Determination of the Garment Pressure Level Using the Elastic Bands by Human Body Parts  

Baek, Yoon-Jeong (National Institute of Agricultural Science and Technology, Rural Development Administration)
Choi, Jeong-Wha (Dept. of Clothing & Textiles, Seoul national University/Research Institute of Human Ecology, Seoul National University)
Publication Information
Journal of the Korean Society of Clothing and Textiles / v.32, no.10, 2008 , pp. 1651-1658 More about this Journal
Abstract
This study was to decided the proper garment pressure level on the human body parts. Six volunteers (female: 30-40years) put on the same types of bands, a brief, and a non-woven gown. Garment pressure was measured in regular order with the elastic band on the human body parts such as the upper arm, the waist, the thigh, and the calf. At the same time, physiological responses such as the skin blood flow rate on 2 fingers, 7 different skin temperatures, rectal temperature, heat rates, and subjective responses about the pressure sensation, thermal sensation, and humidity sensation were measured and inquired. The results were as follows; 1. The thicker subcutaneous fat thickness, the higher the mean garment pressure on pressurizing the upper arm(p<.001). Also the thicker subcutaneous fat thickness. the thicker the upper arm circumference. 2. Heart rates increased pressured the upper arm and decreased pressured the waist, the thigh, and the calf. The higher the garment pressure, the higher heart rates on all body parts were pressured. Especially lean subjects showed higher physiological load than others. 3. On pressurizing the upper arm, heart rates, rectal temperature, and mean skin temperature were higher than without pressured state and pressured other body parts.4. The proper garment pressure levels were decided 30gf/$cm^2$ for fat people, 20gf/$cm^2$ for others on the upper arms and 24gf/$cm^2$ on the calf.
Keywords
Garment pressure; Skin blood flow rate; Heart rates; Subcutaneous fat thickness;
Citations & Related Records
연도 인용수 순위
  • Reference
1 이상숙. (1973). 건강한 생활습관: 현대생활 의학전서(I). 서울: 선문출판사
2 조정미. (1986). 신체 동작과 의복 여유분에 따른 의복압에 대한 탐색적 연구. 연세대학교 대학원 석사학위 논문
3 최광배. (1989). 한국인의 피부 혈류량에 대한 연구. 중앙대학교 대학원 박사학위 논문
4 Dirik, E., Aydin, A., Kuruk, S., & Sahin, B. (2001). Limb girdle muscular dystrophy type 2A presenting with cardiac arrest. Pediatric Neurology, 24(3), 235−237   DOI   ScienceOn
5 Giel, P., Liddiard, K., Currie, K., & Wood, M. (1997). Direct measurement of cutaneous pressures generated by pressure garment. Burns, 23(2), 137−141   DOI   ScienceOn
6 Hafner, J., Luthi, W., Hanssle, H., Kammerlander, G., & Bueg, G. (2000). Instruction of compression therapy by means of interface pressure measurement. Dematol. Surg., 26, 481−487   DOI   ScienceOn
7 Ng, F. & Hui, P. (1999). Effect of hem edges on the interface pressure of pressure garments. Int. J. Cloth. Sci. & Techno., 11(5), 251−261   DOI   ScienceOn
8 Watanuki, S. (1994). Improvements on a design of girdle by using cardiac output mjkand pressure sensation. Ann. Physiol. Anthropol., 13(4), 157−165   DOI   ScienceOn
9 백윤정, 최정화. (2003). 의복압 측정 장치, 대한민국 특허등록번호 05093685. 서울: 특허청
10 백윤정, 최정화. (2007). 거들과 올인원에 있어서 의복압 측정 부위 선정에 관한 연구. 한국지역사회생활과학회지, 18(4), 609−616
11 안영숙. (1986). 화운데이션 착용 실태에 관한 조사 연구. 이화여자대학교 대학원 석사학위 논문
12 강승완, 이은일, 염용태, 김해준. (1996). 국소진동장해 평가를 위한 감각신경 및 말초 혈류량 검사에 관한 연구. 대한산업의학회지, 8(2), 210−222
13 박영득, 김효은. (1990). 거들 착용이 신체 내 기능에 미치는 영향에 관한 연구. 대한가정학회지, 28(1), 1−7
14 황정욱, 박대환. (1996). Laser Doppler Flowmetry를 이용한 각 인체 부위별 피부 혈류량 측정. 대한성형외과학회지, 23(2), 394−404
15 Chamot, S. R., Movaffaghy, A. M., Petri, B. L., & Riva, C. E. (1999) Blood flow in the human iris measured by laser Doppler flowmetry. Microvascular Research, 57, 153−161   DOI   ScienceOn
16 나동균, 신극선, 유재덕, 김덕원. (1992). Impedance plethysmography를 이용한 수지 혈류량의 측정. 대한성형외과학회지, 19(4), 602−608
17 원기정, 박병일, 김용배, 양순재, 박종섭. (1993). 수부의 부위별 혈류량 측정에 관한 연구. 대한성형외과학회지, 20(5), 969−974
18 이준옥, 남윤자. (1999). 중년 여성의 인체 만족도와 화운데이션 착용 태도에 관한 연구. 복식, 43, 83−95   과학기술학회마을
19 Watanuki, S. & Murata, H. (1994). Effects of wearing compression stockings on cardiovascular responses. Ann. Physiol. Anthropol., 13(3), 121−127   DOI   ScienceOn
20 Shelton, F., Barnett, R., & Meyer, E. (1998). Full-body interface pressure testing as a method for performance evaluation of clinical support surfaces. Appl. Ergonomics, 29(6), 491−497   DOI   ScienceOn
21 Kraemer, J., Volek, S., Bush, A., Gotshalk, A., Wagner, R., Gomez, L., Zatsiorsky, M., Duzrte, M., Ratamess, A., Mazzetti, A., & Selle, J. (2000). Influence of compression hosiery on physiological responses to standing fatigue in women. Med. Sci. Sports & Exer., 32(11), 1849−1858   DOI   ScienceOn
22 이준옥. (2001). 개인별 맞춤 거들 제작을 위한 기초 연구: 비만 여성을 중심으로. 서울대학교 대학원 박사학위 논문
23 백윤정, 최정화, 이경숙. (2007). 브래지어와 허리거들에 있어서 의복압 측정 부위 선정에 관한 연구. 한국지역사회생활과학회지, 18(3), 445−454
24 박영득. (1991). 브래지어 착용 조건에 따른 인체의 형태적, 생리적 변화에 관한 실험적 연구. 대한가정학회지, 29(1), 27−35
25 Mori, Y., Kioka, E., & Tokura, H. (2002). Effects of pressure on the skin exerted by clothing responses of urinary catecholamines and cortisol, heart rates and nocturnal urinary melatonin in humans. Int. J. Biomet., 47(1), 1−5   DOI
26 이순원, 조성교, 최정화. (1997). 의복과 환경. 서울: 방송통신대학교출판부
27 Tazelaar, J., Neumann, M., & Roos, P. (1999). Long cotton wool rolls as compression enhancers in macrosclerotherapy for varicose veins. Dematol. Surg., 25, 38−40   DOI   ScienceOn