Experimental Study on Compressive Strength of Centrally Loaded Concrete Filled Square Tubular Steel Columns (중심축압(中心軸壓)을 받는 콘크리트충전(充塡) 각형강관(角形鋼管)기둥의 내력(耐力)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Jong Sung;Oh, Yun Tae;Kwon, Young Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.59-76
    • /
    • 1996
  • Concrete filled steel tube column has a large load carrying capacity through its steel and concrete interaction which makes it useful in construction. However, it has not been used often in a practical construction field. This is partly due to the non-destructive inspection method for concrete filling which has yet to be established. Furthermore, there are the lack of test data and a practical method in evaluating the ultimate load carrying capacity of concrete filled steel tube column. This paper will attempt to predict the ultimate strength of short concrete filled square tubular steel columns through conducting several tests. To accumulate the new test data on concrete filled steel tube columns, a total of 42 specimens of steel tubular columns were monotonically tested under concentric axial force, having the slenderness ratio(${\lambda}=10,\;15,\;20$), width-thickness ratio(d/t=25.0, 33.3) and concrete strengths($F_{c}=210,\;240,\;270kg/cm^{2}$). The hollow sections and concrete filled steel columns were compared to check the lateral confinded effects by steel tube. Through these test results, we propose a coefficient k=3.64 for the strength evaluation formula(10) of concrte filled tubular steel short columns.

  • PDF

Evaluation on Hysteretic Behaviors of V Shaped Metallic Dampers (V형 강재댐퍼의 이력특성 평가)

  • Lee, Hyun Ho;Kim, Seh Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.254-262
    • /
    • 2011
  • The purpose of this study is the development of V shaped metallic damper, which is superior than slit damper in energy dissipation capacity. For this purpose, 9 metallic damper specimens were prepared and shear testing were performed. According to test results, the V shaped metallic damper with strut height of 270mm and strut angle of $60^{\circ}$ shows a better seismic performance than any other specimens. The result of comparison with the yield strength of the dampers using the existing strength formula shows that V type metal dampers were highly evaluated than others within analyzing existing experimental result.

An artificial intelligence-based design model for circular CFST stub columns under axial load

  • Ipek, Suleyman;Erdogan, Aysegul;Guneyisi, Esra Mete
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.119-139
    • /
    • 2022
  • This paper aims to use the artificial intelligence approach to develop a new model for predicting the ultimate axial strength of the circular concrete-filled steel tubular (CFST) stub columns. For this, the results of 314 experimentally tested circular CFST stub columns were employed in the generation of the design model. Since the influence of the column diameter, steel tube thickness, concrete compressive strength, steel tube yield strength, and column length on the ultimate axial strengths of columns were investigated in these experimental studies, here, in the development of the design model, these variables were taken into account as input parameters. The model was developed using the backpropagation algorithm named Bayesian Regularization. The accuracy, reliability, and consistency of the developed model were evaluated statistically, and also the design formulae given in the codes (EC4, ACI, AS, AIJ, and AISC) and the previous empirical formulations proposed by other researchers were used for the validation and comparison purposes. Based on this evaluation, it can be expressed that the developed design model has a strong and reliable prediction performance with a considerably high coefficient of determination (R-squared) value of 0.9994 and a low average percent error of 4.61. Besides, the sensitivity of the developed model was also monitored in terms of dimensional properties of columns and mechanical characteristics of materials. As a consequence, it can be stated that for the design of the ultimate axial capacity of the circular CFST stub columns, a novel artificial intelligence-based design model with a good and robust prediction performance was proposed herein.

