• Title/Summary/Keyword: Strong floor

Search Result 126, Processing Time 0.028 seconds

Performance Analysis of GFSK Systems by Impulsive Electromagnetic Noise in Indoor Radio Fading Channel Environment (실내 무선 페이딩 채널 환경에서 임펄스성 전자간섭파에 의한 GFSK시스템의 성능 분석)

  • 이양선;김지웅;강희조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1115-1121
    • /
    • 2001
  • In this paper, we analyzed the performance of GFSK system that presence fading effect in indoor radio communication environments and impulsive electromagnetic noise from electronic equipments then we applied the Truncated Type- II Hybrid ARQ scheme to make satisfied in data transmission service. As a result, the system was influenced by fading and impulsive electromagnetic noise. Especially, the system was much degraded by high occurrence frequency and amplitude of impulsive electromagnetic noise than fading which has direct frequency. By adopting the Truncated Type-II hybrid ARQ technique we can also obtained the performance improvement in the low signal power(20 dB) arid over 24 dB in strong impulsive electromagnetic noise environment which is occurred error floor and terribly influenced by the system.

  • PDF

Comparative histomorphologic study of regenerated bone for dental implant placement in the atrophied posterior maxilla

  • Kim, Se-Jung;Kim, Soung-Min;Kim, Ji-Hyuck;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.1
    • /
    • pp.28-39
    • /
    • 2007
  • The purpose of this study is to evaluate the regenerative capacity of reconstruction in the atrophied posterior maxilla by comparing bone graft procedures and alveolar distraction osteogenesis (ADO) techniques. We performed the autogenous iliac bone graft (AGB group, 5 specimens in 3 patients), and the combination (Mixed group, 3 specimens in 3 patients) of the autogenous and deproteinized bovine bone ($Bio-Oss^{(R)}$, Geistlich Co., Switzerland) as the ratio of 2:1 in the sinus floor elevation procedures. ADO procedures using $TRACK^{(R)}$ (KLS Martin Co., Germany) were also performed to augment vertical alveolar height in atrophied posterior maxilla (ADO group, 5 specimens in 4 patients). Newly generated bone tissues were obtained with the 2.0mm diameter trephine bur (3i Co., USA) during implant fixture installation after 5-7 months. Routine histolomorphological observation, immunodot blot assay for quantitative evaluation, and immunohistochemical staining with antibodies to MMP-1, -9, -10, TIMP-1, -2, and BMP-2, -4 were all carried out. Lamellar bone formation was well shown in all specimens and new bone formations of ADO group increased than those of other procedures. In immunohistochemical staining, the strong expression of BMP-2 was shown in all specimens, and immunodot blot assay showed that bone formation is accompanied by the good induction of factors associated with angiogenesis and appeared more increased amount of osteogenic and angiogenic factors in ADO group. ADO is the most effective technique for new bone formation compared to sinus floor elevation with autogenous or mixed bone graft in the atrophied posterior maxilla. In the quantitative immunodot blot assay, the regenerated bone after ADO showed more increased products of VEGF, BMP-2, PCNA and MMP-1 than those after the other procedures, and these findings were able to be confirmed by immunohistochemical stainings.

Improvement of Total Floor Area Planning for the Feasibility Study on the Establishment of a General Hospital - Focused on Pre-feasibility Study of KDI Case Analysis (종합병원 건립 타당성 조사의 연면적 계획 개선방안 - 공공의료기관 재정사업 예비타당성조사 사례를 중심으로)

  • Cho, Junyoung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.1
    • /
    • pp.37-44
    • /
    • 2024
  • Purpose: The planning of medical facilities involves formulating a comprehensive medical basic plan, translating it into spatial dimensions through a space program. Feasibility assessment often relies on empirical methods like floor area per bed. However, with the shift towards specialized medical concepts, proportional scaling to bed numbers is challenging. This study proposes scale planning improvements during the feasibility assessment stage for comprehensive hospitals, analyzing cases using area determination factors and standard areas based on medical resources. Methods: The Korean Development Institute's Public Investment Management Center (KDI) identified issues in the scale determination of medical facilities in the Preliminary Feasibility Study Guidelines and investigated alternative approaches for determining the scale of a case that passed the preliminary feasibility study in 2019. The study assessed the feasibility of applying individual factors to determine not only the number of beds but also the scale at the sector and department levels. Additionally, a statistical analysis was conducted to examine the correlation between the total number of beds and various area determination factors. Results: Results suggest a strong correlation between total beds and major equipment needs, but in hospitals with <500 beds, this correlation weakens. Ward section scale is better calculated per ward type, not just total beds. Outpatient department scale depends on specialists, influencing treatment room numbers. Medical personnel play a crucial role in determining the scale of sections like rehabilitation therapy rooms, operating rooms, dialysis rooms, and overall facility scale.

