• Title/Summary/Keyword: Substitute motion

Search Result 38, Processing Time 0.028 seconds

The Review of Functional Electrical Stimulation (기능적 전기자극에 대한 고찰)

  • Park, Kyu-Hyun;Kim, Sun-Kyoo;Chung, Hyun-Ae;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.399-405
    • /
    • 2001
  • Attainment of the goals of functional electrical stimulation(FES) applications such as strengthening of muscle, increasing muscular endurance, improvement in joint range of motion or the reduction of spasticity does not insure that patients will be able to produce voluntary muscle contraction sufficient to maintain posture or produce purposeful movements. In many patients who have sustained CNS damage, the control exerted by higher nervous system center over muscle contraction may impaired. In Searched patients, a variety of advanced therapeutic exercise techniques have been employed traditionally to facilitate the return of controlled functional muscular activity or maintain postural alignment until recovery from dysfunction occurs Among the most common clinical applications of FES for functional muscle contraction is as a substitute for static or dynamic orthotic devices

  • PDF

문형 5축 머시닝센터의 기하학적 오차해석 및 가상가공 시스템 개발

  • 윤태선;조재완;곽병만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.830-835
    • /
    • 1995
  • To quickly determine the effect of the substitute component on the machine's performance is very important in the defign and the manufacturing processes. And minimizing machine cost and maximizing machine quality mandata predictability of machine accuracy. In the study, in order to evaluate the effects of the component's geometric errors and dimensions on the machining accuracy of gantry-type 5-axis machining centers, a geometric error analysis and virtual manufacturing system is developed based on the mathematical model for the shape generation motion of machine tool considering the component's geometric errors and dimensions, the solid modeling techniques and so on.

  • PDF

A Study on the Factors Influencing the Abnormal Vibration of the Lateral Direction in Railway Vehicles Caused by Hysteresis of Critical Speed (임계속도 이력현상에 의한 철도차량 횡방향 이상 진동에 영향을 미치는 인자들에 관한 연구)

  • 정우진;심재경;조동현
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.265-275
    • /
    • 2001
  • This research has been performed to reveal the hysteresis phenomena of the hunting motion in a railway passenger cars. It is found that there are some factors and its operation region to make the nonlinear critical speed reacts to them more sensitively than the linear critical speed. The simulation results show that a self steering bogie system can be a substitute proposal to improve curving Performance together with the reduction of hysteresis of critical speed. Full scale roller rig test is carried out for the validation of the numerical results. Finally, it is certified that wear of wheel profile and stiffness discontinuities of wheelset suspension caused by deterioration have to be considered in the analysis to predict the hysteresis of critical speed precisely.

  • PDF

Vibration Analysis of Euler-Bernoulli Beam with Open Cracks on Elastic foundations Using Differential Transformation Method and Generalized Differential Quadrature Method (미분변환법과 일반화 미분구적법을 이용한 탄성 지반상의 열림 균열을 가진 Euler-Bernoulli 보의 진동 해석)

  • Hwang Ki-Sup;Yun Jong-Hak;Shin Young-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.279-286
    • /
    • 2006
  • The main purpose of this paper is to apply differential transformation method(DTM) and generalized differential quadrature method(GDQM) to vibration analysis of Euler-Bernoulli beam with open cracks on elastic foundation. In this paper the concepts of DTM and GDQM were briefly introduced. The governing equation of motion of the beam with open cracks on elastic foundation is derived. The cracks are modeled by massless substitute spring. The effects of the crack location, size and the foundation constants, on the natural frequencies of the beam, are investigated. Numerical calculations are carried out and compared with previous published results.

