• Title/Summary/Keyword: Sub-ROI

Search Result 31, Processing Time 0.029 seconds

핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰 (A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging)

  • 김지현;이주영;박훈희
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

블록 명암대비와 프로젝션에 기반한 2차원 바코드 검출 알고리즘 (A 2-Dimensional Barcode Detection Algorithm based on Block Contrast and Projection)

  • 최영규
    • 정보처리학회논문지B
    • /
    • 제15B권4호
    • /
    • pp.259-268
    • /
    • 2008
  • 일차원 심벌의 데이터 용량 문제를 극복하기 위하여 십 여년 전에 2차원 바코드가 처음으로 소개되었다. 본 논문에서는 그레이 영상에서부터 2차원 바코드 영역을 검출하기 위한 알고리즘을 제안하는데, 특히 손에 들고 사용하는 2D 바코드 인식 시스템에 탑재를 목표로 한다. 제안된 방법에서는 먼저 영상 내 2차원 바코드의 대략적인 위치를 검출하기 위해 블록 명암대비를 바탕으로 한 후보블록 기준을 정의하고, 관심영역으로부터 바코드 영역을 정확히 분리하기 위해 그레이 스케일 프로젝션과 부 화소 처리를 사용한다. 마지막으로 분리된 바코드 영역은 이어지는 디코딩 단계를 위해 역 투시변환을 통해 정규화 된다. 본 논문에서는 QR-코드에 대한 디코딩을 위한 후처리 과정도 소개한다. 제안된 방법은 다양한 조명상태나 인쇄상태 및 투시변환에 의해 영상에 강한 왜곡이 있는 경우에도 좋은 성능을 나타낸다. 실험을 통해 제안된 방법이실시간으로 다양한 종류의 2차원 바코드에 대한 코드영역을 안정적이고 효과적으로 추출해 주는 것을 알 수 있었다.

FHD급 DIC 플랫폼의 변위계측용 영상품질 분석 (Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement)

  • 박종배;강민구
    • 인터넷정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.105-111
    • /
    • 2018
  • 건축 구조물의 상대적인 변위 계측을 위하여 2메가 픽셀 Full HD(FHD) 해상도의 카메라와 디지털 영상상관(DIC, Digital Image Correlation) 플랫폼을 설계하고, 계측에 영향을 주는 영상 품질을 분석하였다. DIC 플랫폼은 Freescale사의 I.MX6를 기반으로 설계하였다. 영상 상관을 이용한 계측은 영상의 품질에 따라 계측 정밀도에 영향을 줄 수 있는데, 이러한 영상 품질 요인으로 영상의 밝기(brightness), 대조(contrast), 신호대 잡음비(SNR, Signal to Noise Ratio)를 분석하였다. 관심 영역(ROI, Region Of Interest)으로 설정한 부분에서 추출한 영상을 기준 영상으로 삼고, 일정 시간 경과 후 디지털 영상 상관(DIC)을 이용하여 기준 영상의 이동을 화소 및 부화소 단위로 추적 계산하여 변위를 측정하였다. 더불어 DIC 기반의 비접촉 원격 계측의 유효성을 파악하기 위하여 25m, 35m, 50m의 계측 거리에서, 영상 품질 요인 및 ROI 의 크기를 조정하여 측정을 하고 정밀도를 분석하였다.

Fingerprint Verification Based on Invariant Moment Features and Nonlinear BPNN

  • Yang, Ju-Cheng;Park, Dong-Sun
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권6호
    • /
    • pp.800-808
    • /
    • 2008
  • A fingerprint verification system based on a set of invariant moment features and a nonlinear Back Propagation Neural Network(BPNN) verifier is proposed. An image-based method with invariant moment features for fingerprint verification is used to overcome the demerits of traditional minutiae-based methods and other image-based methods. The proposed system contains two stages: an off-line stage for template processing and an on-line stage for testing with input fingerprints. The system preprocesses fingerprints and reliably detects a unique reference point to determine a Region-of-Interest(ROI). A total of four sets of seven invariant moment features are extracted from four partitioned sub-images of an ROI. Matching between the feature vectors of a test fingerprint and those of a template fingerprint in the database is evaluated by a nonlinear BPNN and its performance is compared with other methods in terms of absolute distance as a similarity measure. The experimental results show that the proposed method with BPNN matching has a higher matching accuracy, while the method with absolute distance has a faster matching speed. Comparison results with other famous methods also show that the proposed method outperforms them in verification accuracy.

