• Title/Summary/Keyword: Stress measurement method

Search Result 636, Processing Time 0.024 seconds

Influence of the Inclined Hole in Residual Stresses Measurement Using the Hole-Drilling Method (구멍뚫기법을 이용한 잔류응력 측정시 경사구멍의 영향)

  • Kim, Cheol;Yang, Won-Ho;Seok, Chang-Sung;Heo, Sung-Pil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.201-206
    • /
    • 2001
  • The hole-drilling method makes a little hole through the metal surface that has residual stress and measures the relieved stress with a strain gage. It is used widely in measuring the residual stress of surfaces. In this method, the inclined hole is one of the source of error. This paper presents a finite element analysis of influence of the inclined hole for the uniaxial residual stress field. The stress differences between measured and applied residual stress increase proportionally to inclined angle of the hole. The correction equations which easily obtain the residual stress taking account of the inclined angle and direction are derived. The measurement error of stress due to the inclined hole can be reduced to around 1% through this study.

  • PDF

Determination of Residual Stress by the Hole Drilling Method Based on Displacement Measurement (변위 측정을 기본으로 한 구멍뚫기방법에 의한 잔류응력 측정 방법)

  • Shin, Dong Il;Joo, Jin Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.11 s.242
    • /
    • pp.1542-1550
    • /
    • 2005
  • This paper presents the numerical procedure for calculating non-uniform residual stresses based on relieved displacements obtained from incremental hole drilling. The relationship between the in-plane displacement produced by introducing a blind hole and the corresponding residual stress is established. Finite element calculations are described to evaluate the relieved coefficients required for the determination of non-uniform residual stresses. Validity of the proposed method has been tested through three axisymmetric test examples and two three-dimensional examples. As a result of . simulation on the test examples, it is found that this numerical procedure is well adopted to measuring non-uniform residual stress in the full hole depth range of the hole diameter from the surface. The accuracy of the hole drilling method with displacement measurement is discussed, comparing tile method with strain measurement

Estimation of Residual Stresses in Micromachined Films (마이크로머시닝 기술에 의해 형성된 막에 있어서의 잔류응력 추정)

  • Min, Yeong-Hun;Kim, Yong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.6
    • /
    • pp.354-359
    • /
    • 2000
  • A new method of measuring residual stress in micromachined film is proposed. An estimation of residual stress is performed by using least squares fit with an appropriate deflection modeling. an exact value of residual stress is obtained without any of the ambiguities that exist in conventional buckling method, and a good approximation is also obtained by using a few data points. Therefore, the test structures area could be greatly decreased by using this method. The measurement can be done more easily and simply without any actuation or any specific measuring equipment. The structure and fabrication processes described in this paper are simple and widely used in surface micromachining. In addition, in-situ measurement is available by using the proposed method when the test structure and the measurement structure are fabricated on a wafer simultaneously.

  • PDF

Development of Rock Stress Measurement Probe Based on The Pilot Hole Wall Deformation Method (Pilot 공벽변형법에 의한 암반응력 측정 장비의 개발)

  • Lee, Ki-Ha;Ishijima, Yoji;Koo, Ho-Bon;Kim, Seung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1125-1132
    • /
    • 2009
  • The theory and a probe of the pilot hole wall deformation method, which is a 3-dimensional stress measurement method based on the stress relief principle, were developed. A pilot hole is drilled from the bottom of a borehole and the stress measurement probe is inserted into the pilot hole. The borehole is advanced as the overcoring and the changes in the radius of the pilot hole in three directions and in the axial lengths between the borehole bottom and the pilot hole wall along four axial lines are measured by cantilever type-displacement sensors. The differences between the displacements by the elastic stress analysis and those measured by using the probe were within 3% in the uniaxial compression test of an acrylic resin plate having a hole.

