• Title/Summary/Keyword: Structural Evaluation Test

Search Result 1,330, Processing Time 0.027 seconds

Estimation of Dynamic Parameters and Concrete Strength of a Structural Member by Impact Hammer Testing (임팩트해머 실험에 의한 부재의 동적파라미터 및 콘크리트 강도 추정)

  • Sehee Kim;Junghyun Kyung;Heechang Eun
    • Land and Housing Review
    • /
    • v.15 no.3
    • /
    • pp.153-164
    • /
    • 2024
  • Structural health monitoring involves performance evaluation based on measurements for maintenance purposes. By back-calculating measured Frequency Response Function (FRF) data, the concept of effective mass was introduced and applied to the performance evaluation of structural members. An identification method was proposed that uses participation factors to estimate the dynamic parameters and the strength of concrete of structural members. The appropriateness of these methods for identifying dynamic parameters and concrete strength of structural members was validated through experimental results, proving their utility in non-destructive testing for concrete strength.

Safety evaluation of rubber-tired AGT light rail vehicle-running track (고무차륜 AGT 경량전철 차량-주행궤도 안전성 평가)

  • Lim T.K.;Kim Y.S.;Lee A.H.;Kim J.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1644-1647
    • /
    • 2005
  • This study was aimed at evaluating the structural safety for rubber tired AGT system. Based on these, AGT system which was developed for first time in domestic is need to verify structural safety. So we measured the characteristics of guide-rail, switch rail, side wall in the constructed test track for rubber tired AGT system. Finally, all results of test showed that structural safety of the rubber tired AGT system.

  • PDF

Study on the Structural Strength of Deep Well Rail Car in Railway Applications (철도적용에서 곡형차량의 구조강도에 관한 연구)

  • Yoon, Sung Cheol;Kim, Jeongguk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.4
    • /
    • pp.317-324
    • /
    • 2016
  • Stress tests were conducted in the carbody of the railroad car to check the structural strength of the body of the railroad car. The objective of this study was to evaluate safety of the carbody of a railroad car under the maximal strength. The carbody of rolling stock is a principal structure that supports major equipment of the underframe and the freight. Therefore, the strength evaluation of this structure is important. This study was carried out to analyze the structure of carbody and evaluate safety under maximum vertical load, compressive load, and torsional load. Accordingly, stress tests were conducted on the carbody to measure the stress on each of their parts. Before the load test, a structural-analysis program was used for the stress distribution analysis of the body structure.

The Evaluation on Wear Characteristics of the Crane Sheave (크레인용 시브 강재의 마멸특성 평가)

  • Park Yongjae;Ryu Jungbuk;Kim Seocksam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.306-311
    • /
    • 2004
  • The sliding wear characteristics of the crane sheave were investigated using a pin-on-disk rig tester The experiment was conducted using a high carbon steel wire that was upper material, also carbon steel castings and carbon steel for machine structural use that was disk material. There are various operating conditions in this work. At the room temperature, we carried out the wear test under a grease lubrication. The results of wear test showed that carbon steel for machine structural use have lower wear volume, also the wear curves are linearly increased with increasing of sliding velocity The wear mechanism of a disk is the abrasive, adhesion, and fatigue wear under lubrication.

  • PDF

An Evaluation of Structural Strength by Testing the Carbody of Light Composite Material (경량 복합소재 차체의 시험에 의한 구조강도 평가)

  • Yoon S.C.;Jeon C.S.;Kim W.K.;Kim M.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.393-394
    • /
    • 2006
  • This study introduces the testing results of the composite carbody which is applied to tilting train. The composite carbody is made of aluminum honeycomb structure materials like a sandwich. The static load test was performed to evaluate the structural characteristic and stability of the composite carbody. Considering the vertical, compressive, twisting load and 3-point supporting type as a testing terms, the structural stability of a carbody was evaluated.

  • PDF

Evaluation of Static/Dynamic Structural Strength for Automotive Round Recliner (자동차용 라운드 리클라이너 정적/동적 구조 강도 평가)

  • Lee Dongjae;Park Changsoo;Lee Kyoungteak;Kim Sangbum;Kim Heonyoung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.140-146
    • /
    • 2005
  • This study presents the development of a round recliner using the finite element method. That reduces the number of test repeating times and gives an information about stiffness. A simulation model of round recliner mounting seat module and tooth strength simulation are established using a PAM-CRASH and ABAQUS. With the optimization of gear profile, structural strength design of round recliner was achieved. The round recliner seat module simulation, structure strength simulation and a crash safety are requested by FMVSS test. Solution of round recliner optimum variable study and design problem are searched for round recliner stress, deformation and application. Also an examination of safety is made.