An Investigation into differences between codes for the Moment Strength of Deck Plates (데크플레이트의 휨 강도에 관한 기준 비교 연구)

  • Shin, Tae Song
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • This research aimed to experimentally and theoretically investigate the moment strength of deck plates. A moment experiment was carried out using a full-scale 14 specimen. To prevent local buckling, the point load was applied at 1/4 points. After the experiment, theoretical analysis was conducted and the differences between various codes were identified. The experimental results were compared with AISI (the American Iron and Steel Institute), EC (Euro Code) 3, and KS (Korea Standard) codes. Analysis results are summarized as follows: (1) the failure mode was influenced by local buckling at the midpoint of the beam and/or at the intermediate loading point: (2) if yielding first occurred at the tension side, the moment strength would increase as the plastic reservation of the tension zone acted: (3) the experimental results were closest to the EC3 codes in which the partial plastic reservation was considered; (4) statistical evaluation based on the EC3 Annex Z showed that the partial resistance safety coefficient calculated applying to the EC3 formula, $^{\circ}{_M}$, was placed within 1.1 which was the target value of EC3 code; and (5) the analytical power of AISI and KS codeswere expected to improve into the level of EC3 codes if the concept of plastic reservation of the tension side would be introduced to them.

Fatigue Life Evaluation of Welded Joints by a Strain-life Approach Using Hardness and Tensile Strength

  • Goo Byeong-Choon;Yang Seung-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.42-50
    • /
    • 2006
  • To evaluate the fatigue lifetime of structures, it is necessary to identify the values of parameters through tests. From the viewpoint of time and cost it is difficult for engineers to get the necessary data through tests. In this study, we surveyed literature and proposed a procedure to identify the fatigue parameters expressed with the Brinell hardness and elastic modulus. After obtaining stress concentration factors by finite element analysis, we calculated fatigue notch factors using Peterson's formula. Taking into account the welding residual stress, which was also obtained by finite element analysis, we evaluated the fatigue lifetime of four kinds of welded joints using the proposed approach. The estimated results are in a good agreement with the experimental results.

An Experimental Study on Size-effect for Characteristic of Flexural Strength of Pavement Concrete (포장 콘크리트의 크기 효과에 따른 휨 강도 특성 분석에 관한 실험적 연구)

  • Lee, Hyeongi;Oh, Hongseob;Sim, Jongsung;Sim, Jaewon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.299-306
    • /
    • 2015
  • The quality for the domestic pavement is evaluated based on flexural strength at the age of 28 days in accordance with KS regulation. Most specimens of the flexural tensile strength used currently are relatively large ones with a dimension of $150{\times}150{\times}550mm$. Accordingly, it is difficult to treat the specimens, and the utilization of a curing tank is low. In this paper, the study tried to resolve the problem by specimen size specified in the code. For this purpose, a flexural strength test was conducted according to the log scale within the specimen size specified by the KS. And, based on the results of this experiment, a comparative analysis was conducted using the prediction formula of Size Effect Law (SEL) proposed by Bazant to examine the correlation between specimen sizes, so as to use the result as basic data for the reduction of the specimen size in the quality evaluation of concrete pavement.

A Study on the Evaluation of Member Buckling Performance of Space Frame Structures (스페이스 프레임 구조물의 부재좌굴성능 평가방안 연구)

  • Kang, Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.176-182
    • /
    • 2018
  • The purpose of this study was to investigate the safety and rationality of buckling strength and length coefficient by comparing with the design standards of domestic and foreign compression materials based on the buckling test results of circular steel pipe with ball joints. The types of round steel pipes selected for buckling performance evaluation were ø$48.6{\times}2.8t$, ø$60.5{\times}3.2t$ and ø$76.3{\times}3.2t$. For the design of domestic and foreign compression materials, Korea 's Load Resistance and Factor Design, Japan' s Limit State Design, and British Standard BS5950 standard were applied. In this study, we compared and analyzed the buckling performance between the experimental results of the previous research and the domestic and foreign design standards. The results were summarized as follows. As a result of applying the full length of the member to the buckling length in the compression materials design standards of each country, it was 64-89% of the buckling strength by the experiment. Therefore, it is deemed desirable to perform the member design according to the current design standard formula for safety. Experimental results show that the measured buckling strength was 1.02-1.43 times higher than the buckling strength of pure cylindrical steel tubes in the design standards of Korea, Japan and the United Kingdom compression materials. Consequently, it seemed that the buckling strength of individual member in the design of space frame structure should be considered buckling coefficient as the length of pure round steel pipe rather than the length of inter-node.

