• Title/Summary/Keyword: Strip-type sensor

Search Result 20, Processing Time 0.027 seconds

Development of Eco-friendly Paper Glucose Sensor Using Printing Technology (인쇄 기술을 이용한 친환경 종이 혈당 센서 스트립 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.116-120
    • /
    • 2020
  • In this paper, we developed an electrochemical glucose sensor strip using a paper substrate. The paper glucose sensor strip is eco-friendly because it uses paper as a substrate, and it has the advantage that it can be manufactured only with four printing, drying and cutting processes. The paper glucose sensor is significantly simplified by the production process than the conventional glucose sensors because the production of only four printing on the paper substrate. In this paper, eco-friendly tracing paper was used to develop a paper glucose sensor strip, and screen-printing technology was used to form a carbon/silver electrode, insulating layer and glucose oxidase(GOD) layer. The developed paper glucose sensor strip has a flat structure with a size of 30 × 4.6 ㎟, and blood injection is a type of direct contact with the exposed enzyme layer above the strip. In this paper, the performance of paper glucose sensor strips was evaluated by analyzing the cyclic voltammetry(CV) and chronoamperometry(CA) characteristics.

Self Sensing Reinforcement Combined with Fiber-Optic Sensor and FRP Strip for Structural Reinforcement (구조물 보강용 FRP 판과 광섬유 센서가 결합된 자기감지 보강재)

  • Song, Se-Gi;Seo, Soo-Yeon;Kim, Kang Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.123-130
    • /
    • 2019
  • Recently, it is required to develop a monitoring technology that combines an FBG sensor as a means for continuously monitoring whether reinforcing effect of FRP is maintained on FRP reinforced structural members. However, most existing researches focus on the insertion of FBG sensors into bar-shaped FRPs, and there is insufficient study on the details strip-type FRPs combined with FBG sensors. Therefore, in this paper, it is studied to develop a reinforcement in which a FBG sensor is combined with a FRP strip. Especially, combination of FRP and FBG sensor. For this, a series of experiments were performed to find the adhesive strength of fiber-FRP-epoxy joints, the tensile strength of FBG sensor part with reflection-lattice, and the performance depending on the connection method of FRF and FBG sensor. As a result of the study, it was found that a minimum strength of $216.15N/mm^2$ is required for incorporating FBG sensors in FRP using epoxy. It is considered that the adhesion length of epoxy joints should be more than 50mm. When the FBG sensor is attached to the FRP strip as an epoxy, it is considered appropriate to use the complete attachment and the sensor non-attachment method.

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Development of a Contact Type Temperature Sensor Using Single Crystal Silicon Thermopile (단결정 실리콘 써모파일을 이용한 접촉형 온도센서 개발)

  • Lee, Young-Tae;Lee, You-Na;Lee, Wang-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.369-373
    • /
    • 2013
  • In this paper, we developed contact type temperature sensor with single crystal silicon strip thermopile. This sensor consists of 15 p-type single crystal silicon strips, 17 n-types and contact electrodes on silicon dioxide silicon membrane. The result of electromotive force measuring showed very good characteristic as $15.18mV/^{\circ}C$ when temperature difference between the two ends of the thermopile occurs by applying thermal contact on the thermopile which was fabricated with silicon strip of $200{\mu}m$ length, $20{\mu}m$ width, $1{\mu}m$ thickness.

Development of Disposable Enzyme-linked Immunosensor Strip Platform (일회용 스트립형 효소면역센서용 플랫폼의 개발)

  • Choi, Ji-Hye;Yi, Seung-Jae;Chang, Seung-Cheol;Kim, Kyung-Chun
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.400-405
    • /
    • 2011
  • This study introduced the development of a strip type disposable enzyme-linked immunosensor platform for the detection of IgG. Strips of the strip sensor were fabricated by using commercial nitrocellulose filter membranes and a housing holder for the strips was manufactured by using a standard injection molding process for a plastic material. An IgG-urease conjugate was prepared and used for the competitive immune-binding with sample IgG. From the enzymatic reaction between the conjugated urease and urea added, ammonia was generated and caused a localized alkaline pH change on the immobilized antibody band which was coated onto the sensor strips. This pH increase subsequently caused a color change of the antibody band in the presence of a pH indicator, phenol red. Used in conjunction with a competitive immunoassay format, the intensity of the color produced is directly linked with the concentration of target analyte, IgG, and specific measurement of IgG in a lateral flow immunoassay format was achieved over the range 100 ppb to 2000 ppb IgG.

