• Title/Summary/Keyword: Storage System

Search Result 6,934, Processing Time 0.038 seconds

A Study on the Development of Design Model of Ecological Park as Stormwater Storage Facilities (저류지 생태공원 설계모형 개발에 관한 연구)

  • Byeon, Wooil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.3
    • /
    • pp.1-16
    • /
    • 2006
  • The purpose of this study is to develop design model of ecological park as stormwater storage facilities. The results are as follows : First, the design model of ecological park as stormwater storage facilities consider ecological and landscape characteristics such as high efficiency of land use, function as disaster prevention, ecological water purification, formation of habitat for flora and fauna. Second, this study demonstrates two types of plane structure and eight types of designed section. They can be combined and designed depending on conditions of each site. The facilities of stormwater storage conduct disaster prevention system and ecological park. Retention pond in stormwater storage facilities for ecological park also should be made for ecological restoration in the site. Third, the ecological park provide the basis for ecological network from in-site to out-site. Therefore its conservation and restoration plan consider the ecosystems of the site. Fourth, the most important factor for maintenance and management for retention pond is keeping water quality. Sustainable Structured wetland Biotop system is suggested for ecological water purification system in the retention pond which is one of the constructed wetland system using multi-celled aquatic plant and pond. This system can also provide habitat for animals and plants, water friendly park for men, and beautiful landscape.

OASIS : Large-scale, wide-area storage system based on IP (OASIS : IP 기반의 대규모 광역 스토리지 시스템)

  • Kim, Hong-Yeon;Kim, Young-Chul;Jin, Ki-Sung;Kim, Young-Kyun;Lee, Mi-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2004.11a
    • /
    • pp.275-279
    • /
    • 2004
  • In this paper, a large-scale, wide-area storage system based on IP is proposed which is under development. OASIS is a storage system enforced with very high-scalability up to hundreds and thousands of clients over IP network, and it is able to extend the service to the wide area network. For this purpose, we adopt an storage interconnection technology based on IP, the object based storage technology and a clustered server architecture which provides high-scalability and availability to our system. This system can be utilized to provide network storage service which gains more reality with the incoming FTTH and WiBro services.

  • PDF

Design of a Solar Thermal Storage System Employing Heat Pipes and Molten Salts (히트파이프와 용융염을 사용하는 태양열 축열조의 설계)

  • Lee, Jung-Ryun;Boo, Joon-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.86-91
    • /
    • 2011
  • Thermal design was conducted for a solar thermal storage system in a medium-temperature range between $200^{\circ}C$ and $400^{\circ}C$. The system was composed of heat pipes as heat carrier and molten salts as phase-change storage material. Each heat pipe penetrated through the storage system and had two heat-exchanging sections at both ends to interact with high-and low-temperature steams, while it exchanged heat with molten salts in the middle section. During a heat-storage mode, the heat pipes transferred heat from the hot steam at one side to the molten salts and it transferred heat from the molten salt to the cold steam at the other side during the heat-dissipating mode. A tube-bank type heat exchanger theory was applied to this design task to meet the required inlet and outlet temperatures of the steams depending on the operation modes. Several design variables were considered including the lengths of evaporator and condenser of a heat pipe, traverse and longitudinal pitches of the pipe, and the number of rows of the heat pipes for two different molten salt baths. An optimum design results were presented with discussion.

  • PDF

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Development of Remote Monitoring System of Temperature Controller for Cold-Storage (저온냉장장치용 온도제어기의 원격 모니터링 시스템 개발)

  • Lim, Dae-Young;Ryoo, Young-Jae;Chang, Young-Hak;Moon, Chae-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2486-2488
    • /
    • 2003
  • This paper describes a remote monitoring system of temperature controller for cold-storage, of farm produce. In the cold-storage, it is important that farm produces are fresh. Unfortunately, when an operator goes out from the cold-storage temperature change could be occurred due to the various reasons, for an example, a valve of cooler is broken. The temperature change results in a serious problem of the quality of farm produce. To prevent the problem, the operator has to look to the current state of the temperature of the cold-storage, even he is in long away. Thus, the monitoring system to show the temperature should be required to the operator who can move away. Therefore, this paper propose of the remote monitoring system of the temperature. The proposed system is expected to help the operator's facilities, and the management of farm produce.