  • PDF

Numerical Study for Tunnel Shotcrete Lining Operated Stress Measurement Techique Development During a Construction (시공중 터널 숏크리트 라이닝 작용응력 측정기법 개발을 위한 수치해석적 연구)

  • Shin, Hyu-Seong;Kim, Dong-Gyou;Jung, Yong-Su;Hwang, Jae-Hong;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.754-761
    • /
    • 2008
  • In general, stress measurement of existent shotcrete lining be used by pressure cells. but, measuring instrument is lost by high pressure at shotcrete lining construction and pressure cell's measurement value have to low believability by natural conditions like curing temperature. In this study, proposed techniques to measure without utilizing sensitive stress sensor in natural condition at point that want stress of shotcrete lining after shotcrete lining construction. Executed numerical analysis to forecast stress level that interact in tunnel shotcrete lining, measured strain of hole by load action through hole in shotcrete lining. 3D FEM(finite element method) is enforced through various parameters curing time of shotcrete lining, thickness, load condition. Different model cases applied by parametic study. As analysis result, it could grasp development possibility of method that propose this time because it could examine corelation with strain by near hole of shotcrete lining and stress about load condition.

  • PDF

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

Stress Measurement of films using surface micromachined test structures (표면 미세 가공된 구조체를 이용한 박막의 응력 측정)

  • 이창승;정회환;노광수;이종현;유형준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.721-725
    • /
    • 1996
  • The microfabricated test structures were used in order to evaluate the stress characteristics in films. The test structures were fabricated using surface micromachining technique, including HF vapor phase etching as an effective release method. The fabricated structures were micro strain gauge, cantilever-type vernier gauge and bridge for stress measurement, and cantilever for stress gradient measurement. The strain was measures by observing the deformation of the structures occurred after release etching and the amount of deformation can be detected by micro vernier gauge, which has gauge resolution of 0.2${\mu}{\textrm}{m}$. The detection principles and the degree of precision for the measured strain were also discussed. The characteristics of residual stress in LPCVD polysilicon films were studied using these test structures. The stress gradient due to the stress variation through the film thickness was calculated by measuring the deflection at the cantilever free end.

  • PDF

FEM Analysis of Plasticity-induced Error on Measurement of Welding Residual Stress by the Contour Method

  • Shin, Shang-Hyon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1885-1890
    • /
    • 2005
  • The contour method relies on deformations that occur when a residually stressed component is cut along a plane. The method is based on the elastic superposition principle. When plasticity is involved in the relaxation process, stress error in the resulting measurement of residual stress would be caused. During the cutting the specimen is constrained at a location along the cut so that deformations are restrained as much as possible during cutting. With proper selection of the constraining location the plasticity effect can also be minimized. Typical patterns of longitudinal welding residual stress state were taken to assess the plasticity effect along with constraining locations.

Development of Measurement Equipment of Membrane Stress Using White Noise Sound Wave (화이트 노이즈 음파를 이용한 막구조물의 장력 측정장치 개발)

  • Jin, Sang-Wook;Ohmori, Hiroshi;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.63-72
    • /
    • 2008
  • One of the most important matters in keeping membrane structures in healthy condition is to maintain the proper tension distribution over the membrane. However, it is not easy to know the real stress level in the membrane quantitatively after completion of the structures. Authors suggested measurement method that can measure membrane stress using sound wave, and have been holding experimental tests of membrane stress measurement that used the sound external excitation with sine wave and white noise. The concept of the method is the fact that measurement of resonance frequency by vibrating membrane having rectangular boundary by audible frequency can measure membrane stress indirectly. In this paper, through the experimental tests it is proved that the equipment can be used for not only the membrane material of type A but also for types B and C. In addition, it is proved that the developed measurement equipment is available to stably measure the membrane stress which exists in the membrane material of the actual membrane structures.

  • PDF

Effect of Wall Groove Characteristics on Yield Stress Measurement of Magnetorheological Fluid

  • Tian, Zuzhi;Guo, Chuwen;Chen, Fei;Wu, Xiangfan
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.281-285
    • /
    • 2017
  • To suppress the wall slip effect and improve the yield stress measurement precision of magnetorheological fluid, measurement disks with different grooves are first manufactured. Then, the influence of groove characteristics on the yield stress of magnetorheological fluid is investigated by the method of experiments. Finally, the optimization wall grooves of measurement disks are obtained, and the yield stress of a self-prepared magnetorheological fluid is measured. Results indicate that the groove type and groove width have a slight influence on the shear yield stress, whereas the measured yield stress increases with enhanced groove density, and the optimized groove depth is 0.3 mm. The measured shear yield stress of self-prepared MR fluid can be improved by 18 % according to the optimized grooved disks, and the maximum yield stress can reach up to 65 kPa as the magnetic flux density is 0.5 T.