Development of a Geometric Error Analysis and Virtual Manufacturing System for Gantry-Type 5-Axis Machining Centers (문형 5축 머시닝센터의 기하학적 오차해석 및 가상가공 시스템 개발)

  • 윤태선;조재완;김석일;곽병만
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.172-179
    • /
    • 1998
  • To quickly determine the effect of the substitute component on the machine's performance is very important in the design and manufacturing processes. And minimizing machine cost and maximizing machine quality mandate predictability of machine accuracy. In this study, in order to evaluate the effects of the component's geometric errors and dimensions on the machining accuracy of gantry-type 5-axis machining centers, a geometric error analysis and virtual manufacturing system are developed based on the mathematical model for the shape generation motion of machine tool considering the component's geometric errors and dimensions, the solid modeling techniques and so on.

  • PDF

A Study on a Repair Technique for a Reinforced Concrete Frame Subjected to Seismic Damage Using Prestressing Cable Bracing

  • Lee, Jin Ho;EI-Ganzory, Hisham
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.53-60
    • /
    • 2001
  • The proposed building upgrading technique employs prestressing cables to function as bracing to improve the seismic performance during future events. A four-story reinforced concrete moment resisting frame damaged from an ultimate limit state earthquake is assessed and upgraded using the proposed technique. Both existing and upgraded buildings are evaluated in regard of seismic performance parameters performing static lateral load to collapse analysis and dynamic nonlinear time history analysis as well. To obtain realistic comparison of seismic performance between existing and upgraded frames, each frame is subjected to its critical ground motion that has strength demand exceeding the building strength supply. Furthermore, reliability of static lateral load to collapse analysis as a substitute to time history analysis is evaluated. The results reveal that the proposed upgrading technique improves the stiffness distribution compared to the ideal distribution that gives equal inter-story drift. As a result, the upgraded building retains more stories that contribute to energy dissipation. The overall behavior of upgraded building beyond yield is also enhanced due to the gradual change of building stiffness as the lateral load increases.

  • PDF

Performance based evaluation of RC coupled shear wall system with steel coupling beam

  • Bengar, Habib Akbarzadeh;Aski, Roja Mohammadalipour
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.337-355
    • /
    • 2016
  • Steel coupling beam in reinforced concrete (RC) coupled shear wall system is a proper substitute for deep concrete coupling beam. Previous studies have shown that RC coupled walls with steel or concrete coupling beam designed with strength-based design approach, may not guarantee a ductile behavior of a coupled shear wall system. Therefore, seismic performance evaluation of RC coupled shear wall with steel or concrete coupling beam designed based on a strength-based design approach is essential. In this paper first, buildings with 7, 14 and 21 stories containing RC coupled shear wall system with concrete and steel coupling beams were designed with strength-based design approach, then performance level of these buildings were evaluated under two spectrum; Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE). The performance level of LS and CP of all buildings were satisfied under DBE and MCE respectively. In spite of the steel coupling beam, concrete coupling beam in RC coupled shear wall acts like a fuse under strong ground motion.

Agreement of Manual Muscle Testing and Test-Retest Reliability of Hand Held Dynamometer for the Posterior Gluteus Medius Muscle for Patients With Low Back Pain (요통 환자를 대상으로 후중둔근 도수근력검사의 일치도 및 휴대용 근력계 측정 방법의 신뢰도 검사)

  • Park, Kyue-Nam;Kim, Hyun-Sook;Choi, Houng-Sik;Lee, Won-Hwee;Ha, Sung-Min;Kim, Su-Jung
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study was to assess the agreement of manual muscle testing (MMT) and test-retest reliability of a hand held dynamometer for the posterior gluteus medius muscle, with and without lumbar stabilization, using a pressure biofeedback unit for patients with low back pain. The pressure biofeedback unit was used to minimize the substitute motion of the lumbopelvic region during hip abduction in patients lying on their side. Fifteen patients with low back pain participated in this study. A tester determined the MMT grades of the posterior gluteus medius with and without the pressure biofeedback unit. Active hip abduction range of motion with an inclinometer and the strength of their posterior gluteus medius using a hand held dynamometer were measured with and without the pressure biofeedback unit in the MMT position. The agreement of the grade of muscle strength in the MMT, and intra-rater reliability of both the active hip abduction range of motion and the strength of posterior gluteus medius were analyzed using the weighted kappa and intraclass correlation coefficient (ICC), respectively. The agreement of MMT with the pressure biofeedback unit (weighted kappa=.92) was higher than the MMT (weighted kappa=.34)(p<.05). The inclinometer with pressure biofeedback unit measurement of the active hip abduction range of motion had an excellent intra-rater reliability (ICC=.90). Also, the hand held dynamometer with pressure biofeedback unit measure of strength of the posterior gluteus medius had a good intra-rater reliability (ICC=.85). Therefore, the test for muscle strength with pressure biofeedback unit will be a reliable method for the determination of the MMT grades or amount of posterior gluteus medius muscle strength and the measurement of the range of motion for hip abduction in patients with low back pain.