  • PDF

Development of Black Box for Home Battery Energy Storage System Connected with Solar Energy Generation (태양광발전 연계 가정용 배터리 에너지저장장치의 블랙박스 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1295-1302
    • /
    • 2016
  • In this paper, a black box, which is provided the reliability and user safety of home battery energy storage system connected with solar energy generation, is developed. In the developed scheme, a status and diagnosis data of battery management system, power conditioning system, solar energy generation and grid is measured. This status and diagnosis data is stored and displayed in the developed black box. In addition, this status and diagnosis data is stored and displayed in a monitoring system and a smart phone of user. A performance evaluation of the developed black box is carried out using emulator of home battery energy storage system connected with solar energy generation. Consequently, the developed black box is proved its superiority of the reliability and user safety.

Design and Implementation of Object Storage Engine for Large Multimedia Objects (대용량 멀티미디어 객체를 위한 객체저장엔진의 설계 및 구현)

  • Jin, Ki-Sung;Chang, Jae-Woo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.4
    • /
    • pp.376-388
    • /
    • 2002
  • Recently, although there are strong requirements to manage multimedia data, there are a few researches on efficient storage and retrieval of multimedia data. In this paper, we design an object storage engine which can store and retrieve various multimedia objects efficiently. For this, we design an object manager for storing a variety of multimedia data and an inverted file manager for indexing unformatted text objects. In addition, we implement the objects storage engine which can support concurrency control and recovery schemes of DBMS by integrating the object manager and the inverted file manager with the SHORE low-level storage system. Finally, we develope a TIROS(Thesis Information Retrieval using Object Storage engine) system in order to verify the usefulness of our object storage engine.

An Experimental Study on Characteristics of Heat Flow in the Cylindrical Storage Tank with Ice Ball (Ice Ball을 내장(內裝)한 빙축열조내(氷蓄熱槽內)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Jang, Y.G.;Lee, W.S.;Pak, J.W.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.99-109
    • /
    • 1998
  • The study on ice thermal storage system is to improve total system performance in actual air-conditioning facilities. To attain the high efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therfore the process flow must be piston flow in thermal storage tank. Ice packing factor is better on condition that the inflowing temperature is low, the flow direction in the thermal storage is upward and the cylindericalthermal storage type is used. This result shows that the cylinderical ice storage tank has better storage capacity than the rectangular type in case of the same porocity.

  • PDF

Transient Stability Enhancement of Power System by Using Energy Storage System (풍력터빈 발전기가 연계된 전력계통에서 에너지저장시스템이 과도안정도에 미치는 영향)

  • Seo, Gyu-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.592-597
    • /
    • 2019
  • A conventional method to improve transient stability in power system is the use of reactive power compensation devices such as STATCOM and SVC. However, this traditional method cannot prevent a rapid voltage collapse brought on by motors stalling due to system fault. On the other hand, ESS(Energy Storage System) provides fast-acting, flexible reactive and active power control. The fast active power compensation with energy storage system plays a significant role in transient stability enhancement after a major fault of power system. In this paper, transient stability enhancement method by using energy storage system is proposed for the power system including a dynamic load such as large motor. The effectiveness of energy storage system compared to conventional devices in enhancing transient stability of power system is presented. The results of simulations show that the simultaneous injection of active and reactive power can enhance more effectively transient stability.

Design and Implementation of Storage-based Data Sharing System in the Separate Network Environment (망 분리 환경에서 스토리지 기반의 데이터 공유 시스템 설계 및 구현)

  • Joe, In-Whee;Lee, Suk-Soon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5B
    • /
    • pp.477-483
    • /
    • 2011
  • In this paper, we propose the design and implementation of the storage-based data sharing system in the separate network environment to improve efficiency of data transmission. The previous system generates files per received packet and transmit files to another network through storage. This system causes inefficiency by reading unnecessary blocks, when it transmits a number of files through storage. Our proposed system deals with this inefficiency by adopting concept of snapshot. Consequently, we create one file with snapshot so that the number of files can be reduced and the file size can be optimized according to the block size. The proposed system improves the response time significantly with the minimized reading of unnecessary blocks, compared to the previous system.