• Title/Summary/Keyword: Strength test

Search Result 13,651, Processing Time 0.039 seconds

Experimental study on strength anisotrophy of basalt in Cheju usland (제주도 현무암의 강도이방성에 대한 실험적 연구)

  • Song, Young-Suk;Nam, Jung-Mann;Yun, Jung-Mann
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1057-1062
    • /
    • 2008
  • In order to investigate a strength anisotrophy of basalt in Cheju Island, rock samples of Pyosenri basalt, trachy-basalt and scoria were taken from Seoguipo-Si Seongsan-Eup area, and a series of uniaxial compressive strength test and Brazilian test were carried out. The strengths were decreased with increasing the moisture contents in rock sample by pore water. As the result of test considering the anisotropy of rock strength, the compressive strength in condition of failure occurred parallel to stratified layer is decreased about 12-26% more than that in condition of failure occurred inclined to stratified layer.

  • PDF

Evaluation of Bond Performance for AC overlay on PCC Pavement (AC / PCC 복합포장 경계면 재료의 부착 성능 평가)

  • Kim, Dong kyu;Hwang, Hyun sik;Christopher, Jabonero;Ryu, Sung woo;Cho, Yoon ho
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.1-9
    • /
    • 2016
  • PURPOSES : This study focuses on the evaluation of interface performance with varying surface texture and tack coat application in an asphalt overlay. METHODS : The evaluation is carried out in two phases: tracking test and interface bond strength test. Using an image processing tool, tracking test is conducted to evaluate the susceptibility of the tack coat material to produce excessive tracking during application. Using the pull-off test method, the bond strength test is performed to determine the ability of the interface layer to resist failure. RESULTS : Results show that the underseal application yields less tracking compared to other applications. However, the bond strength is barely within the minimum acceptable value. On the other hand, RSC-4 produces higher bond strength for all surface types, but the drying time is long, which produces excessive tracking. CONCLUSIONS : While underseal application may be suitable for a trackless condition, the bond strength is less appealing compared to the rest of the tack applications available. RSC-4 demonstrated a high and consistent bond strength performance, but more time is required for drying to avoid excessive tracking. Tack coat application and surface type combination produce varying results. Therefore, these should be considered when selecting suitable future tack coat application options.

A Study of Axial Eccentricity Strength of High Strength Concrete Thin Walls for Internet of Things (사물인터넷 구현을 위한 고강도 콘크리트 박막벽체의 극한 편심하중 강도에 관한 연구)

  • Oh, Soontaek;Lee, Dongjun;Kim, Yeonsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • Recently, a high strength concrete(HSC) in excess of 80 MPa is popular to use in the domestic construction field. But there is no design standard of high strength concrete. It is reason why a study about structural behaviors of thin walls is required. In this paper, the accurate Finite Element Method as a virtual test is suggested considering material properties, which are concrete and steel, and the experimental fractural model suggested by Kupfer. It is conducted the comparison evaluation of the ultimate failure loads, lateral-displacements and crack propagation patterns between the results of experimental approach, which were carried on Saheb's test for normal strength concrete and Lee's test for high strength concrete. Therefore it is suggested to use the accurate virtual simulation test method and Ubiquitous Sensor Network(USN) by Finite Element Method for Internet of Things(IoT).

A Study Using Rebound Method and Impact Echo Method for the Comparison of the Compressive Strength of Concrete Slab (반발 경도법 및 충격반향기법을 이용한 콘크리트 슬래브의 압축강도 비교에 관한 연구)

  • Hong, Seong-Uk;Cho, Young-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.199-207
    • /
    • 2008
  • As infrastructures are being deteriorated, nondestructive evaluation of existing structures and construction quality control are increasingly demanded. The importance of predicting compressive strength of concrete structure is also gradually increasing in construction industry. The estimation of concrete compressive strength is a critical factor of the construction management and quality control. This study has been conducted using Schmidt hammer test and Impact echo method, which are nondestructive test methods for the comparison of the concrete compressive strength. It is focusing to examine the relationship between compressive strength of concrete and rebound number by Schmidt hammer test result by Impact echo method. It was found that concrete compressive strength and rebound number have a close correlation.

A Study on the Strength Prediction of Crushed Sand Concrete by Ultra-sonic Velocity Method (초음파속도법에 의한 부순모래 콘크리트의 강도 추정에 관한 연구)

  • Kim, Myung-Sik;Baek, Dong-Il;Youm, Chi-Sun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2007
  • Schmidt hammer and ultra-sonic method are commonly used for crushed sand concrete compressive strength test in a construction field. At present, various of equations for prediction of strength are present, which have been used in a construction field. The purpose of this study is to evaluate the correlation between prediction strength by presentation equations and destructive strength to test specimen, and find out which is a suitable equation for the construction site. In this study, a strength test was carried out destructive test by means of core sampling and traditional test. The experimental parameter were concrete age, curing condition, and strength level.

