• Title/Summary/Keyword: Structure Vibration

Search Result 4,332, Processing Time 0.029 seconds

Seismic response control of irregular asymmetric structure with voided slabs by distributed tuned rotary mass damper devices

  • Shujin Li;Irakoze Jean Paula;Ling Mao
    • Earthquakes and Structures
    • /
    • v.25 no.6
    • /
    • pp.455-467
    • /
    • 2023
  • This study focuses on demonstrating the effectiveness of vibration control of tuned rotary mass damper (TRMD) for reducing the bidirectional and torsional response of the irregular asymmetric structure with voided slabs under earthquake excitations. The TRMD arranged in plane of one-story eccentric structure is proposed as a distributed tuned rotary mass damper (DTRMD) system. Lagrange's equation is used to derive the equations of motion of the controlled system. The optimum position and number of TRMD are numerically investigated under harmonic excitation and the control effects of different distributions are discussed. Furthermore, a shaking table test is conducted under different excitation cases, including free vibration, forced vibration and seismic wave to investigate the absorption performance of the device. The numerical simulations of different distributions of the TRMDs show that the DTRMDs are more effective in reduction of the displacement response of the asymmetric structure under the same mass ratio, even when the degree of eccentricity becomes large. However, with small degree of eccentricity, the unreasonable asymmetrical arrangement may cause the increase of the peak value of the rotational angular displacement. Finally, the experimental investigations exhibit similar results of translational displacement of the structure. It is concluded that the vibration of the irregular asymmetric structure can be controlled more economically and effectively by reducing the mass ratio through reducing the quantity of TRMDs at the high stiffness end.

Tuned mass dampers for human-induced vibration control of the Expo Culture Centre at the World Expo 2010 in Shanghai, China

  • Lu, Xilin;Ding, Kun;Shi, Weixing;Weng, Dagen
    • Structural Engineering and Mechanics
    • /
    • v.43 no.5
    • /
    • pp.607-621
    • /
    • 2012
  • The Expo Culture Centre is one of the permanent buildings at the World Expo 2010 in Shanghai, China. The main structure has an oval shape and consists of 36 radial cantilever steel trusses with different lengths and inner frames made of concrete-filled rectangular steel tube members. Tuned mass dampers are used to reduce the excessive vibrations of the sixth floor that are caused by human-induced resonance. A three-dimensional analytical model of the system is developed, and its main characteristics are established. A series of field tests are performed on the structure, and the test results show that the vertical vibration frequencies of most structural cantilevers are between 2.5 Hz and 3.5 Hz, which falls in the range of human-induced vibration. Twelve pairs of tuned mass dampers weighing 115 tons total were installed in the structure to suppress the vibration response of the system. These mass dampers were tuned to the vertical vibration frequency of the structure, which had the highest possibility of excitation. Test data obtained after the installation of the tuned mass dampers are used to evaluate their effectiveness for the reduction of the vibration acceleration. An analytical model of the structure is calibrated according to the measured dynamic characteristics. An analysis of the modified model is performed and the results show that when people walk normally, the structural vibration was low and the tuned mass dampers have no effect, but when people run at the structural vibration frequency, the tuned mass dampers can reduce the floor vibration acceleration by approximately 15%.

The actuation equation of macro-fiber composite coupled plate and its active control over the vibration of plate and shell

  • Tu, Jianwei;Zhang, Jiarui;Zhu, Qianying;Liu, Fan;Luo, Wei
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.297-311
    • /
    • 2018
  • Plate and shell structure is widely applied in engineering, i.e. building roofs, aircraft wings, ship platforms, and satellite solar arrays. Its vibration problem has become increasingly prominent due to the tendency of lightening, upsizing and flexibility. As a new smart material with great actuating force and toughness, macro-fiber composite (MFC) is composed of piezoelectric fiber and epoxy resin basal body, which can be directly pasted onto the surface of plate and shell and is suitable for vibration control. This paper deduces the actuation equation of MFC coupled plate in different boundary conditions, an equivalent finite element modeling method is proposed which uses MFC actuating force as the applied excitation, and on this basis the active control simulation and experiment of MFC over plate and shell structure vibration are accomplished. The results indicate that MFC is able to implement effective control over plate and shell structure vibration in multi-band range. The comparison between experiment and simulation proves that the actuation equation deduced herein, effective and practicable, can be applied into the simulation calculation of MFC vibration control over plate and shell structure.

Vibration Control of Beam using Distributed PVDF Sensor and PZT Actuator (분포형 압전필름 감지기와 압전세라믹 작동기를 이용한 보의 진동 제어)

  • 유정규;박근영;김승조
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.967-974
    • /
    • 1997
  • Distributed piezoeletric sensor and actuator have been designed for efficient vibration control of a cantilevered beam. Both PZT and PVDF have been used in this study, the former as an actuator and the latter as a sensor for the integrated structure. We have optimized the position and the size of the PZT actuator and the electrode shape of the PVDF sensor. Finite element method is used to model the structure and the optimized actuators, we have designed the active electrode width of the PVDF sensor along the span of the beam. Actuator design is based on the criterion of minimizing the system energy in the control modes under a given initial condition. Model control forces for the residual (uncontrolled) modes have been minimized during the sensor design to minimize the observation spill-over. Genetic algorithm and sequential quadratic programming technique have been utilized as an optimization scheme. Discrete LQG control law has been applied to the integrated structure for real time vibration control. Performance of the sensor, the actuator, and the integrated smart structure has been demonstrated by experiments.

