• 제목/요약/키워드: Subway wall

검색결과 53건 처리시간 0.024초

전철 고상홈 승강장안전시스템 개발시험 (A Study of Safety System for High Platform)

  • 김명룡;권성태;박우현;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.416-421
    • /
    • 2001
  • The subway station platform is designed in high platform for quick getting in/out which is against ordinary train platform. Out of 370 Metropolitan subway station platforms, subway stations which have cured platform are about 38%. In these cases, as the distance between subway and platform would become longer, handicapped people's wheelchairs, baby carriers and old and feeble people can feel uncomfortable when they are getting in and out Also, passengers often fall into track because of the height difference between high platform and track. And if passengers go down on track to pick up something fallen, they sometime fail to climb up and happen to hit against subway. To solve out these kind of inconveniences and prevent accidents, we have developed subway station high platform safety system and finished tests. This safety system is consisted of safety block, screened door and safety wall. This study explained the composition and function of this system and presented the test result to identify its performance.

  • PDF

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

5678 서울도시철도 지하역사의 라돈 관리 현황 (Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway)

  • 김준현;윤현식;서강진;우희영;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

터널통과 전동차 내외부 소음 특성 규명 (Identification of Noise Characteristics for Subway Train Passing through the Underground Tunnel)

  • 조준호;이규진;정우성;홍철기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.340-345
    • /
    • 2002
  • Passengers in automobile or train are exposed to a worse noise environment when they are in the tunnel than in the open field. This is due to a relatively higher space density of sound energy by multiple reflection phenomenon of noise generated by operation of transportation vehicles from tunnel wall compared to open field. In this study, noise characteristics of subway train running through a tunnel were investigated at straight/curved track and tunnel type(semi circular/box). Also the noise measured simultaneously at inner and outer sides of train running through a tunnel, so that the coherence of the various noise sources of subway train to inner noise was evaluated.

  • PDF

흡음판이 내장된 헬름홀츠 공명기의 흡음특성 (Acoustic Characteristics of a Helmholtz Resonator with Built-In Sound Absorption Panel)

  • 양윤상;백두산;이동훈;박춘근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2014
  • Many of research on noise reduction techniques have been progressed for the improvement of noise environment in subway train. There are many way to noise reduction techniques in the tunnel, but it has been reported as an alternative to attach sound absorption material on tunnel wall. For this reason sound absorption material has been studied for application of tunnel. The objective of this study is to investigate design parameters on a Helmholtz resonator with built-in sound absorption panel for the reduction of the tunnel noise in the subway. Sound absorption panel composed of the perforated panel with sub-millimeter holes and the airspace backed a rigid wall or between panels. The experiment is performed through the change of number of perforated panel, cross sectional area and the depth of airspace of the sound absorption panel under the normal incidence sound.

  • PDF

A multivariate adaptive regression splines model for estimation of maximum wall deflections induced by braced excavation

  • Xiang, Yuzhou;Goh, Anthony Teck Chee;Zhang, Wengang;Zhang, Runhong
    • Geomechanics and Engineering
    • /
    • 제14권4호
    • /
    • pp.315-324
    • /
    • 2018
  • With rapid economic growth, numerous deep excavation projects for high-rise buildings and subway transportation networks have been constructed in the past two decades. Deep excavations particularly in thick deposits of soft clay may cause excessive ground movements and thus result in potential damage to adjacent buildings and supporting utilities. Extensive plane strain finite element analyses considering small strain effect have been carried out to examine the wall deflections for excavations in soft clay deposits supported by diaphragm walls and bracings. The excavation geometrical parameters, soil strength and stiffness properties, soil unit weight, the strut stiffness and wall stiffness were varied to study the wall deflection behaviour. Based on these results, a multivariate adaptive regression splines model was developed for estimating the maximum wall deflection. Parametric analyses were also performed to investigate the influence of the various design variables on wall deflections.

지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구 (A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure)

  • 송석준;유상건;박지웅;김은겸
    • 한국철도학회논문집
    • /
    • 제12권6호
    • /
    • pp.1024-1029
    • /
    • 2009
  • 콘크리트 구조물의 대형화에 따라 시공 중 수화열에 의한 온도 균열 발생 사례가 증가하고 있다. 지하철 콘크리트 BOX 구조물의 경우, 부재 두께가 1m 이상 되는 경우가 대부분이며, 특히 벽체는 외부구속에 의한 관통균열 발생으로 누수 및 조직 열화가 발생하여 내구성에 나쁜 영향을 주고 있다. 지하철은 일반적으로 도로를 따라 건설되므 로 교통체증을 줄이기 위한 공사기간 단축 시도가 종종 발생하게 된다. 본 연구에서는 공사시간 단축 방안으로서 한 지간씩 건너띠면서 콘크리트를 타설하는 시공방법을 제안하였으며, 이에 대한 온도균열제어에 미치는 영향을 검토하였다. 또한 벽체 높이, 타설온도, 대기온도 등을 현장조건에 따라 변화시켜 온도균열에 대한 민감도 분석을 실시하였다.

터널통과 전동차 내외부 소음 특성 규명 (Identification of Noise Characteristics for Subway Train Passing Through the Undergroud Tunnel)

  • Cho, Jun-Ho;Lee, Kyu-Jin;Jung, Woo-Sung;Hong, Cheol-Gee
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.338.2-338
    • /
    • 2002
  • Passengers in automobile or train are exposed to a worse noise environment when they are in the tunnel than in the open field. This is due to a relatively higher space density of sound energy by multiple reflection phenomenon of noise generated by operation of transportaton vehicles from tunnel wall compared to open field. In this study, noise characteristics of subway train running through a tunnel were investigated at straight/cruved track and tunnel type(semi circula/box). (omitted)

  • PDF

강널말뚝을 이용한 국내.외 시공 사례 (A Case study of steel sheet pile)

  • 여병철;김광일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.111-118
    • /
    • 1994
  • The use of steel sheet pile walls as barrier walls have the temporary for coffer dam, retaining wall in excavation, etc., but also permanent of semi-permanent for harbor construction, containment systems, vertical barrier systems for waste disposal (landfill) or subway in excavarion. In all these applicaions the resistance of the structure to seepage plays an important role. Also the stability and longevity of the construction, the possibility of permanent control and survey make the steel sheet pile wall a nearly perfect vertical barrier from a technical and economical point of view.

  • PDF