Studies on the heat performance and stability for multi spray type desuperheater of the power plant (발전소용 다중 스프레이형 과열저감기의 열성능 및 안정성에 관한 연구)

  • Cho, Nam-Cheol;Lee, Deok-Gu;Lee, Chae-Moon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.185-190
    • /
    • 2011
  • The important use of the desuperheater(multi spray type) changes the superheated steam into the saturated steam. It is more efficient and suitable for using the process. Also, it is more convenient and stable regarding the process temperature control. In this study, transient and quasi-static analysis were done for the evaluation of structural integrity of the multi spray type desuperheater of the power plant. Computational analysis was used to calculate the thermal stress, and the vibration test was done to evaluate the structural stability. This paper is verified by analysis that water spray nozzle(${\phi}=28mm$) shows the best ability. The results show that structural stability of the desuperheater under the real operating condition was proven.

  • PDF

Proof Load Test and Integrity Assessment of Segmental PC Box-girder Bridges (Segmental PC 박스거더교의 검증재하시험 및 건전성평가)

  • 조효남;임종권;옥승범;지광습
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.132-141
    • /
    • 1995
  • This study is intended to propose practical but systematic and rational approaches for proof load test and integrity assessment of segmental PC box-girder bridges. The proposed models cover the whole range of field tests and assessment of such as inspections, nondestructive tests, static and dynamic load tests, structural analysis, and integrity assessment for the evaluation of load carrying capacity, serviceability, and durability of PC box-girder bridges. They are applied to a newly constructed precast segmental PC box-girder bridge which is a part of the Seoul interior circuit elevated expressway.

  • PDF

Structural evaluation of an existing steel natatorium by FEM and dynamic measurement

  • Liu, Wei;Gao, Wei-Cheng;Sun, Yi;Yu, Yan-Lei
    • Structural Engineering and Mechanics
    • /
    • v.31 no.5
    • /
    • pp.507-526
    • /
    • 2009
  • Based on numerical and experimental methods, a systematic structural evaluation of a steel natatorium in service was carried out in detail in this paper. Planning of inspection tasks was proposed firstly according to some national codes in China in order to obtain the economic and reliable results. The field visual inspections and static computation were conducted in turn under in-service environmental conditions. Further a three-dimensional finite element model was developed according to its factual geometry properties obtained from the field inspection. An analytical modal analysis was performed to provide the analytical modal properties. The field vibration tests on the natatorium were conducted and then two different system identification methods were used to obtain the dynamic characteristics of the natatorium. A good correlation was achieved in results obtained from the two system identification methods and the finite element method (FEM). The numerical and experimental results demonstrated that the main structure of the natatorium in its present status is safe and it still satisfies the demand of the national codes in China. But the roof system such as purlines and skeletons must be removed and rebuilt completely. Moreover the system identification results showed that field vibration test is sufficient to identify the reliable dynamic properties of the natatorium. The constructive suggestion on structural evaluation of the natatorium is that periodic assessment work must be maintained to ensure the natatorium's safety in the future.

A Study on Strength Evaluation of Adhesive Joints(1st Report, Stress Analysis and Fracture Strength of Adhesive Single-Lap Joint) (접착이음의 강도평가에 관한 연구 (제1보 겹치기 접착이음의 응력해석과 파괴강도))

  • 정남용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.667-674
    • /
    • 1992
  • Recently advantages in composite and light weight material technique have led to the increased use of structural adhesives in various industries. In spite of such wide application of the adhesive joints, the evaluation method of fracture strength and design methodology of them, have not been established. In this study finite element method, theoretical and experimental analyses were investigated according to changes of lap length and adhesive for adhesive single-lap joint. As the results, the strength evaluation of adhesive joint by conventional nominal stress, was pointed out inadequate strength evaluation and design method regardless stress singularity, stress distribution and crack propagation in its adhesive layer. Also, it was examined the problems to apply fracture mechanics by means of static and fatigue test.