• 제목/요약/키워드: Subcutaneous Temperature

검색결과 48건 처리시간 0.029초

Microwave Radiometry 원리를 이용한 생체 내부 온도 추정 (Subcutaneous Temperature Estimation By Microwave Radiometry)

  • 김경섭;이정환
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.357-364
    • /
    • 2006
  • Microwave Radiometry is the spectral measurement of eleclromagnetic radiation at frequency bands in the microwave region. One particular application of Microwave Radiometry is for analyzing temperature difffrentials of inside of human body to detect and diagnose pathologic conditions in which the temperature differentials are related with the symptoms of certain diseases. To accomplish this aim, we propose a new calibration method for estimating subcutaneous temperature by Microwave Radiometer and we also suggest a tumor-imitator phantom structure for simulating heat diffusion propagated by tissues around tumors to evaluate the discernment of brighuless temperature difffrentials.

초음파 적용시 전파매질에 따른 표면열과 심부열의 변화 (The Change of Superficial and Deep Heats in Ultrasound Application by Coupling Media)

  • 이영희;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.57-67
    • /
    • 2000
  • The purpose of this study was carried out in five rabbits of 3kg to investigate the change of superficial and deep heats in ultrasound application by coupling media. Temperature measured with thermistor needle at skin. subcutaneous, muscle in before coupling media application, after coupling media application. 2minutes. 5minutes, 7minutes, 10minutes. Coupling media was used gel, glycerin, distilled water. The data was analyzed using spss/pc+and t-test The results were as fallow : 1. With skin. gel was significant temperature change in 2minutes(p<.05). glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 7minutes(p<.01), 10minutes(p<.01). distilled water was significant temperature change in post coupling media(p<.05), 2minutes(p<.01). 5minutes(p<.05). 7minutes(p<.01). 10minutes(p<.01). With subcutaneous. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 10minutes(p<.01). distilled water was no temperature change. With muscle. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05). 5minutes(p<.05). 7minutes(p<.05). 10minutes( p<.05). distilled water was significant temperature change in 10minutes(p<.05). 2. Superficial heats of skin and subcutaneous was higher temperature change than Deep heats of muscle. 3. Gel. glycerin. distilled Water required minimum treatment 10minutes fur thermal effect. 4. Gel was low temperature change superficial and deep heats. and glycerin was high temperature change superficial and deep heats. This results show that gel is high transmissiveness in the coupling media and glycerin is low transmissiveness in the coupling media.

  • PDF

Correlation between Abdominal Fat Distribution and Abdominal Temperature in Korean Premenopausal Obese Women

  • Song, Eun-Mo;Kim, Eun-Joo;Kim, Koh-Woon;Cho, Jae-Heung;Song, Mi-Yeon
    • 대한한의학회지
    • /
    • 제34권2호
    • /
    • pp.1-9
    • /
    • 2013
  • Objectives: Considering that homeothermy is a major component of metabolic rate, body temperature might play a role in the pathophysiology of obesity. This study aimed to determine the relationship between abdominal fat distribution and abdominal temperature in Korean, premenopausal, obese women. Methods: Weight and height were measured in 26 premenopausal, obese women to calculate body mass index (BMI). Obesity was defined as a $BMI{\geq}25kg/m^2$. Waist circumference (WC) was also measured as well as abdominal fat by computed tomography (CT) and abdominal temperature by digital infrared thermographic imaging (DITI). Results: Visceral abdominal fat area was found to have a significant negative correlation with the temperature of Guanyuan (CV4, lower abdomen acupoint). We also found the visceral-subcutaneous fat ratio had a significant negative correlation with the temperature of CV4 and Right Tianshu (RST25, lateral navel acupoint). Only visceral fat and its ratio to subcutaneous fat had a significant correlation with abdominal temperature. Subcutaneous fat area and total fat area were not correlated with abdominal temperature. Conclusions: This study suggests that abdominal visceral fat has a significant negative correlation with abdominal temperature. Further study is needed to uncover the relationship between abdominal fat distribution and temperature regulation in obese individuals and to define the role of body temperature in the pathogenesis of obesity.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

