonferroni's correction and multiple range test (the least significant difference test) were used to examine the effects of albuterol inhalation. Result: 1. Heart .ate increased significantly immediately after suction (p<.01) and recovered 15 minutes after suction. 2. $PaO_2$ and PH decreased significantly immediately after suction (p<.05) and $PaO_2$ recovered 15 minutes after suction. $PaCO_2$ increased immediately after suction and significantly 15 minutes after suction (p<.01). But changes in vital signs and ABGA were within the normal range. 3. Tidal volume decreased significantly 15 minutes after suction (p<.05). 4. Changes of HR and tidal volume were greater in the nebuizer group compared to the other groups (p<.05) 30 minutes after bronchodilator inhalation and recovered 2 hours after bronchodilator inhalation. 5. Changes of airway deadspace was greater in the nebulizer group compared to the control group and MDI puff group 30 minutes after albuterol inhalation (p<.05) and at 2 hours (p<.01). Conclusion: Tracheal suction did not have significant effect on vital signs and pulmonary functions after OHS. Although the methods of bronchodilator inhalation did not showed any significant difference on pulmonary function, the nebulizer method increased $PaO_2$ (20%) and tidal volume transiently. If the patient needs bronchodilator inhalation with bronchospasm after OHS, the nebulizer method is the best choice. More study on the effects of bronchodilator inhalation in bronchospasm group is needed.

  • PDF

A study on evaluation of duplex loading pressure in Suction Drain Method (Suction Drain 공법에서 양방향 압력재하에 의한 효율 평가에 관한 연구)

  • Ahn, Dong-Wook;Chae, Kwang-Seok;Han, Sang-Jae;Yoon, Myung-Seok;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1256-1263
    • /
    • 2010
  • Suction Drain Method is soft ground improvement technique, in which a vacuum pressure can be directly applied to the Vertical Drain Board to promote consolidation and strengthening the soft ground. This method does not require a surcharge load, different to embankment or Preloading Method. In this study, ground improvement efficiency of suction drain method was estimated when duplex loading pressure with vacuum and pressure. During suction drain method process, surface settlement and pore pressure were monitored, and cone resistance test as well as water content were also measured after the completion of Suction Drain Method treatment.

  • PDF

Characteristics of Hardening Zone by Suction Pressure in Suction Drain Method (석션드레인 공법에서 적용 부압에 따른 Hardening Zone의 특성)

  • Han, Sang-Jae;Kim, Ki-Nyun;Kim, Soo-Sam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2C
    • /
    • pp.75-81
    • /
    • 2008
  • In this study, a series of laboratory column test on Suction Drain Method which is one of the way to make an soft ground improvement were conducted in order to investigate the effect of the Hardening Zones and the ratio of improvements depending on periods of the improvements and various applied suction pressures. On this occasion, the experimental conditions are followings; in the case of the periods of effectiveness, 4 days, 8 days, 12 days, 16 days, 20 days and in the case of the applied pressures of the Suction are -20 kPa, -40 kPa, -60 kPa and -80 kPa were carried out. As a result of test, settlement increased with suction pressure and duration increase, and gradually converged. Also, as comparing permeability decrease ratio with which calculated back from water content and numerically predicted using Hansbo's radial consolidation theory, measured value was almost coincide with predicted value when permeability decrease ratio was assumed as 2~3. Furthermore, the hardening zone was appeared within 7~8 cm of whole radial (25 cm).