Evaluation on the In-plane Bending Moment for T-joints with Square Hollow Structural Sections (각형강관 T형 접합부의 면내 휨모멘트 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Young Hwan;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.451-459
    • /
    • 2009
  • The purpose of this study was to evaluate the in-plane bending moment for T-joints made of cold-formed square hollow steel sections. In the previous studies, the T-joint was shown not to have an obvious peak load, and the failure mode was the main chord flange failure at the branch-width-to-chord-width ratio ($\beta$) of below 0.71. Based on the experimental results, including the tests conducted by Zhao, the deformation limit of 1% B was proposed for ${16.7{\leq}2{\gamma}(=B/T){\leq}33}$ and ${0.34{\leq}{\beta}(=b_{1}/B){\leq}0.71}$. Then, the ultimate in-plane bending strength was shown to be Mu=1.5${\cdot}$M1% B. The existing strength formulae for the original T-joint were investigated and were determined to be the main chord flange failure for the branch-squared T-joint. The bending strength formulae of CIDECT and other researchers were compared with the test results. Finally, a reasonably good agreement with Zhao's formula was found. Therefore, the design guidelines were presented based on Zhao's strength formula for T-joints.

Evaluation of Shear Strength by Experiment and Finite Element Analysis of SFRC Hollow Members (SFRC 중공 부재의 실험 및 유한요소 해석에 의한 전단강도 평가)

  • Kim, Seong-Eun;Jeong, Jae-Won;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.78-85
    • /
    • 2019
  • This study targets SFRC hollow members with small depth under shear force and bending. To evaluate the effect of web width on shear strength of SFRC members, experiment and finite element analysis were conducted and compared with existing equations. The web width was planned to be 1/2 times and 2/3 times, and the shear span ratio was planned to be 1.5 times. In the shear test results, the maximum shear strength increased by 10.3 to 28.0% with the web width increased by 33%. When the overall depth of specimens was increased by 1.5 times, the shear strength of the specimen with a web width of 100mm was increased by 29.2%. On the other hand, specimen with the 150mm only increased by 11.3%. These results indicate that the smaller the web width, the greater the shear strength increase with the increase of depth. Also, the smaller the web width, the greater the contribution of steel fiber. It has been shown that the KCI code evaluates the shear strength of experiments as very safe side, and that the proposed formula of Shin et al. predicts the experimental strength relatively well. As the web width increases by 2, 3, and 6 times, the mean shear strength by FEA appears to be 1.18, 1.80, and 2.19 times respectively. This indicates that the shear strength does not increase in proportion to the increase in web width.

Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections (지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.581-591
    • /
    • 2005
  • This paper proposes a design formulae that evaluates the design strength of T-joints made of cold-formed square hollow steel sections with longitudinal branch plate. The T-joints had a configuration that a branch member used to longitudinal plate to the main chord in the plane. This study focused on the branch plate T-joints governed by the main chord flange failure mode among the experimental results. Based on the test results of the longitudinal branch plate T-joint in the square hollow sections, the ultimate strength on the T-joints was defined as 1.5 times the load at 1% B the strength of joints that governed the serviceability in control for $16.7{\leq}2\gamma(B/T){\leq}31.3$ and $0.20{\leq}{\beta}(b1/B){\leq}0.75$. Existing yield line models for normal T-joints were investigated to be the main chord flange failure for the branch plate T-joint, and this proposal design formula was based on the theory of the yield line model. Finally, the value of the finite element method compared with the value of the test and theory for the T-joints verified the validity of the design formulae.