• Title/Summary/Keyword: Storage Constant

Search Result 600, Processing Time 0.032 seconds

Determination of the Storage Constant for the Clark Model by based on the Observed Rainfall-Runoff Data (강우-유출 자료에 의한 Clark 모형의 저류상수 결정)

  • Ahn, Tae-Jin;Choi, Kwang-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1454-1458
    • /
    • 2007
  • The determination of feasible design flood is the most important to control flood damage in river management. Model parameters should be calibrated using observed discharge but due to deficiency of observed data the parameters have been adopted by engineer's empirical sense. Storage constant in the Clark unit hydrograph method mainly affects magnitude of peak flood. This study is to estimate the storage constant based on the observed rainfall-runoff data at the three stage stations in the Imjin river basin and the three stage stations in the Ansung river basin. In this study four methods have been proposed to estimate the storage constant from observed rainfall-runoff data. The HEC-HMS model has been adopted to execute the sensitivity of storage constant. A criteria has been proposed to determine storage constant based on the results of the observed hydrograph and the HEC-HMS model.

  • PDF

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Experimental Study on the Thermal Storage Efficiency Through Variable Porous Mainfolds in a Test Storage Tank (실험 저장조내의 유입구 형상변화에 따른 열 저장효율에 관한 실험적 연구)

  • Pak, Ee-Tong;Hwang, Sung-Il;Choi, Young-Il
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.37-43
    • /
    • 1989
  • This paper dealt with thermal storage efficiency due to difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank [$0.5m{\times}0.5m{\times}1.0m$] and the temperature of water flowing into the tank, flow rate of water flowing into the tank and shape of porous manifold which water flow into the tank through. As results of experiments; (1) When the flow rate was constant and the diameter of porous section decreased by 8mm, 6mm, and 4mm, the thermal storage efficiency increased. (2) When the diameter of porous section was constant and the difference ($T_{\infty}-Ti$) between the mean temperature of water in the storage tank and the temperature of water flowing into the tank increased by -30, -20, -10, 5, 10, 15 ($^{\circ}C$), the thermal storage efficiency increased. (3) When the($T_{\infty}-Ti$) was constant and the flow rate decreased by 0.8, 0.4, 0.25(LPM), the thermal storage efficiency increased. (4) When the shape of porous section was rigid, the thermal storage efficiency was the most effective, and with establishing flexible porous section or mesh, the effective thermal storage efficiency was obtained.

  • PDF

Fundamental researches on the storage function model and It's application (저유함수법과 그 응용에 관한 기초적 연구)

  • 남궁달
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.3
    • /
    • pp.90-98
    • /
    • 1984
  • In this paper, the anthor made a basic study of the storage function model and examined several constants in applying the storage function model to flood run-off analysis by dealing with the data in the Supyung and Hoyng Syung watershed, the applicabilities of the storage function model are examined by searching this optimum model parameters in two watersheds. The results are summarized as follows, 1) The optimum values of the exponential constants, P, in the storage function model showed to be 0.77 to 0.87 in two watersheds observed, therefore it was confirmed that the storage fumction model was approaching to the surface runoff model. 2) It was confirmed that the interval of variation of the storage constant, K, Showed to be larger than that of the exponential constant, p. 3) Relative erros in the discharge obtained by using the storage function model and the SDFP mothod showed to be 20 and 17 percent respectively to the observed discharge, therefore it was confirmed that the applicability of the storage function model using the SDFP method are excellent for runoff analysis. 4) A simple method is proposed for estimating the lag time in the storage function model.

  • PDF

Parallel reservoirs system operation using NYC-Space Allocation-Rule (NYC-Space Allocation Rule을 이용한 병렬저수지 연계운영)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.533-542
    • /
    • 2005
  • In this study, an optimization technique was developed from the application of Allocation Rule. Average Allocation coefficients of the Andong and Imha dam compare constant water supply condition with vary water supply condition that are above the contribute ratio $67\%\~50\%$ the Andong dam in Rule(A)-Rule(C). In the Refill Season, Andong dam water supply contribution is higher than Imha dam at the Control point water supply. In the Allocation analysis results, Rule(A) is calculated storage ratio because Andong dam contribute to Control point larger than Imha dam which Andong dam storage is larger than Imha dam storage. Rule(B) calculated sum of the storage and inflow ratio for Andong dam and Imha dam, as Andong dam contribution is higher than Imha dam. Rule(C) calculated that sum of storage, inflow and water supply is divided average storage ratio, as the best results of the Allocation coefficients and water supply capacity. The results of storage analysis is larger vary water supply condition than constant water supply condition and the results of water supply analysis is larger vary water supply condition than constant water supply condition. Water supply deficit is decrease $30\%$ for vary water supply condition.

Effect of Pre-treatment and Storage Conditions on the Quality Characteristics of Ginger Paste

  • Choi, Eun-Jeong;Lee, Kyung-A;Kim, Byeong-Sam;Ku, Kyung-Hyung
    • Preventive Nutrition and Food Science
    • /
    • v.17 no.1
    • /
    • pp.46-52
    • /
    • 2012
  • This study was performed to investigate the effects of pre-treatment and storage temperature and periods on the quality characteristics of ginger paste. The pH of the ginger paste remained constant during room temperature storage but increased with prolonged refrigerated storage periods. During five months of frozen storage, regardless of pre-treatment, the pH of most of the samples decreased slightly and then remained constant. In the color value of ginger paste stored at room temperature, the samples with and without chemical additives changed in color more prominently than fermented or pasteurized samples. Intriguingly, the color value for samples containing chemical additives changed more dramatically when stored under refrigerated conditions. However, the L, a, and b values of samples stored under frozen storage conditions did not change even after ten months. Most of the samples contained glucose and fructose, except for the fermented samples. The free sugar content of samples slowly decreased with increasing storage periods, while the organic acid content generally decreased also, regardless of sample type. Depending on pre-treatment and storage temperature, the gingerol content of the samples was either retained or decreased with prolonged storage time.