  • PDF

A Dynamic Analysis and Evaluation of a Building Structure due to Tunnel Blast by using Semi-Empirica Method (준경험적 방법을 이용한 터널발파 작업시 인접구조물의 동적해석 및 진동영향성 평가)

  • Son, Sung-Wan;Ru, Kuk-Hyun;Chun, Jong-Kun;Nam, Young-Sik;Kim, Dong-Gi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.772-775
    • /
    • 2005
  • Most engineers, related to soil and civil dynamic field, have been interested in the direct dynamic design of building transmitted from soil and rock to structure due to blasting. However it is not easy to estimate the dynamic response of structures due to blasting by using analytical method because of difficulties of soil modeling, prediction of excitation force and so on. In this paper, dynamic analysis have been performed to predict vibration level and evaluate dynamic safety of structure adjacent to tunnel blast and the semi empirical method, which is based on vibration measurement data, has been employed to consider blast vibration characteristics.

  • PDF

Comparison of the Multiple PPF Control and the Modified LQG Control for the Active Vibration Suppression of Intelligent Structures (지능구조물의 능동진동제어를 위한 다중 PPF 제어기와 수정 LQG 제어기의 비교 연구)

  • 곽문규
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1121-1129
    • /
    • 1998
  • This research is concerned with the multiple PPF and the modified LQG controller design for active vibration control of intelligent structures. The intelligent structure is defined as the structure equipped with smart actuators and sensors. Various control techniques aimed for the piezoceramic sensors and actuators have been proposed for the active vibration control of smart structures and some of them prove their effectiveness experimentally. In this paper, the multiple PPF controller and the modified LQG controller are developed and applied to the smart grid structure. The multiple PPF control and the modified LQG control can be classified as the classical and the modern control techniques. respectively. The experimental results show that both control techniques are effective in suppressing vibrations. Two control techniques are compared with respect to the design process. the ease of implementation and the effectiveness

  • PDF

Time Historical Response Analysis of Tree Structure by Transfer Stiffness Coefficient Method (전달강성계수법에 의한 분기형 구조물의 시긴이력응답해석)

  • 문덕홍;강현석;최명수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.426-431
    • /
    • 1998
  • This, paper describes formulation for time historical response analysis of vibration for tree structure. This method is derived from a combination of the transfer stiffness coefficient method and the Newmark-.betha. method. And This present method improves the computational accuracy of the transient vibration response analysis remarkably owing to several advantages of the transfer stiffness coefficient method. We regarded the structure as a lumped mass system here. The analysis algorithm for the time historical response was formulated for the tree structure. The validity of the present method compared with the transfer matrix method and the FEM(Finite Element Method) for transient vibration analysis is demonstrated through the numerical computations.

  • PDF

Experimental Method of a Super Structure (선체 상부구조물의 실험적 해석)

  • 박석주;박성현;오창근;제해광
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.328-334
    • /
    • 2001
  • Up to now. vibration analysis and vibration engineering have been developed, encompassing the aspects of both experimental and analytical techniques. Using experimental modal analysis or modal testing, the mode shapes and frequencies of practical structure can be measured accurately. Curve-Fitting Method is realized through experimental modal identification. In the experimental modal parameter estimation, the estimation of modal damping factor is difficult for complicated and large structure. Also numbers of Selected mode are determined before the procedure. This paper describes the vibration shape of the super-structure model of ship through experimental modal analysis.

  • PDF

The dynamic response prediction of the structure by transient vibration using Semi-Empirical Method (준 경험적 방법을 이용한 충격성 진동에 대한 구조물의 동적 응답의 예측)

  • Lee, Hong-Ki;Baek, Jae-Ho;Kim, Kang-Boo;Woun, Young-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1945-1950
    • /
    • 2000
  • When one build a building that posses Precison production process to be sensitive to vibration and SMD to procuce a large dynamic force, how do one predict & answer vibration control problem at building structure design at first stage, That is a question. It has tried to predict dynamic response and establish answering about global or local dynamic problem in building using experimental and analysis method. One of such a try, it be proposed Semi-Empirial Method that reduce error element of input information about dynamic analysis using dynamic experimental study and measurement data in the basis of real-structure. In this paper, the dynamic response problem about RC-structure building that will be set-up SMD produce large transient dynamic force using Semi-Empirical Method.

  • PDF

Vibration Analysis of Bus Structure using Sensitivity Analysis of Bus Component Structures (부분 구조물의 민감도 분석을 이용한 버스차체의 진동분석)

  • Lee, Sang-Beom
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.355-361
    • /
    • 2009
  • In this paper, an analysis technique is presented for performing the effective design of bus structure. Sensitivity analysis is carried out for the natural frequency of component structures consisting of bus B.I.W. Local vibration modes of substructure, which large affect on the global vibration mode of the bus B.I.W., are obtained through the sensitivity analysis technique using the mathematical chain rule. And also the design variables, which are determined from the sensitivity analysis, are redesigned through optimum design process. The proposed analysis technique shows that the bus structure can be effectively designed considering the vibration characteristics.

  • PDF