• Title/Summary/Keyword: Subway Passenger

Search Result 174, Processing Time 0.026 seconds

Investigation of Wireless Communication Technology for the WSN of Subway Station (도시철도 역사 WSN 구현을 위한 무선통신 기술 분석)

  • Kim, Gab-Young;Jeon, Bo-Ik;Ahn, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1344-1353
    • /
    • 2008
  • The trend is that the wireless communication system, which has specific characteristics ; low cost & limitation for installation, has been developed more actively than the wire communication system. Therefore, the communication system has been changed from the wire system with an optical cable to the wireless system in the various field of life. In the railroad field, lots of researches on the wireless communication system for the safety of infrastructure and the convenience of passenger have been conducted. The WSN(Wireless Sensor Network), which means same concept with USN(Ubiquitous Sensor Network), pursues the ubiquitous environment which means user can access network at anywhere and anytime. In this paper, the wireless communication technologies which are suitable for the WSN of subway station were investigated and the best solution of WSN was suggested.

  • PDF

A Study on the Risk Assessment of the Underground Space -The Estimation of Smoke Reservoir Screen for Smoke Control in Subway Station Platform (지하공간의 위험성평가에 관한 연구 -지하철 역사내의 연기제어를 위한 제연경계벽의 효용성 평가)

  • Roh Sam-Kew;Hur Jun-Ho
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.103-109
    • /
    • 2004
  • The risk of underground space become an important issue of life safety thought the Taeku subway line Accident. It is essential to study of smoke control screen to minimize the damage of human life because of smoke passage and passenger evacuation routes are on the same vertical and dispersion movement. The Fire modeling result shows the effect of fire control screen can save the evacuation time about 2-2.5 times compare to existing the system However, The designs of fire control screen need to be complied with smoke control ventilation system to present optimum design and the position of installation.

Stereoscopic Video Coding for Subway Accident Monitoring System (지하철 사고 감시를 위한 스테레오 비디오 부호화 기법)

  • Oh, Seh-Chan;Kim, Gil-Dong;Park, Sung-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.484-486
    • /
    • 2005
  • Passenger safety is a primary concern of railway system but, it has been urgent issue that dozens of people are killed every year when they falloff from train platforms. Recently, advancements in IT have enabled applying vision sensors to railway environments, such as CCTV and stereo camera sensors. In this paper, we propose a stereoscopic video coding scheme for subway accident monitoring system. The proposed scheme is designed for providing flexible video among various displays, such as control center, station employees and train driver. We uses MPEG-2 standard for coding the left-view sequence and IBMDC for predicting the P- and B-types of frames of the right-view sequence. IBMDC predicts matching block by interpolating both motion and disparity predicted macroblocks. To provide efficient stereoscopic video service. we define both temporally and spatially scalable layers for each eye's-view by using the concept of Spatio-Temporal scalability. According to the experimental results. we expect the proposed functionalities will play a key role in establishing highly flexible stereoscopic video codec for ubiquitous display environment where devices and network connections are heterogeneous.

  • PDF

Personal Management Strategies for the Financial Improvement of Seoul Metropolitan Subway Corporation (서울시지하철공사 경영혁신을 위한 인력운영 개선방안)

  • 황기연;백성준
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.172-183
    • /
    • 1998
  • The purpose of this study is to reduce the number of employees hired by Seoul Metropolitan Subway Corporation(SMSC) as a way of responding to deteriorating financial deficit problem. For the reduction, the personnel structure of Seoul Metro Rapid Transit Subway(SMRTS) newly founded in 1995 is benchmarked. Several assumptions are set for seeking the persuasive alternative; 1) no compulsory reduction of existing personnel, 2) raising the salary of SMSC to the same level of SMRTS for compensating intensified work burden, 3) hiring new employees to the amount of one-third of the reduced workforce for minimizing the problems associated with the reduction. The study suggests that the personnel reduction in relevant parts be planned in the following ways; 1) passenger transport part: from daily 3 shifts of 4 group to 2 shifts of 3 group, 2) fleet inspection, civil d: electric engineering, railtrack maintenance, signal parts: from 12 day-off to 10day-off, 3) architecture, AFC parts: from 2 shifts of 3 group to daily work, 4) fleet maintenance, architecture parts: expanding out-sourcing & automation, and 5) headquarter part: 10% reduction of the total of office workers. The study finds, by implementing the plan, that 1,270 employee can be reduced, and that aggregate 106.8 billion won will be saved for the next 10 years.

  • PDF

The Size-Oriented Particulate Mass Ratios and Their Characteristics on the Seoul Metropolitan Subway Lines

  • Lee, Eun-Sun;Lee, Tae-Jung;Park, Min-Bin;Park, Duckshin;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.217-225
    • /
    • 2016
  • The purpose of the study was to initially investigate the concentration patterns of $PM_1$, $PM_{2.5}$ and $PM_{10}$ in the Seoul subway lines, and then to figure out the PM behaviors of internal and external sources inside subway tunnels. The PMs were monitored by a light scattering real-time monitor during winter (Jan. 8-26 in 2015) and summer (July 2-Aug. 7 in 2015) in tunnel air, in passenger cabin air, and in the ambient air. The daily average $PM_{10}$, $PM_{2.5}$, and $PM_1$ concentrations on these object lines were $101.3{\pm}38.4$, $81.5{\pm}30.2$, and $59.7{\pm}19.9{\mu}g/m^3$, respectively. On an average, the PM concentration was about 1.2 times higher in winter than in summer and about 1.5 times higher in underground tunnel sections than in ground sections. In this study, we also calculated extensively the average PM mass ratios for $PM_{2.5}/PM_{10}$, $PM_1/PM_{10}$, and $PM_1/PM_{2.5}$; for example, the range of $PM_{2.5}/PM_{10}$ ratio in tunnel air was 0.82-0.86 in underground tunnel air, while that was 0.48-0.68 in outdoor ground air. The ratio was much higher in tunnel air than in outdoor air and was always higher in summer than in winter in case of outdoor air. It seemed from the results that the in/out air quality as well as a proper amount of subway ventilation must be significant influence factors in terms of fine PM management and control for the tunnel air quality improvement.