Improved Parameter Computation Method Applications of Storage Function Model for the Han River Basin (저류함수모형 매개변수 산정 개선방법의 한강유역 적용)

  • Jeong, Dong-Kug;Jeon, Yong-Woon;Lee, Beum-Hee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.149-158
    • /
    • 2008
  • The parameters of each basin, required for the accurate analysis of flood runoff using Storage Function Model, are estimated. Prior to the estimation, sensitivity analysis and extraction of new regional topographic factors for Han River basin are conducted. Based on the result, the outflow constant of basin model is calculated through regression analysis in relation with pre-flood runoff depth. The storage constant of basin model is derived by the optimum storage constant equation, according to the flood event of each basin. The model using the mentioned parameters was compared with K-Water model of Korea Water Resources Corporation and the model of Han River Flood Control Office, and proved to correspond to the observed hydrograph more.

Energy Analysis of Constant-Pressure Compressed Air Energy Storage (CAES) Generation System (정압식 압축공기저장(CAES) 발전 시스템 에너지 분석)

  • Kim, Young-Min;Lee, Sun-Youp;Lee, Jang-Hee
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.178-184
    • /
    • 2011
  • Compressed Air Energy Storage (CAES) is a combination of energy storage and generation by storing compressed air using off-peak power for generation at times of peak demand. In general, both charging and discharging of high-pressure vessel are unsteady processes, where the pressure is varying. These varying conditions result in low efficiencies of compression and expansion. In this paper, a new constant-pressure CAES system to overcome the current problem is proposed. An energy analysis of the system based on the concept of exergy was performed to evaluate the energy density and efficiency of the system in comparison with the conventional CAES system. The new constant-pressure CAES system combined with pumped hydro storage requires the smaller cavern with only half of the storage volume for variable-pressure CAES and has a higher efficiency of system.

Study for comparison of storage lifetimes estimation between constant and time-variant variance of degradation data (열화데이터의 등분산 가정에 따른 저장수명예측 비교 연구)

  • Back, Seungjun;Son, Youngkap;Park, Sanghyun;Lee, Munho;Kang, Insik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.154-156
    • /
    • 2017
  • Constant variance of degradation data over time has been generally assumed to estimate storage lifetime using destructive, accelerated degradation data over time. However, performance data of ammunitions deteriorate over time, and the standard deviation would tend to increase over time. This paper shows storage lifetime comparison results for constant variance and time-variant variance assumptions of degradation data over time, and proposes that time-variant variance assumption should be considered to increase accuracy in lifetime estimation.

  • PDF

Short-term Storage and Cryopreservation of Abalone (Haliotis discus hannai) Sperm

  • Kang, Kyoung-Ho;Kim, Jae-Min;Kim, Young-Hun
    • The Korean Journal of Malacology
    • /
    • v.20 no.1
    • /
    • pp.17-26
    • /
    • 2004
  • In present study, attempts were made to preserve abalone (Haliotis discus hannai) sperm in liquid form at low temperature, to evaluate the effect of various diluents in short-term storage on sperm, and cryopreservation procedures were optimized for the cryoprotectants and freezing rates, as well as the motility, survival rate, and the ultrastructural changes of sperm after short-term storage and cryopreservation were observed. The abalone sperm reached maximum motility until about 4 min after activation. The motility was constant for about 16 min, after which it dropped gradually, and about 50 min later all motility ceased. In Hanks' balanced salt solution (HBSS, 300 and 400 mOsmol/kg) and 150, 250 and 350 mOsmol/k artificial seawater (ASW), the sperm was immotile. After 100% ASW was added, motility of those sperm, which are in 300, 400 mOsmol/kg HBSS, 250, 350 mOsmol/kg ASW, could be again restored incompletely. Sperm motility can be maintained for 20 days of cold storage only in ASW of 850 and 1200 mOsmol/kg. A high motility index of 3.5-4.5 was observed for the first 8 days in 850 and 950 mOsmol/kg ASW. In other diluents sperm motility was constant less than 10 days, and the motility index was obviously lower than that of sperm in 850 and 1200 mOsmol/kg ASW. After 20 days of cold storage, survival rates of 10.2%-20.7% were obtained in ASW and 300 mOsmol/kg HBSS, and that in 400 HBSS (65.3%) was significantly higher than others. The constant period of sperm motility stored in 850 mOsmol/kg ASW was obviously longer than that in 1200 mOsmol/kg ASW after 6 days of storage. The sperm plunged into liquid nitrogen all died except that sperm using 15% glycerol as cryoprotectant restored 10.4% of motility. The highest motility index (3.4) was obtained with 5% glycerol and freezing procedure: $-50^{\circ}C$/min from $20^{\circ}C$ to $-80^{\circ}C$.

  • PDF