Abstract
Performance of a prototype base isolated building located at Indian Institute of Technology, Guwahati (IITG) has been studied here. Two numbers of three storeyed single bay RCC framed prototype buildings were constructed for experimental purpose at IITG, one supported on conventional isolated footings and the other on a seismic isolation system, consisting of lead plug bearings. Force balance accelerometers and a 12 channel strong motion recorder have been used for recording building response during seismic events. Floor responses from these buildings show amplification for the conventional building while 60 to 70% reduction has been observed for the isolated building. Numerical models of both the buildings have been created in SAP2000 Nonlinear. Infill walls have been modeled as compression struts and have been incorporated into the 3D models using Gap elements. System identification of the recorded data has been carried out using Parametric State Space Modeling (N4SID) and the numerical models have been updated accordingly. The study demonstrates the effectiveness of base isolation systems in controlling seismic response of isolated buildings thereby leading to increased levels of seismic protection. The numerical models calibrated by relatively low level of earthquake shaking provides the starting point for modeling the non-linear response of the building when subjected to strong shaking.
Keywords
base isolation; lead rubber bearings; numerical models; system identification; N4SID;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Wen, Y.K. (1976), "Method for random vibration of hysteretic systems", J. Eng. Mech. Div.-ASCE, 102(EM2), 249-263.
2 Wu, Y.M. and Samali, B. (2002), "Shake table testing of a base isolated model", Eng. Struct., 24(9), 1203-1215.   DOI   ScienceOn
3 Skinner, R.I., Robinson, W.H. and McVerry, G.H. (1991), "Seismic isolation in New Zealand", Nucl. Eng. Des., 127(3), 281-289.   DOI   ScienceOn
4 Nagarajaiah, S. and Xiaohong, S. (2000), "Response of base-isolated USC hospital building in Northridge earthquake", J. Struct. Eng.-ASCE, 126(10), 1177-1186.   DOI   ScienceOn
5 Overschee, P.V. and Moor, B.D. (1993), "N4SID: Numerical algorithms for state space system identification", Proceedings of the World Congress of the International Federation of Automatic Control, IFAC, Sydney, Australia.
6 Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), "Random vibration of hysteretic systems under bi-directional ground motions", Earthq. Eng. Struct. D., 14(4), 543-557.   DOI
7 Providakis, C.P. (2008), "Pushover analysis of base-isolated steel-concrete composite structures under near-fault excitations", Soil. Dyn. Earthq. Eng., 28(4), 293-304.   DOI   ScienceOn
8 Providakis, C.P. (2008), "Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations", Eng. Struct., 30(5), 1187-1198.   DOI   ScienceOn
9 Moroni, M.O., Sarrazin, M. and Boroschek, R. (1998), "Experiments on a base-isolated building in Santiago, Chile", Eng. Struct., 20(8), 720-725.   DOI   ScienceOn
10 Naeim, F. and Kelly, J.M. (1999), Design of seismic isolated structures: From theory to practice, John Wiley & Sons, Inc., New York.
11 Computers and Structures Inc. (2009), CSI analysis reference manual for SAP2000(R), ETABS(R), and SAFE(R), Reference manual, Computers and Structures Inc., Version 14, Berkeley, California, USA.
12 Dubey, P.N., Reddy, G.R., Deb, S.K., Vaze, K.K., Ghosh, A.K. and Kushwaha, H.S. (2007), "Performance of base isolated RCC framed building under actual earthquake", Proceedings of 1st Intl. Conf. on Earthquake Hazards and Management, Guwahati, India.
13 Jain, S.K. and Murty, C.V.R. (2006), Proposed draft provisions and commentary on ductile detailing of RC structures subjected to seismic forces, Document no, IITK-GSMDA-EQ11-V-3.0, IITK-GSMDA-EQ16-V-2.0.
14 Borsaikia, A. Ch., Dutta, A. and Deb, S.K. (2011), "System identification of multi-storeyed non standard shear building using parametric state space modeling", Struct. Control Health., 18(4), 471-480.   DOI   ScienceOn
15 Braga, F. and Laterza, M. (2004), "Field testing of low-rise base isolated building", Eng. Struct., 26(11), 1599-1610.   DOI   ScienceOn
16 Jangid, R.S. (2007), "Optimum lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29(10), 2503-2513.   DOI   ScienceOn
17 Jangid, R.S. and Kelly, J.M. (2001), "Base isolation for near-fault motions", Earthq. Eng. Struct. D., 30(5), 691-707.   DOI   ScienceOn
18 Kaushik, H.B., Rai, D.C. and Jain, S.K. (2007), "Stress-strain characteristics of clay brick masonry under uniaxial compression", J. Mater. Civil Eng., 19(9), 728-739.   DOI   ScienceOn
19 Matsagar, V.A. and Jangid, R.S. (2004), "Influence of isolator characteristics on the response of base-isolated structures", Eng. Struct., 26(12), 1735-1749.   DOI   ScienceOn
20 Medhi, M., Dutta, A. and Deb, S.K. (2007), "Health monitoring of multi storeyed shear building using parametric state space modeling", Smart. Struct. Syst., 4(1), 47-66.