• Title/Summary/Keyword: Structural Weight

Search Result 2,484, Processing Time 0.028 seconds

A Study on the Applicability of Partial Post-Tension Slab with Top Anchorage System (상향긴장식 부분PT를 사용한 슬래브의 적용성 분석)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Chang-Hyuk;Kim, Sang-Sik;Kim, Yong-Nam;Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.309-312
    • /
    • 2008
  • Reinforced concrete (RC) structures have been most widely used because of the economic efficiency. However, it is very weak to tensile stresses and difficult to control deflection due to the heavy self-weight of concrete. Although it is generally known that prestressed concrete structures can be the most effective to overcome the demerit of RC structures, its application is very seldom in domestic construction for the difficult onsite circumstances. The post-tension method, which is well fit for buildings that are mostly indeterminate structures and beneficial for monolithic construction, has been introduced to just a few building construction. The application of full PT method into entire spans makes construction engineers feel very difficult due to the lack of current condition in construction fields. Therefore, this study proposed the partially applied PT method as an alternative, which can improve the deflection control of RC structures and reduce the construction difficulty by applying the PT method in a part of span length as needed, and analyzed its characteristics of structural behavior. In this study, the top anchorage was applied to improve the applicability of partial PT method, and the analysis results of slab behavior were compared to the measured values obtained from the post-tensioned slab constructed by the partial PT method.

  • PDF

Correlation Analysis of Sewer Integrity and Ground Subsidence (하수관로 건전도와 도로함몰 발생 상관관계 분석)

  • Kim, Jinyoung;Kang, Jaemo;Choi, Changho;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.6
    • /
    • pp.31-37
    • /
    • 2017
  • In recent years, the increasing trend of ground subsidence in major cities has caused social problems. Aged sewer pipeline as a main attribute for the subsidence is simply replaced and maintained according to a survey result with related to its buried period. However, other attributes and risk analysis for the subsidence have not been well studied yet. In this point, this study proposed various environmental and structural attributes with related to sewer pipelines and, then, a method of ground subsidence risk evaluation with a certain level of reliability. In order to find effective attributes to ground subsidence near to sewer, the nearest sewerage data were extracted at the location of subsidence in the City of Seoul, and a level of correlation was analyzed between subsidence and individual attribute. The effective weight factors for the proposed attributes was estimated through AHP analysis and its applicability was verified by comparing the actual subsidence data to the risk evaluation in the pilot study district of Seoul.

Flexural Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 휨성능)

  • Hwang, Seung-bum;Seo, Soo-yeon;Lee, Kang-cheol;Lee, Seok-hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.3-11
    • /
    • 2016
  • The concern about hollow core PC slab has been increased to improve the workability during a construction of building by reducing self weight of structural members. In this manner, recently, TRS (Tripple Ribs Slab) was developed as a new type of half PC slab system. TRS member consists of the triple webs and the bottom flange prestressed by strands. The slab system is completed by casting of topping concrete on the TRS after filling styrofoam between the webs. This paper, presents a flexural experiment to investigate the flexural capacity of the TRS. Five full scale TRS members were made and tested under simple support condition to be failed by flexure and their strength was evaluated by code equations; the variables in the test are the depth and the presence of topping or raised spot formed when slip-forming. In addition, a nonlinear sectional analysis was performed for the specimens and the result was compared with the test results. From the study, it was found that the TRS has enough flexural strength and ductility to resist the design loads and its strength can be suitably predicted by using code equations. The raised spot did not affect the strength so that the spot need not to be removed by doing additional work. For the more accurate prediction of TRS's flexural behavior by using nonlinear sectional analysis, it is recommended to consider the concrete's brittle property due to slip-forming process in the modeling.

Static Behavior of Stud Shear Connector for UHPC Deck (초고성능 콘크리트 바닥판을 위한 스터드 전단연결재의 정적 거동)

  • Lee, Kyoung-Chan;Kwark, Jong-Won;Park, Sang-Hyeok;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.573-579
    • /
    • 2014
  • Typical composite girder has been composed with conventional concrete deck and steel girder. Recently, ultrahigh-performance-concrete (UHPC) deck is proposed in order to enhance durability and reduce weight of deck as well as to increase stiffness and strength of the composite girder. This study investigates that a headed stud is still compatible as a shear connector for the UHPC deck and steel girder composite beam. Twelve push-out specimens are prepared to evaluate the static strength of stud shear connectors embedded in the UHPC deck. The test program proves that the static strength of the stud shear connectors embedded in UHPC well meets with design codes described in AASHTO LRFD. Chosen experimental variables are aspect ratio of height to diameter of stud, thickness of deck and thickness of concrete cover over the head of stud. From the test program, aspect ratio and cover thickness are investigated to mitigate the regulations of the existing design codes. The minimum aspect ratio and the minimum cover thickness given in AASHTO LRFD are four and 50mm, respectively. This limitation hinders to lower the thickness of the UHPC deck. The results of the experiment program give that the aspect ratio and the cover thickness can be lower down to three and 25mm, respectively. Eurocode-4 regulates characteristic relative slip at least 6mm. However, test results show that stud shear connectors embedded in UHPC provide the characteristic relative slip only about 4mm. Therefore, another measures to increase ductility of stud should be prepared.

