Agreement of Manual Muscle Testing and Test-Retest Reliability of Hand Held Dynamometer for the Posterior Gluteus Medius Muscle for Patients With Low Back Pain  

Park, Kyue-Nam (Dept. of Rehabilitation Therapy, The Graduate School, Yonsei University)
Kim, Hyun-Sook (Dept. of Physical therapy, Yeojoo Institute of Technology)
Choi, Houng-Sik (Dept. of Physical therapy, Hanseo University)
Lee, Won-Hwee (Dept. of Rehabilitation Therapy, The Graduate School, Yonsei University)
Ha, Sung-Min (Dept. of Rehabilitation Therapy, The Graduate School, Yonsei University)
Kim, Su-Jung (Dept. of Rehabilitation Therapy, The Graduate School, Yonsei University)
Publication Information
Physical Therapy Korea / v.18, no.3, 2011 , pp. 67-75 More about this Journal
Abstract
The purpose of this study was to assess the agreement of manual muscle testing (MMT) and test-retest reliability of a hand held dynamometer for the posterior gluteus medius muscle, with and without lumbar stabilization, using a pressure biofeedback unit for patients with low back pain. The pressure biofeedback unit was used to minimize the substitute motion of the lumbopelvic region during hip abduction in patients lying on their side. Fifteen patients with low back pain participated in this study. A tester determined the MMT grades of the posterior gluteus medius with and without the pressure biofeedback unit. Active hip abduction range of motion with an inclinometer and the strength of their posterior gluteus medius using a hand held dynamometer were measured with and without the pressure biofeedback unit in the MMT position. The agreement of the grade of muscle strength in the MMT, and intra-rater reliability of both the active hip abduction range of motion and the strength of posterior gluteus medius were analyzed using the weighted kappa and intraclass correlation coefficient (ICC), respectively. The agreement of MMT with the pressure biofeedback unit (weighted kappa=.92) was higher than the MMT (weighted kappa=.34)(p<.05). The inclinometer with pressure biofeedback unit measurement of the active hip abduction range of motion had an excellent intra-rater reliability (ICC=.90). Also, the hand held dynamometer with pressure biofeedback unit measure of strength of the posterior gluteus medius had a good intra-rater reliability (ICC=.85). Therefore, the test for muscle strength with pressure biofeedback unit will be a reliable method for the determination of the MMT grades or amount of posterior gluteus medius muscle strength and the measurement of the range of motion for hip abduction in patients with low back pain.
Keywords
Agreement; Low back pain; Manual muscle testing; Posterior gluteus medius; Pressure biofeedback unit; Reliability;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Arab AM, Nourbakhsh MR. The relationship between hip abductor muscle strength and iliotibial band tightness in individuals with low back pain. Chiropr Osteopat. 2010;18:1.   DOI
2 Blackman NJ, Koval JJ. Interval estimation for Cohen's kappa as a measure of agreement Stat Med. 2000;19:723-741.   DOI   ScienceOn
3 Chaitow L, Muscle Energy Techniques. London, Churchill Livingstone, 1996.
4 Click Fenter P, Bellew JW, Pitts TA, et al. Reliability of stabilised commercial dynamometers for measuring hip abduction strength: A pilot study. Br J Sports Med. 2003;37(4):331-334.   DOI   ScienceOn
5 Cuthbert SC, Goodheart GJ Jr. On the reliability and validity of manual muscle testing: A literature review. Chiropr Osteopat. 2007;15:4.   DOI
6 Cynn HS, Oh JS, Kwon OY, et al. Effects of lumbar stabilization using a pressure biofeedback unit on muscle activity and lateral pelvic tilt during hip abduction in sidelying. Arch Pbys Med Rehabil. 2006;87(11):1454-1458.   DOI   ScienceOn
7 Devita P, Hunter PB, Skelly WA. Effects of a functional knee brace on the biomechanics of running. Med Sci Sports Exerc. 1992;24:797-806.