Relationship Between the Closed Kinetic Chain Upper Extremity Stability Test and Strength of Serratus Anterior and Triceps Brachii Muscles

  • Weon, Young-soo;Ahn, Sun-hee;Kim, Jun-hee;Gwak, Gyeong-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.208-214
    • /
    • 2021
  • Background: The CKCUES test evaluates the functional performance of the shoulder joint. The CKCUES test scores CKC exercises of the upper limbs to examine shoulder stability. Although the CKCUES test provides quantitative data on functional ability and performance, no study has determined the relationship between CKCUES scores and SA and TB muscle strength. Objects: The objective of this study is to determine the relationship between the CKCUES test scores and the strength of the SA and TB muscles in the CKCUES and unilateral CKCUES tests. Methods: Sixty-six healthy male volunteers participated in the study. A Smart KEMA strength sensor measured SA and TB muscle strength. Two parallel lines on the floor indicated the initial hand placement to start CKCUES tests. For 15 seconds, the subject raises one hand and reaches over to touch the supporting hand, then returns to the starting position. Results: The correlation between the CKCUES test scores and the strength of the SA was strong (r = 0.650, p < 0.001), and the TB was moderate (r = 0.438, p < 0.001). The correlation between the unilateral CKCUES test and the strength of the SA of the supporting side was strong (r = 0.605, p < 0.001), and swing side was strong (r = 0.681, p < 0.001). The correlation between the unilateral CKCUES test and the strength of the TB of the supporting side was moderate (r = 0.409, p < 0.001), and swing side was moderate (r = 0.482, p < 0.001). Conclusion: Our study showed that the CKCUES test had a strong association with isometric strength of SA and moderate association with that of TB. These findings suggest that the CKCUES test can evaluate the function of the SA. Moreover, the unilateral CKCUES test can evaluate unilateral shoulder function.

Structural Design and Performance Evaluation of a Mid-story Seismic Isolated High-Rise Building

  • Tamari, Masatoshi;Yoshihara, Tadashi;Miyashita, Masato;Ariyama, Nobuyuki;Nonoyama, Masataka
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.227-235
    • /
    • 2017
  • This paper describes some of the challenges for structural design of a mid-story seismic isolated high-rise building, which is located near Tokyo station, completed in 2015. The building is a mixed-use complex and encompasses three volumes: one substructure including basement and lower floors, and a pair of seismic isolated superstructures on the substructure. One is a 136.5m high Main Tower (office use), and the other is a 98.5 m high South Tower (hotel use). The seismic isolation systems are arranged in the $3^{rd}$ floor of the Main Tower and $5^{th}$ floor of the South Tower, so that we call this isolation system as the mid-story seismic isolation. The primary goal of the structural design of this building was to secure high seismic safety against the largest earthquake expected in Tokyo. We adopted optimal seismic isolation equipment simulated by dynamic analysis to minimize building damage. On the other hand, wind-induced vibration of a seismic isolated high-rise building tends to be excited. To reduce the vibration, the following strategies were adopted respectively. In the Main Tower with a large wind receiving area, we adopted a mechanism that locks oil dampers at the isolation level during strong wind. In the South Tower, two tuned mass dampers (TMDs) are installed at the top of the building to control the vibration. In addition, our paper will also report the building performance evaluated for wind and seismic observation after completion of the building. In 2016, an earthquake of seismic intensity 3 (JMA scale) occurred twice in Tokyo. The acceleration reduction rate of the seismic isolation level due to these earthquakes was approximately 30 to 60%. These are also verified by dynamic analysis using observed acceleration data. Also, in April 2016, a strong wind exceeding the speed of 25m/s occurred in Tokyo. On the basis of the record at the strong wind, we confirmed that the locking mechanism of oil damper worked as designed.

A Study on the Traditional Houses of North Korea(II) - Based on the Memories of Immigrants from North Korea - (북한지역(北韓地域) 전통주거(傳統住居)에 관한 조사연구(調査硏究)(2) -북한출신주민들의 지식체계분석을 통하여-)

  • Kang, Young-Hwan
    • Journal of architectural history
    • /
    • v.6 no.3 s.13
    • /
    • pp.61-76
    • /
    • 1997
  • A study on the traditional houses of North Korea(I) have been published in 1996. This paper is written to supplement the preceding paper. This paper aims at collecting new data of traditional house in North Korea. But still being prohibited for the researchers of South Korea to approach to the field, I had to depend on the memories and experiences of the immigrants from North Korea who are now living in Kangwon and Incheon Province. Through the questionnaire and drawings, they described vivid memory of their old houses. I was able to add new data of 70 cases, which are significant and valuable as much as those of the real field are. Those data, including the exisiting data, are enough for me to analize statstically the regional charateristics, the differnces among economical classes, and the periodical change. It opens the way for verfying the existing theory. Regional charateristics of house in North Korea can be described as followings: a. Hamkyong-do ; Concentrating spaces into one building, Double-fold type plan, Including 'cheongju-kan' space, Weak fences b. Pyongan-do ; Concentrating spaces into two buildings, 二 shape buildings , Single-fold type plan, Strong fence c. Pyongannam-do to Myolak mountains; Concentraing spaces into two buildings, ㄱ, ㄷ shape buildings, Single-fold type plan, Strong fence d. Southern area of Myolak mountains; Concentrating spaces into one building ㅁ shape building, Single-fold type plan with wooden floor space