Torsional Behavior of Hybrid Truss Bridge according to Connection Systems (복합트러스교의 격점구조별 비틀림 거동)

  • Jung, Kwang-Hoe;Lee, Sang-Hyu;Yi, Jong-Won;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.63-72
    • /
    • 2013
  • HTB (hybrid truss bridge) steel truss webs instead of concrete webs in prestressed box girder bridges has been widely used in, because of its structural benefit such as relatively less self-weight and good aesthetics due to open web structure. Since the core technology of this bridge is the connection system between concrete slabs and steel truss members, several connection systems were proposed and experimentally evaluated. Also, the selected joint system was applied to the real bride design and construction. The researches were performed on the connection system, since it can affect the global behavior of this bridge such as flexural and fatigue behaviors as well as the local behavior around the connection region. The evaluation study showned that HTB applied to a curved bridge or a eccentric loading bridge, characteristic has a weak torsional capacity compared to an ordinary PSC box girder bridges due to the open structure of HTB. In this study, three box shaped hybrid truss specimens were made and the torsional test and evaluation for them were performed in order to find out the torsional behavior of HTB according to the connection system.

A Experimental Study on the Determination of Construction method of Controled Low-strength Material Accelerated Flow Ability Using Surplus Soil for Underground Power Line (지중송전관로용 급결 유동성 뒤채움재의 시공법 설정에 관한 실험적 연구)

  • Oh, Gi-Dae;Kim, Dae Hong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.84-93
    • /
    • 2010
  • Compaction of backfill material of Underground power lines is difficult, especially under pipeline. so it could cause structural problem because of low compaction efficiency. So various methods have been taken to solve the problem and one of them is CLSM(Controled low-strength material accelerated flow ability). But In other countries, these are already in progress for a long time to research and development and recently on practical steps. But, in our country, study for only general structures, not for underground power line structure that is being constructed at night rapidly. In this study, we performed property tests and indoor & outdoor test (3 cases). The tests showed flow ability reached at the limit construction(160 mm) flowability by 9 to 15 minute after starting to mix, and construction buoyant is lowering after placing CLSM by 70 % of theoretical buoyant that is calculated by unit weight of material. In this paper, we performed indoor tests and outdoor tests to estimate mechanical properties and to suggest construction method(using batch plant, setting spacer at 1.8 m and placing at 2m) for CLSM that using surplus soil. And the test showed good results for construction quality, workability and structure safety.

  • PDF

Shape Optimization of the Plane Truss Structures with the Statical and Natural Frequency Constraints (정적(靜的) 및 고유진동수(固有振動數) 제약조건식(制約條件式)을 고려(考慮)한 평면(平面) 트러스 구조물(構造物)의 형상최적화(形狀最適化)에 관(關)한 연구(硏究))

  • Lee, Gyu Won;Lee, Gun Tea
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.23-38
    • /
    • 1990
  • In this study, decompositive optimization method of two levels was selected to optimize effectively the geometry of the truss which takes the multi-loading condition, and the allowable stress, bucking stress, displacement and natural frequency constraints into consideration. The algorithm of this study is made up of sectional optimization using the feasible direction method in level 1, and geometrical optimization employing Powell's one-direction search method which menimizes only objictive function in level 2. The results of this study acquired by beenning applied to structural model of the truss are as follows : 1. It is verified that the algorithm of this study effectively converges, independent of the initial geometry of the truss and the applied various constraints. 2. The optimum goemetry of the truss varies more considerably according to the constraints selected. 3. Under the condition of the same design, the weight of the truss can be decreased more considerably by means of optimizing even the geometry of truss than by means of optimizing the section of truss while fixing geometrical configuration of it, even though there might be a little difference according to the initial geometry of the truss and the design condition.