8 Dunn JC, Maura D. Interater reliability of knee muscle forces obtained by hand-held dynamometer from elderly subjects with degenerative back pain. J Geriatr Phys Ther. 2003;26(3):23-29.   DOI   ScienceOn
9 Escolar DM, Henricson EK, Mayhew J, et al. Clinical evaluator reliability for quantitative and manual muscle testing measures of strength in children. Muscle Nerve. 2001;24(6):787-793.   DOI   ScienceOn
10 Fredericson M, Cookingham CL, Chaudhari AM, et al. Hip abductnr weakness in distance runners with iliotibial band syndrome. Clin J Sport Med. 2000;10(3) :169-175.   DOI   ScienceOn
11 Frese E, Brown M, Norton BJ. Clinical reliability of manual muscle testing. Middle trapezius and gluteus medius muscles. Phys Ther. 1987;67(7):1072-1076.   DOI
12 Hossain M, Nokes LD. A model of dynamic sacro-iliac joint instability from malrecruitment of gluteus maximus and biceps femoris muscles resulting in low back pain. Med Hypotheses. 2005;65(2):278-281.   DOI   ScienceOn
13 Hsieh CY, Phillips RB. Reliability of manual muscle testing with a computerized dynamometer. J Manipulative Physiol Ther. 1990;13(2):72-82.
14 Hungerford B, Gilleard W, Hodges P. Evidence of altered lumbopelvic muscle recruitment in the presence of sacroiliac joint pain. Spine (Phila Pa 1976). 2003;28(14):1593-1600.
15 Inman VT. Functional aspects of the abductor muscles of the hip. J Bone Joint Surg Am. 1947;29(3):607-619.
16 Kankaanpaa M, Taimela S, Laaksooen D, et al. Back and hip extensor fatigability in chronic low back pain patients and controls. Arch Phys Med Rebabil. 1998;79(4):412-417.   DOI   ScienceOn
17 Kendall FP, Provance PG, McCreary EK. Muscles: Testing and function with posture and pain. 4th ed. Baltimore, Williams & Wilkins, 2005.
18 Li RC, Jasiewicz JM, Middletoo J, et al. The development, validity, and reliability of a manual muscle testing device with integrated limb position sensors. Arch Phys Med Rebabil. 2006;87(3):411-417.   DOI   ScienceOn
19 Lu TW, Hsu HC, Chang LY, et al. Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: Comparison of a new device with band-held dynamometry. J Rebabil Med. 2007;39(9):679-684.
20 Maluf KS, Sahrmann SA, Van Dillen LR. Use of a classification system to guide nonsurgical management of a patient with chronic low back pain. Phys Ther. 2000;80(11):1097-1111.
21 Phil Page, Clare Frank, Robert Lardner. Assessment and Treatment of Muscle Imbalance: The Janda approach. Champaign, Human Kinetics, 2010.
22 Nadler SF, Malanga GA, Feinberg JH, et al. Relationship between hip muscle imbalance and occurrence of low back pain in collegiate athletes: A prospective study. Am J Phys Med Rehabil. 2001;80(8):572-577.   DOI   ScienceOn
23 Neumann DA. Kinesiology of the Musculoskeletal System: Foundations for physical rehabilitation. St. Louis, Mosby, 2002.
24 Perry J, Weiss WB, Burnfield JM, et al. The supine hip extensor manual muscle test: A reliability and validity study. Arch Phys Med Rebabil. 2004;85(8):1345-1350.   DOI   ScienceOn
25 Pollard H, Lakay B, Tucker F, et al. Interexaminer reliability of the deltoid and psoas muscle test. J Manipulative Physiol Ther. 2005;28(1):52-56.   DOI   ScienceOn
26 Pua YH, Wrigley TV, Cowan SM, et al. Intrarater test-retest reliability of hip range of motion and hip muscle strength measurements in persons with hip osteoarthritis. Arch Phys Med Rebabil. 2008;89(6):1146-1154.   DOI   ScienceOn
27 Sahrmann S. Diagnosis and Treatment of Movement Impairment Syndrome. St Louis, Mosby, 2002.
28 Schmitt WH Jr, Cuthbert SC. Common errors and clinical guidelines for manual muscle testing: the "arm test" and other inaccurate procedures. Chiropr Osteopat. 2008;16:16.   DOI
29 Wadsworth CT, Krishnan R, Sear M, et al. Intrarater reliability of manual muscle testing and band-held dynametric muscle testing. Phys Ther. 1987;67(9):1342-1347.   DOI