Disposable Strip-type Sensors for Detection of Free Chlorine (유리염소 측정을 위한 일회용 스트립 센서)

  • Kim, Seung Ki;Kang, Tae Young;Cha, Geun Sig;Nam, Hakhyun;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.242-248
    • /
    • 2012
  • The measurement of residual chlorine as a disinfectant is very important to ensure the safety against the pathogenic microbes and to suppress injection. The portable free chlorine sensor was fabricated with a disposable strip format by a screen printing method. The strip sensors prepared with a carbon-Ag/AgCl(cathode-anode) combination exhibited less interfering responses towards combined chlorine species(especially $NHCl_2$) and oxygen than the sensors prepared with other metals(i.e., gold and platinum). Free chlorine was determined chronoamperometrically with carbon-based electrodes at an applied potential of -0.3 V(vs. Ag/AgCl). A channel was built on the strip-type electrode for easy sampling, and the resulting strip sensors were employed to determine the concentrations of residual free chlorine.

Disposable Glucose Sensor Based on Platinised Carbon Paste Electrode (백금 도금된 탄소반죽 전극을 이용한 일회용 글루코오스 센서)

  • Lee Dong Joo;Yoo Jae Hyun;Cui Gang;Choi Moon Hee;Kim Moon Hwan;Ryu Joon Oh;Han Sang-Hyun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.227-231
    • /
    • 1999
  • Disposable, amperometric glucose sensor was constructed using platinised carbon paste electrode. The sensor response was studied by amperometry and cyclic voltammetry applying sample solutions on the strip-type electrode. Platinization of screen-printed carbon paste electrode effectively improved the electrochemical reversibility of a mediator and the analytical characteristics of the sensor. The heterogeneous rate constant for $[Fe(CN)_6]^{4-/3-}$ was $1.45\times10^{-2}cm{\cdot}s^{-1}$. An applied potential of 0.3V vs. Ag/AgCl resulted in the best selectivity for glucose. The apparent Michaelis-Menten constant for glucose on the strip sensor, $K_m^{app}$, was 24.5 mM. To evaluate the analytical performance of the glucose sensor strip, a correlation study was performed with the NOVA S.P, Ultra M analyzer for 30 serum samples containing $80\~297mg/dL$ of glucose: the correlation coefficient value was 0.983. It can be seen that the strip sensor has satisfactory precision and accuracy.

A Strip Sensor Based on PbO2/Carbon Paste Electrode to Determine Sweetener Contents in Fruits (이산화납/탄소 반죽 전극을 이용한 과당 농도 측정 스트립센서)

  • Lee, Jae Seon;Cho, Joo Young;Heo, Min;Lim, Woo-Jin;Lee, Sang Eun;Nam, Hakhyun;Cha, Geun Sig;Shin, Jae Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.2
    • /
    • pp.130-137
    • /
    • 2014
  • A strip sensor based on $PbO_2$/carbon paste electrode was prepared by a screen-printing method, and employed to electrochemically determine the concentration of fruit sweeteners(i.e. glucose, sucrose, and fructose). The $PbO_2$/carbon paste electrode could monitor electrocatalytic oxidation of organic compounds such as carbohydrates, and measure the levels of natural sweeteners without enzyme. Severe interference from ascorbic acid was effectively reduced by modifying the electrode surface with a Nafion membrane. The response level of the Nafion/$PbO_2$/carbon paste electrode increased in the order of fructose, sucrose, and glucose, which corresponds to the order of sweetness perceived by humans.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Off-Line PD Diagnosis for Stator Winding of Rotating Machines Using a UWB Sensor

  • Lwin, Kyaw-Soe;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.263-270
    • /
    • 2008
  • We studied partial discharge detection by sensing electromagnetic waves emitted from the partial discharge source in an HV Rotating Machine using a UWB sensor. In this study, we design a new type of compact low frequency UWB sensor based on micro-strip technology. We also perform many experiments of offline and dismantled testing compared with the existing HFCT on stator winding of the HV generator. We mention the detailed design of a new compact UWB sensor along with the time domain PRPD pattern and frequency domain results of partial discharge in the stator winding of a 6.6kV rotating machine by offline testing performed in a laboratory.