  • PDF

Effects of productivity of Lentinula edodes according to the control of high-temperature environment in summer (여름철 표고 톱밥재배의 고온환경조절이 버섯생산성 향상에 미치는 영향)

  • Kim, In-Yeop;Kim, Seon-Cheol;Noh, Jong-Hyun;Choi, Sun-Gyu;Lee, Won-Ho;Ko, Han-Gyu;Park, Heung-Soo;Koo, Chang-Duk
    • Journal of Mushroom
    • /
    • v.13 no.4
    • /
    • pp.288-293
    • /
    • 2015
  • In the structural investigation of cultivation facilities, the proportion of farmers to grown with double or triple structure were investigated 96%. It has been shown to grow with a stable cultivation facilities structure against environmental changes. The results of the analysis of the changes in the cultivation environment of Yeoju area in July-august, temperature and humidity of the external instrument shelter was $20.2{\sim}29.9^{\circ}C$ and 66.2~99.9% respectively. In the greenhouse 2 model capable of temperature environment regulation in the cultivation facility, temperature and humidity were investigated $19.3{\sim}25.7^{\circ}C$ and 81.6~99.9% respectively. Result of the survey of fruiting body characteristics and yields in the greenhous 2, pileus diameter and stipe length were investigated 66.2 and 54.1 mm, yield of mushroom and individual weight were 312 g and 26.6 g. High-temperature environment regulation shows the improvement of the quality and productivity of the mushroom. Power consumption of the air conditioning has been investigated using 56kwh/day, electricity costs were calculated 2195 won/day.

The Mechanism to Oxidative Polymerization of N-Methyl-p-Aminophenol and Thermal Characteristics of the Polymer Formed (N-Methyl-p-Aminophenol의 酸化重合機構 및 生成重合體의 熱特性)

  • Choi Kyu Suck
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.314-319
    • /
    • 1972
  • N-Methyl-p-aminophenol was polymerized by oxidative couplng in the aqueous iron chelate solution in the presence of oxygen, and black precipitate of oligo-(N-methyl-p-aminophenol) was formed quantitatively. In this oxidative polymerization reaction, methyl group attached to N in the monomer was partly eliminated, and it was clarified by the infrared spectra from the fact that the absorption of ${\delta}\;asym\;CH_3\;1460\;cm^{-1}$ and ${\delta}\;sym\;CH_3\;1380\;cm^{-1}$ in acetone insoluble fraction was much weaker than that in acetone soluble fraction. From Thermo-gravimetric analysis, oligo-(N-methyl-p-aminophenol) showed about 40% weight loss at $600^{\circ}C$ and it was less heat-resistant than oligo (p-aminophenol) that methyl group was not contained. In pyrolysis of oligo-(N-methyl-p-aminophenol) in He atmosphere, monomer N-methyl-p-aminophenol and water were formed, and in the pyrolytic gases, $H_2,\;CO,\;CO_2$ were detected by gas chromatography. From the above facts, to the structural change on oligo-(N-methyl-p-aminophenol) when it was heat-treated, it was considered that original linear structure was partly degraded, and the most of the oligomer was to go in with melt polycondensation to form polymer, and heat-resistant cyclic structure was formed at a time.

  • PDF

The Stress-Strain Properties of No-Fines Lightweight Concrete Using Synthetic Lightweight Coarse Aggregate (인공경량조골재(人工輕量粗骨材)를 사용(使用)한 무세골재(無細骨材) 경량(輕量)콘크리트의 응력(應力)-변형특성(變形特性))

  • Min, Jeong Ki;Kim, Seong Wan;Sung, Chan Yong;Kim, Kyung Tae
    • Korean Journal of Agricultural Science
    • /
    • v.23 no.1
    • /
    • pp.120-130
    • /
    • 1996
  • Concrete is the most commonly used structural materials, but in concrete construction, its self-weight represents a very large proportion of the total load on the structure, and there are clearly considerable advantages in reducing the density of concrete. This study was carried out to investigate the stress-strain properties of no-fines synthetic lightweight concrete with synthetic lightweight coarse aggregates. The used synthetic lightweight coarse aggregate were two types, one was expanded clay with grading 3~8mm, the other is pumice stone with grading 4.75~10mm. The results of this study were summarized as follows ; The static modulus of elasticity of the synthetic lightweight concrete was $1.8{\times}10^5kg/cm^2$ at type CE using the expanded clay and $1.6{\times}10^5kg/cm^2$ at type CL using the pumice stone. The dynamic modulus of elasticity was $1.9{\times}10^5kg/cm^2$(CE) and $2.0{\times}10^5kg/cm^2$(CL). The dynamic modulus of elasticity was 10~30% larger than that of the static modulus of elasticity. The load-time curves of synthetic lightweight concrete were shown approximately similar to each other type except for added foaming agent. The stress-strain curves in uniaxial compressive of synthetic lightweight concrete were similar to each other.

  • PDF