Stripmap SAR 신호처리를 위한 PGA 적용 기법 (PGA Implementation Technique for Stripmap SAR Signal Processing)

  • 윤상호;고보연;공영균;신희섭
    • 대한원격탐사학회지
    • /
    • 제27권2호
    • /
    • pp.151-161
    • /
    • 2011
  • SAR(Synthetic Aperture Radar) 영상의 화질을 개선하기 위한 autofocus 기법 중에 대표적 인 것이 PGA(Phase Gradient Autofocus) 이다. PGA는 고차항 위상 오차를 추정할 수 있으며 잡음이 많은 환경에 강인성을 가지는 장점이 있지만, spotlight 모드에 최적화 되어있는 기법으로 stripmap 모드에서 사용하기에는 부적합하다는 단점이 있다. 본 논문에서는 PGA를 stripmap 모드에서 적용한 기법을 소개하고, PGA 성능에 많은 영향을 미치는 ROI(Region of Interest) 선정 방식을 제시하였다. 또한 제안된 기법은 먼저 점표적 시뮬레이션을 통해 검증되었고, 최종적으로 이를 실제 비행 시험을 통해 획득한 SAR 원시데이터에 적용하여 SAR 영상 화질을 개선시킨 결과를 보였다.

Aircraft Motion Identification Using Sub-Aperture SAR Image Analysis and Deep Learning

  • Doyoung Lee;Duk-jin Kim;Hwisong Kim;Juyoung Song;Junwoo Kim
    • 대한원격탐사학회지
    • /
    • 제40권2호
    • /
    • pp.167-177
    • /
    • 2024
  • With advancements in satellite technology, interest in target detection and identification is increasing quantitatively and qualitatively. Synthetic Aperture Radar(SAR) images, which can be acquired regardless of weather conditions, have been applied to various areas combined with machine learning based detection algorithms. However, conventional studies primarily focused on the detection of stationary targets. In this study, we proposed a method to identify moving targets using an algorithm that integrates sub-aperture SAR images and cosine similarity calculations. Utilizing a transformer-based deep learning target detection model, we extracted the bounding box of each target, designated the area as a region of interest (ROI), estimated the similarity between sub-aperture SAR images, and determined movement based on a predefined similarity threshold. Through the proposed algorithm, the quantitative evaluation of target identification capability enhanced its accuracy compared to when training with the targets with two different classes. It signified the effectiveness of our approach in maintaining accuracy while reliably discerning whether a target is in motion.

Assessment of the Cerebrospinal Fluid Effect on the Chemical Exchange Saturation Transfer Map Obtained from the Full Z-Spectrum in the Elderly Human Brain

