• 제목/요약/키워드: Stray Current

검색결과 112건 처리시간 0.024초

지하철 직류 급전시스템의 표유전류 실태 분석(I) 서울 지역 (Analysis of the Stray Current Conditions in Subway DC Electrification System (I) Seoul Metropolitan Area)

  • 하윤철;하태현;배정효;김대경;이현구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1364-1366
    • /
    • 2004
  • When an underground pipeline runs parallel with DC-powered railways, it suffers from electrolytic corrosion caused by the stray current leaked from the railway negative returns. Perforation due to the electrolytic corrosion may bring about large-scale accidents even cathodically protected systems. Traditionally, bonding methods such as direct drainage, polarized drainage and forced drainage have been used in order to mitigate the damage on pipelines. In particular, the forced drainage method is widely adopted in Seoul. In this paper, we report the analysis of the stray current conditions in Seoul subway DC electrification system.

  • PDF

지하전철구간 전기부식 특성에 관한 기초연구 (A Preliminary Study on the Electric Corrosion at Electrified Railroad)

  • 이철규;정우성;이덕희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.151-156
    • /
    • 2004
  • Although insulation equipment is installed, it is inevitable to avoid the stray current because rail is the return way of the direct current that is power of electric motor car. In this paper, by the investigation of the present state of underground facilities, and looking into the reason of electric corrosion, and analysis of corrosion accident cases of inside and outside of the country, fundamental data, to reduce of stray current and to prevent electric corrosion, were accumulated to enhance the safety of railway operation service.

  • PDF

직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구 (A study of Protection for electrical corrosion by stray current in DC railway system)

  • 이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF

Study of Stray-light Analysis and Suppression Methods for the Spectroscopic System of a Solar-radiation Observer Instrument

  • Zheng, Ru;Liu, Bo;Wang, Lingyun;Gao, Yue;Li, Guangxi;Li, Changyu
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.220-228
    • /
    • 2021
  • To improve the measurement accuracy of a solar-radiation observer instrument, aiming at the problem of multiorder-stray-light interference caused by the diffraction of the flat-field concave grating in the spectroscopic system, straylight suppression methods for different forms of optical traps are studied. According to the grating surface-scattering distribution-function model, the bidirectional scattering distribution function (BSDF) of a dust-polluted surface and the flat-field concave grating's transition area of the spectroscopic system is calculated, and a Lyot stop with blade baffle is designed to suppress this kind of stray light. For diffraction multiorder stray light, based on the theory of light-energy transmission, a design for precise positioning of the trench optical trap is proposed. The superiority of the method is verified through simulation and actual measurement. The simulation results show that in a spectroscopic system approximately 160 mm × 140 mm × 80 mm in size, the energy of the stray light is reduced by one order of magnitude by means of the trench optical trap and Lyot stop, and the number of beams is reduced from 5664 to 1040. The actual measurements show that the stray-light-suppression efficiency is about 69.4%, which is effective reduction of the amount of stray light.

Stray Load Loss Analysis of Canned Induction Motor for Hermetic Compressor

  • Yamazaki Katsumi;Haruishi Yoshihisa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.224-228
    • /
    • 2005
  • In this paper, we investigate the main components of stray load loss of induction motors for ammonia compressors. The variations of the losses at each part of the motor due to load are calculated by the combined 3-D-2D finite element method formulated by the mixed moving coordinate systems. The stray load loss is calculated from these results due the definition of IEEE standard-112. It is clarified that the core loss and the eddy current loss of the can increase due to load, which can be considered as the main part of the stray load loss.

로고우스키코일을 이용한 과도전류의 측정 (Measurement of Transient Current by using the Rogowski Coil)

  • 이복희;길경석;정승수;정상진
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF

Switching Transient Analysis and Design of a Low Inductive Laminated Bus Bar for a T-type Converter

  • Wang, Quandong;Chang, Tianqing;Li, Fangzheng;Su, Kuifeng;Zhang, Lei
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1256-1267
    • /
    • 2016
  • Distributed stray inductance exerts a significant influence on the turn-off voltages of power switching devices. Therefore, the design of low stray inductance bus bars has become an important part of the design of high-power converters. In this study, we first analyze the operational principle and switching transient of a T-type converter. Then, we obtain the commutation circuit, categorize the stray inductance of the circuit, and study the influence of the different types of stray inductance on the turn-off voltages of switching devices. According to the current distribution of the commutation circuit, as well as the conditions for realizing laminated bus bars, we laminate the bus bar of the converter by integrating the practical structure of a capacitor bank and a power module. As a result, the stray inductance of the bus bar is reduced, and the stray inductance in the commutation circuit of the converter is reduced to more than half. Finally, a 10 kVA experimental prototype of a T-type converter is built to verify the effectiveness of the designed laminated bus bar in restraining the turn-off voltage spike of the switching devices in the converter.

국가기간시설물의 전식대책(안) 및 그 적용 사례(1) (A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

매설배관과 직류전기철도의 표유전류 간섭분석 (Analysis of Stray Current Interference between Underground Pipelines and DC Electric Railways)

  • 하윤철;배정효;하태현;이현구;김대경
    • 한국가스학회지
    • /
    • 제10권3호
    • /
    • pp.41-47
    • /
    • 2006
  • 가스배관, 상수관, 송유관 등의 지중 매설배관이 직류 전기철도와 인접해 있는 경우, 전기철도 시스템의 귀선 회로로 사용되는 레일에서 누설되는 표유전류에 의해 이들 금속배관에는 전기적 부식, 즉 전식이 발생할 수 있다. 전식에 의한 집중 부식은 전기방식으로 보호되는 배관에 있어서도 지속적인 재료의 열화와 이에 따른 파손을 일으킬 수 있어 대형사고로 발전할 소지를 가지고 있다. 국내에서는 이러한 표유전류에 대한 대책으로 배관과 레일을 전기적으로 접속하는 배류법이 적용되고 있는데 특히 가스배관을 중심으로 한 강제배류법의 급속한 증가에 의해 간섭문제가 매우 복잡해지고 있다. 본 논문에서는 직류전기철도시스템과 매설배관 사이의 전기적 간섭 문제를 서울과 부산 지역에서 수행한 현장 실태조사의 결과를 통해 살펴본다.

  • PDF

직류급전계통에서의 레일전위 상승 분석 및 억제 방안 연구 (An Analysis on Rise of Rail Potential And A Study on Control Method for It in DC Feeding System)

  • 민명환;정호성;박영;김형철;신명철
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.680-685
    • /
    • 2011
  • Nowadays, in metropolitan railroad, DC feeding system is being generally applied. In order to reduce damages of electro-chemical corrosion caused by stray current and leakage current, in DC feeding system, rail is used as negative-polarity return conductor for traction load current. However, it has problem of rail potential increase and there are no adequate measures to prevent it in domestic. In this paper, we presented fundamental theory and related standards about rail potential increase. And then, we analyzed field testing data and simulated a variety of operations by using PSCAD/EMTDC as an analysis program of power system. In addition, voltage control device is suggested to prevent accidents caused by rail potential increase.