Reconstruction of Anterior Cruciate Ligament with Human Allograft (동종 이식건을 이용한 전방 십자 인대 재건술)

  • Suh Jeung-Tak;Cheon Sang-Jin;Lee Jung-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • Purpose : The purpose of this study is to evaluate the clinical outcomes and radiological changes after reconstruction of anterior cruciate ligament with human allograft. Material and Method : Authors analyzed 22 cases of anterior cruciate ligament allograft reconstruction which were done from January, 1995 to December, 1998 and could be followed up for a year or more. All cases were followed and reviewed in terms of anterior drawer test, Lachman test, Pivot shift test, radiographic examination, knee range of motion, and side-to-side difference of anteroior tibial translation using CA-4000 knee motion analyzer, and Lysholm knee scoring system. Result : The mean Lysholm knee score was 54 preoperatively and improved to 81 postoperatively by average of 27. The side-to-side difference of anterior tibial translation using CA-4000 knee motion analyser was less than 3 mm in 16 cases$(73\%)$, between 3 and 5 mm in 4 cases$(18\%)$, and greater than 6 min in 2 cases$(9\%)$. Average tibial tunnel enlargement was 1.5 mm, but there were not any osteoiysis or cystic formation along the tunnel and no relationship between tunnel enlargement and clinical outcome. Conclusion : Although this study had limited cases, clinical results of anterior cruciate allograft reconstruction were similar to those of reconstruction with autograft reported in the literatures. We think that allograft is an acceptable substitute fer autograft in anterior cruciate ligament reconstruction.

  • PDF

Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity

  • Block, Kai Tobias;Chandarana, Hersh;Milla, Sarah;Bruno, Mary;Mulholland, Tom;Fatterpekar, Girish;Hagiwara, Mari;Grimm, Robert;Geppert, Christian;Kiefer, Berthold;Sodickson, Daniel K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.87-106
    • /
    • 2014
  • Purpose : To describe how a robust implementation of a radial 3D gradient-echo sequence with stack-of-stars sampling can be achieved, to review the imaging properties of radial acquisitions, and to share the experience from more than 5000 clinical patient scans. Materials and Methods: A radial stack-of-stars sequence was implemented and installed on 9 clinical MR systems operating at 1.5 and 3 Tesla. Protocols were designed for various applications in which motion artifacts frequently pose a problem with conventional Cartesian techniques. Radial scans were added to routine examinations without selection of specific patient cohorts. Results: Radial acquisitions show significantly lower sensitivity to motion and allow examinations during free breathing. Elimination of breath-holding reduces failure rates for non-compliant patients and enables imaging at higher resolution. Residual artifacts appear as streaks, which are easy to identify and rarely obscure diagnostic information. The improved robustness comes at the expense of longer scan durations, the requirement for fat suppression, and the nonexistence of a time-to-center value. Care needs to be taken during the configuration of receive coils. Conclusion: Routine clinical use of radial stack-of-stars sequences is feasible with current MR systems and may serve as substitute for conventional fat-suppressed T1-weighted protocols in applications where motion is likely to degrade the image quality.