  • Park, Soonchan;Jang, Joon;Oh, Jang-Hoon;Ryu, Chang-Woo;Jahng, Geon-Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.139-149
    • /
    • 2019
  • Purpose: With neurodegeneration, the signal intensity of the cerebrospinal fluid (CSF) in the brain increases. The objective of this study was to evaluate chemical exchange saturation transfer (CEST) signals with and without the contribution of CSF signals in elderly human brains using two different 3T magnetic resonance imaging (MRI) sequences Methods: Full CEST signals were acquired in ten subjects (Group I) with a three-dimensional (3D)-segmented gradient-echo echo-planar imaging (EPI) sequence and in ten other subjects (Group II) with a 3D gradient and spin-echo (GRASE) sequence using two different 3T MRI systems. The segmented tissue compartments of gray and white matter were used to mask the CSF signals in the full CEST images. Two sets of magnetization transfer ratio asymmetry (MTRasym) maps were obtained for each offset frequency in each subject with and without masking the CSF signals (masked and unmasked conditions, respectively) and later compared using paired t-tests. Results: The region-of-interest (ROI)-based analyses showed that the MTRasym values for both the 3D-segmented gradient-echo EPI and 3D GRASE sequences were altered under the masked condition compared with the unmasked condition at several ROIs and offset frequencies. Conclusions: Depending on the imaging sequence, the MTRasym values can be overestimated for some areas of the elderly human brain when CSF signals are unmasked. Therefore, it is necessary to develop a method to minimize this overestimation in the case of elderly patients.

차량 그림자 누적을 통한 검지 영역 자동 설정 및 교통량 측정 방법 (Automatic Detection of Vehicle Area Rectangle and Traffic Volume Measurement through Vehicle Sub-Shadow Accumulation)

  • 김지완;이재성
    • 한국정보통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.1885-1894
    • /
    • 2014
  • 기존 영상 검지기 분야에는 다양한 고성능 알고리즘들이 존재하지만 실시간 연산 요구량이 너무 많아 시스템 장비가 고가, 고전력을 소모하는 단점이 있었다. 이에 본 논문에서는 저가, 저전력 영상 검지 시스템 구현을 위해 안드로이드 플랫폼의 성능 사양에 적합한 저연산량의 영상 검지 알고리즘을 제안한다. 본 방법은 차량 하부에만 생성되는 sub-shadow 를 분리하여 이를 누적함으로써 차선 및 검지 영역을 정밀하게 설정하고 이 검지 영역을 통과하는 차량 자체와 차량 sub-shadow 의 통과패턴을 판단하여 차선별 교통량 뿐만 아니라 상행 및 하행 교통량까지 자동으로 분류할 수 있다. 실험 결과 제안하는 알고리즘은 하행 차량의 경우 평균 97.1%, 상행 차량의 경우 평균 94.1%의 검지율을 보였다. 이 결과는 상용 루프검지기의 성능 95% 에 버금가는 수준으로 만족스러운 성능을 보였다.

갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구 (Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans)

  • 김정수;김근우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

국부이진패턴 히스토그램을 이용한 측면 차량 검출 (Passing Vehicle Detection using Local Binary Pattern Histogram)

  • 강형섭;조동찬;고 경우;김회율
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2010년도 하계학술대회
    • /
    • pp.260-263
    • /
    • 2010
  • 본 논문에서는 주행 중인 차량에서 전방을 향해 장착된 카메라를 통해 입력된 영상에서 측면에 부분적으로 나타나는 차량을 검출하는 방법을 제안한다. 기존 연구에서는 모션 벡터를 이용하여 주변 배경과 관측되는 차량 사이의 모션 벡터 차이를 이용하여 측면 차량을 검출하고 있다. 그러나 모션 벡터를 이용할 경우 정지된 차량이나 전방에서 다가오는 차량의 경우 검출하기 어려운 점이 있다. 이러한 문제를 해결하기 위해 본 논문에서는 모션 벡터를 사용하지 않고 차량 측면 모습에서 특징 정보를 추출하여 SVM 분류기를 통해 측면 차량을 검출하는 방법을 제안한다. 차량 측면 모습의 특징을 뽑기 위해 영상의 밝기 변화에 강인한 국부 이진 패턴을 사용하였고 ROI영역 내에서 차량이 나타나는 위치에 상관없이 차량의 측면 모습을 찾아내기 위해 국부 이진 패턴의 히스토그램을 이용하였다. 실험결과에서는 제안하는 방법이 정지된 차량을 포함하여 88.5%의 정확도로 측면 차량을 검출하는 것을 확인하였다.

  • PDF