  • PDF

Base isolated RC building - performance evaluation and numerical model updating using recorded earthquake response

  • Nath, Rupam Jyoti;Deb, Sajal Kanti;Dutta, Anjan
    • Earthquakes and Structures
    • /
    • v.4 no.5
    • /
    • pp.471-487
    • /
    • 2013
  • Performance of a prototype base isolated building located at Indian Institute of Technology, Guwahati (IITG) has been studied here. Two numbers of three storeyed single bay RCC framed prototype buildings were constructed for experimental purpose at IITG, one supported on conventional isolated footings and the other on a seismic isolation system, consisting of lead plug bearings. Force balance accelerometers and a 12 channel strong motion recorder have been used for recording building response during seismic events. Floor responses from these buildings show amplification for the conventional building while 60 to 70% reduction has been observed for the isolated building. Numerical models of both the buildings have been created in SAP2000 Nonlinear. Infill walls have been modeled as compression struts and have been incorporated into the 3D models using Gap elements. System identification of the recorded data has been carried out using Parametric State Space Modeling (N4SID) and the numerical models have been updated accordingly. The study demonstrates the effectiveness of base isolation systems in controlling seismic response of isolated buildings thereby leading to increased levels of seismic protection. The numerical models calibrated by relatively low level of earthquake shaking provides the starting point for modeling the non-linear response of the building when subjected to strong shaking.

Effect of Floor Plan Characteristics on Housing Price - Focused on the Apartment in 3 Gangnam Districts since 2005 - (공동주택 평면특성의 가격영향에 관한 연구 - 강남3구의 2005년 이후 분양주택을 중심으로 -)

  • Bae, Sangyoung;Lee, Jaewon;Lee, Sangyoub
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.4
    • /
    • pp.102-110
    • /
    • 2018
  • The study analyzed the effects of the floor plan characteristics on the apartment price under the national housing size in 3 Gangnam districts for decades, the primary apartment markets in Korea. The analysis showed that the storage spaces such as kitchen, warehouses and dressage rooms have a positive effect on the price. Especially, the highly opened space with three-side open plan and the one with the unified type of livingroom, diningroom and kitchen have shown the strong effect on the price. For the kitchen spaces, the I-shaped kitchen tends to be more expensive while a centered living room has a positive effect on the price. These findings have an academic significance as the direct effects of plan characteristics on price has been examined unlike prior research focused on the analysis of trend, basic statistics, and satisfaction level. It is noteworthy that these research finding has identified the productive implication for the future floor plan design and pricing and also be implemented in the purchasing decision making by buyers in the housing market.

On estimation of the probability of Yut (윷의 확률 추정에 대하여)

  • 박진경;박승선
    • The Korean Journal of Applied Statistics
    • /
    • v.9 no.2
    • /
    • pp.83-94
    • /
    • 1996
  • The probability of Yut was calculated by using the physical property in previous study, but this article suggested empirical estimators for probability of Yut. In practice, physics-based probability imposes too strong assumptions, which result in the difference between the calculated probabilies and empirical relative frequencies. Experiment shows the probabilities of Yut depend on the integrated shape of Yut rather than the floor type. Maximum likelihood estimator and empirical Bayes estimators are compared and all turn out to be almost identicla for more than 40 trials. For smaller number of trials, Bayes estimators are recommended for its stability. Regression approach is also adopted as an easy-to-use method without empirical trials.

  • PDF

An analysis of ITI implants placed in korean patients (한국환자에 매식된 ITI 임플란트에 관한 조사)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.361-370
    • /
    • 2002
  • The aim of this study was to analyze various data of 120 non-submerged ITI implants placed in 64 korean adults. The data were retrieved from patients' charts and registered in the computer and coded for a statistical analysis. The results revealed that the most common type of edentulism was a distal extension case, and the largest number of implants were placed in the mandibular first molar position. Implants were placed more frequently in mandibular, posterior position than maxillary, anterior position, respectively. With respect to the implant diameter and length, an implant with 4.1mm in diameter and more than 10mm in length was the most common. Since a molar position was the most prevalent position for implant placement in korean patients, clinicians should be careful about implant diameter which can resist a strong occlusal force expected in the molar position. In addition, the distance to the mandibular canal and the floor of maxillary sinus should be considered to avoid possible damages, such as nerve injury and sinus perforation in selecting a proper implant length.