Comparison and Evaluation of Load Test Methods for Aluminum Car Body (알루미늄 차체 하중 시험 방법에 관한 비교 평가)

  • 서승일;박춘수;신병천
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.32-36
    • /
    • 2004
  • Aluminum carbody for rolling stocks is light and perfectly recycled, but includes severe defects which are very dangerous to fatigue strength. Static load test has been performed up to date to assess structural safety of the carbody. However, static load test is not sufficient to evaluate fatigue strength of the carbody, because fatigue failure is caused by dynamic load. In this study, the established load test methods for carbody are described and the characteristics of the methods are discussed. Also, a testing method to simulate dynamic loading condition is proposed for evaluation of fatigue strength of the carbody. The results by the proposed testing method are compared with the results by the static load test and new findings are discussed.

Non destructive test of fire-damaged high strength RC columns with polypropylene fiber (화재피해를 입은 PP섬유 혼입 고강도 콘크리트부재의 비파괴 검사)

  • Jung, Hye-Won;Choi, Eun-Gyu;Shin, Yeong-Soo;Lee, Cha-Don;Kwon, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.65-68
    • /
    • 2006
  • This study is aimed to investigate the strength variation of fire-damaged reinforced concrete column with polypropylene by non-destructive test. It is studied to infer the recovery degree of residual strength of fire-damaged concrete. For measuring the surface hardness of RC columns, Schmidt hammer test is used. Testing is performed four-times: before fire test, directly after fire test, after 30 days and after 4 months.

  • PDF

Shear Transfer Strength Evaluation for Ultra-High Performance Fiber Reinforced Concrete (강섬유 보강 초고성능 콘크리트의 전단 전달 모델)

  • Lee, Ji-Hyung;Hong, Sung-Gul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.69-77
    • /
    • 2015
  • Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.

Statistical division of compressive strength results on the aspect of concrete family concept

  • Jasiczak, Jozef;Kanoniczak, Marcin;Smaga, Lukasz
    • Computers and Concrete
    • /
    • v.14 no.2
    • /
    • pp.145-161
    • /
    • 2014
  • The article presents the statistical method of grouping the results of the compressive strength of concrete in continuous production. It describes the method of dividing the series of compressive strength results into batches of statistically stable strength parameters at specific time intervals, based on the standardized concept of "concrete family". The article presents the examples of calculations made for two series of concrete strength results, from which sets of decreased strength parameters were separated. When assessing the quality of concrete elements and concrete road surfaces, the principal issue is the control of the compressive strength parameters of concrete. Large quantities of concrete mix manufactured in a continuous way should be subject to continuous control. Standardized approach to assessing the concrete strength proves to be insufficient because it does not allow for the detection of subsets of the decreased strength results, which in turn makes it impossible to make adjustments to the concrete manufacturing process and to identify particular product or area on site with decreased concrete strength. In this article two independent methods of grouping the test results of concrete with statistically stable strength parameters were proposed, involving verification of statistical hypothesis based on statistical tests: Student's t-test and Mann - Whitney - U test.

Index Properties and Undrained Shear Strength of the Pusan Clays by Fall Cone Test (부산점토의 Fall Cone Test에 의한 지수 및 강도특성)

  • ;;Pham Huy Giao
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.391-398
    • /
    • 2000
  • The index properties of cohesive soils play an important role to examine entire tendency of soil properties. Especially, the Atterberg limits have a good correlation with compression and shear strength of cohesive soils. However, these values strongly depend on their testing methods. In this study, for Pusan clays the Atterberg limits were peformed under different conditions; for example, four kinds of specimen preparation, two kinds of testing equipment, and four kinds of estimating method. And a laboratory vane test was peformed to compare the undrained shear strength with that of the fall cone test. As experimental results, the value of liquid limit performed for oven-dried sample, followed in ASTM D4318, underestimated by about 10% compared to those of another three methods, irrespective to the used equipments. But the value of plastic limit was not influenced by sample preparation methods and equipments. The liquid limits by one-point methods(Leroueil et al., 1996; Nagaraj et al., 1981) were agreed well with those of different methods. Finally, the undrained shear strength by laboratory vane test was relatively larger than that of fall cone test, and the relationship between both showed a bad trend.

  • PDF