A Method to Evaluate Distance Efficiency of Seoul Metropolitan Subway by Estimating Subway Detour Factor (지하철 우회계수 산정을 통한 수도권 지하철의 거리 효율 평가 모형)

  • LEE, Jae Min;KIM, Nam Seok
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.3
    • /
    • pp.304-314
    • /
    • 2015
  • Detour of metro (subway) in metropolitan area has been regarded as one of inherent elements that make entire metro system less competitive than passenger cars. However, factors affecting detour of metro line is not specified clearly when a new subway system is planned or an existing system is improved. Previous detour-related studies was reviewed for developing 'distance efficeincy evaluation model' for metro as well as its counterpart (i.e. road). Metro line 3 (orange line) of Seoul metropolitan area was applied as a case study. As a results, the most detoured OD segment is Daechi - Apgujeong and its detour factor is 1.93 which means that the distance of the metro is 1.93 times longer distance compared to the distance of the road. The metro line 3 has averagely 20% longer distance compared to road for the identical O/D pairs.

The example of the Carbon Grounding Modules installation for PSD systems at a subway station, Seoulmetro (서울메트로 PSD장비 탄소접지모듈 설치 사례)

  • Chung, Young-Ki;Hyeon, Yong-Seop;Song, Byeong-Gwon;Kim, Yong-Hyeop
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.292-298
    • /
    • 2008
  • Seoul Metro and Seoul Metropolitan Rapid Transit Corp. have started installing screen doors at subway platforms to improve the environment of subways and prevent passengers' accidents since 2006. They are still installing screen doors at subway platforms and Metropolitan Rapid Transit Corporations in other areas are also proceeding with installment of screen doors or making preparations for it. Grounding is necessary for installing PSD systems. In case that PSD grounding is connected with existing electrical equipment grounding system, it was decided to install separate grounding for safe operation of PSD system and passenger safety. However, it's very difficult to install new grounding at the subway station compound. A way to improve this condition is that we proceed with grounding by composing grounding station by carbon grounding rod. This paper will mainly deal with how to design and construct carbon ground rod, which has been applied to PSD system grounding since 2006, including its experimental examples. In this paper, ways to secure ground resistance below 5 ohms, which is resistance necessary for PSD grounding, and to compose grounding system were also discussed. Furthermore, a ground test to check the ability to fulfill a role of PSD grounding system was conducted. As a result of applying carbon grounding module, PSD system is being operated without any problem and the installment of PSD system will be continuously expanded in the future. It's also thought that a way to integrate grounding of each functional room which has been installed at the subway station compound and to arrange equipotential grounding should be reviewed and performed promptly.

  • PDF

The Study on Fire Phenomena in The Deeply Underground Subway Station (대심도 지하역사에서의 화재현상 연구)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1773-1780
    • /
    • 2008
  • When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.

  • PDF

Subway Congestion Prediction and Recommendation System using Big Data Analysis (빅데이터 분석을 이용한 지하철 혼잡도 예측 및 추천시스템)

  • Kim, Jin-su
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.289-295
    • /
    • 2016
  • Subway is a future-oriented means of transportation that can be safely and quickly mass transport many passengers than buses and taxis. Congestion growth due to the increase of the metro users is one of the factors that hinder citizens' rights to comfortably use the subway. Accordingly, congestion prediction in the subway is one of the ways to maximize the use of passenger convenience and comfort. In this paper, we monitor the level of congestion in real time via the existing congestion on the metro using multiple regression analysis and big data processing, as well as their departure station and arrival station information More information about the transfer stations offer a personalized congestion prediction system. The accuracy of the predicted congestion shows about 81% accuracy, which is compared to the real congestion. In this paper, the proposed prediction and recommendation application will be a help to prediction of subway congestion and user convenience.

Access Delay Characteristics of Wi-Fi Network According to User Increase in Subway Section (지하철 구간에서 이용객 증가에 따른 Wi-Fi 접속 지연 특성)

  • Koh, Seoung-chon;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3455-3461
    • /
    • 2015
  • LTE and Wi-Fi networks provide wireless communication services to passengers in subway where the number of network access fluctuates according to passenger movement. While the number of network access increase, LTE can provide stable communication service but Wi-Fi suffers temporal access delay to network. This paper analyzes the increase in access delay of Wi-Fi network according to increasing user in subway section by making mathematical modeling of Wi-Fi network and simulation study. The access delay characteristics of Wi-Fi network is measured along an subway line and the results are compared to the theoretical study. These results can be applied to the connection method to build an efficient network structure between LTE and Wi-Fi interworking network and the future introduction of LTE-R.