향한기의 표의훈련이 피하지방두께에 미치는 영향 (Effect on the Subcutaneous Fat Thickness of the clothing Training in the Cold Condition)

  • 박승순;이원자
    • 한국의류학회지
    • /
    • 제23권4호
    • /
    • pp.551-562
    • /
    • 1999
  • This study was intended to investigate the effect on the human body such as subcutaneous fat thickness the circumference of extremities etc. of the clothing training of putting on thin clothes periodically from the cold period. The subjects were divided into the clothing training group and the non-training group, The training group was asked to wear cool clothes in daily life and to wear the training clothes of T-shirts with half-length sleeves and pants and perform the clothing training for two hours daily three times a week in a cold environment over the period from November to February. The non-training group was asked to lead a life wearing comfortable clothes. Then a comparative experiment was conducted at 15$\pm$1$^{\circ}C$, 50$\pm$5% R, H and 0.25m/sec before and after the clothing training. After the clothing training regardless of gender subcutaneous fat thickness was more increased and total clothing weight per the surface area of the body was decreased in the training group than the non-training group. The training group showed lower skin temperature in the limbs and lower average skin temperature than the non-training group irrespective of gender which proved the effect of the clothing training. The training group was shown to have attendancy toward a greater sense of warmth and a less sense of discomfort which proved the effect of the clothing training.

  • PDF

전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고 (A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture)

  • 윤지원;이현;김윤주;강재희
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

피하에 효과적인 열 자극을 위한 고주파 자극 프로토콜 개발 (Development of RF Stimulating Protocol for Effective Heat-Stimulus in Subcutaneous Tissue)

  • 명현석;이대원;김한성;이경중
    • 전자공학회논문지
    • /
    • 제49권10호
    • /
    • pp.194-201
    • /
    • 2012
  • 뜸은 질병에 대한 면역력을 높이고 질병을 치유하는데 효과적인 반면 뜸의 열 자극 세기를 조절하기 힘들어 피부에 고통을 유발시키며 화상을 입히는 부작용이 발생된다. 이런 한계점을 극복하기 위해 자극 조절이 가능한 고주파 열 자극 시스템을 개발하였으며, 동물에게 뜸질을 할 경우 얻어지는 온도분포와 유사한 자극 프로토콜을 개발하였다. 자극을 위한 시스템은 2MHz, 200W의 고주파유전가열장치, 절연프로브, 절연플레이트, 음압 발생부 및 온도측정부로 구성되어있다. 자극 프로토콜 설계를 위해서 일차적으로 토끼의 대퇴부에 뜸질시 표피, 피하 5mm와 피하10mm에서 온도분포를 획득하였다. 획득된 뜸질의 온도분포와 유사한 온도분포로 자극하기 위해서 자극펄스의 duty ratio와 반복회수 및 출력을 제어하였다. 뜸질과 고주파 자극시 피하의 온도분포를 비교해본 결과 피하 5mm와 10mm 부위에서의 상관관계는 각각 95%와 91%로 일치함을 보여주었다. 또한, 고주파 자극시 표피에서의 온도분포는 뜸에 비해 현저하게 낮게 나옴을 확인하였다. 이를 통해 고주파 열 자극 시스템은 뜸질의 문제점인 화농, 물집과 같은 부작용을 유발시키지 않으면서 피하에 뜸질과 유사한 열 자극이 가능함을 보여주었다.

탄성 압박 밴드를 이용한 인체 부위별 의복압 가압 수준에 관한 연구 (Determination of the Garment Pressure Level Using the Elastic Bands by Human Body Parts)

  • 백윤정;최정화
    • 한국의류학회지
    • /
    • 제32권10호
    • /
    • pp.1651-1658
    • /
    • 2008
  • This study was to decided the proper garment pressure level on the human body parts. Six volunteers (female: 30-40years) put on the same types of bands, a brief, and a non-woven gown. Garment pressure was measured in regular order with the elastic band on the human body parts such as the upper arm, the waist, the thigh, and the calf. At the same time, physiological responses such as the skin blood flow rate on 2 fingers, 7 different skin temperatures, rectal temperature, heat rates, and subjective responses about the pressure sensation, thermal sensation, and humidity sensation were measured and inquired. The results were as follows; 1. The thicker subcutaneous fat thickness, the higher the mean garment pressure on pressurizing the upper arm(p<.001). Also the thicker subcutaneous fat thickness. the thicker the upper arm circumference. 2. Heart rates increased pressured the upper arm and decreased pressured the waist, the thigh, and the calf. The higher the garment pressure, the higher heart rates on all body parts were pressured. Especially lean subjects showed higher physiological load than others. 3. On pressurizing the upper arm, heart rates, rectal temperature, and mean skin temperature were higher than without pressured state and pressured other body parts.4. The proper garment pressure levels were decided 30gf/$cm^2$ for fat people, 20gf/$cm^2$ for others on the upper arms and 24gf/$cm^2$ on the calf.

Preparation and Biodegradation of Thermosensitive Chitosan Hydrogel as a Function of pH and Temperature

  • Han, Hee-Dong;Nam, Da-Eun;Seo, Dong-Hoan;Kim, Tae-Woo;Shin, Byung-Cheol;Choi, Ho-Suk
    • Macromolecular Research
    • /
    • 제12권5호
    • /
    • pp.507-511
    • /
    • 2004
  • We have developed an injectable thermosensitive hydrogel for local drug delivery to treat cancers clinically. We selected chitosan as a polymer matrix because of its biocompatibility and biodegradability. Glycerol 2-phosphate disodium salt hydrate (${\beta}$-GP) was used to neutralize the chitosan solution to physiological pH. The chitosan solution displayed a sol-gel phase transition in a pH-and temperature-dependent manner and formed an endothermic hydrogel after subcutaneous injection into mouse in the presence of ${\beta}$-GP. Additionally, we evaluated the biodegradation of chitosan hydrogel in mice by measuring the volume of injected chitosan hydrogel after subcutaneous injection. The injected chitosan hydrogel in mice was sected and stained with hematoxylin-eosin reagent for histological observation to confirm biodegradation of the hydrogel by the infiltrated cells. Chitosan hydrogel systems that possess biocompatibility and biodegradability could be promising thermosensitive injectable materials useful as depot systems for local anti-cancer drug delivery.

Detection of Fever with Subcutaneously Implanted Thermo-Loggers in Cattle Administered with Lipopolysaccharide

  • Ro, Younghye;Bok, Jin-Duck;Lee, Hun-Jun;Kang, Sang-Kee;Kim, Danil;Lee, Yoonseok
    • 한국임상수의학회지
    • /
    • 제35권3호
    • /
    • pp.97-99
    • /
    • 2018
  • The aim of this study is to determine whether subcutaneous temperature (ST) was correlated with rectal temperature (RT) in cattle with inducing artificial fever. In order to determine the correlation between their temperatures, the experiment was performed as follow: Among nine Holstein steers, lipopolysaccharide (LPS) was intravenously administered at a dose of $0.5{\mu}g/kg$ of body weight to six Holstein steer, then, 6 ml of saline was administrated to three steers as a control group. After LPS injection, ST was recorded using subcutaneously implanted thermo-logger sensors at 10-min intervals, and RT was measured using a digital thermometer at 0, 1, 2, 3, 4, 8 and 12 h. In steers with LPS injection, RT was highest at 3 to 4 h and recovered to a pre-challenge temperature at 8-22 h. A similar fluctuation was shown in ST except for an unexpected decrease at 1 h, and a positive correlation between RT and ST was observed in LPS-challenged steers (r = 0.497, P = 0.04). This result suggests that ST could be utilized as an index for early detection of infectious diseases or physiological events.