• Title/Summary/Keyword: Stiffness Control

검색결과 1,109건 처리시간 0.025초

종합병원 간호사들의 피로자각증상과 요통 (Industrial Fatigue and Low Back Pain of the Nurses in General Hospital)

  • 김순례;조동란
    • 한국직업건강간호학회지
    • /
    • 제8권2호
    • /
    • pp.162-168
    • /
    • 1999
  • To investigate industrial fatigue and low back pain, the questionaire survey for subjective symptoms of fatigue and low back pain was carried out 305 nurses in general hospital in Korea. Nurses participated to this study were divided into low back pain group(LBP) and control group, according to the self-reports by written questionaires. The subjective sysptoms of fatigue comprised three groups of 10 items each, representing dullness and sleepiness(level of cerebral activation), difficulty in concentration(level of motivation) and bodily projection of fatigue. The resultant data were processed for $x^2$-test, t-test to confirm the associations. The results were as follows: 1. 28 items of fatigue subjective symptoms exept two item, 'feel thirsty and 'feel ill', were directly associated with low back pain. 2. The percentage of fatigue complaint were significantly higher in LBP group than control. 3. Of the 30 items of fatigue subjective symptoms, the highest percentage was accounted for 'legs feel heavy', 'eye strain', 'feel stiffness in the neck or the shoulders' followed by 'feel like lying', 'whole body feels tired', 'feel a pain in the low back', 'feel drowsy' and in the order of sequence. 4. The average weighted score for the first group of fatigue items(dullness and sleepiness) was the largest among three groups and was followed by the second group(difficulty in concentration) and the third group (bodily projection of fatigue) in the order of sequence, suggesting the heavier mental and shift work stress of the female workers.

  • PDF

Performance validation and application of a mixed force-displacement loading strategy for bi-directional hybrid simulation

  • Wang, Zhen;Tan, Qiyang;Shi, Pengfei;Yang, Ge;Zhu, Siyu;Xu, Guoshan;Wu, Bin;Sun, Jianyun
    • Smart Structures and Systems
    • /
    • 제26권3호
    • /
    • pp.373-390
    • /
    • 2020
  • Hybrid simulation (HS) is a versatile tool for structural performance evaluation under dynamic loads. Although real structural responses are often multiple-directional owing to an eccentric mass/stiffness of the structure and/or excitations not along structural major axes, few HS in this field takes into account structural responses in multiple directions. Multi-directional loading is more challenging than uni-directional loading as there is a nonlinear transformation between actuator and specimen coordinate systems, increasing the difficulty of suppressing loading error. Moreover, redundant actuators may exist in multi-directional hybrid simulations of large-scale structures, which requires the loading strategy to contain ineffective loading of multiple actuators. To address these issues, lately a new strategy was conceived for accurate reproduction of desired displacements in bi-directional hybrid simulations (BHS), which is characterized in two features, i.e., iterative displacement command updating based on the Jacobian matrix considering nonlinear geometric relationships, and force-based control for compensating ineffective forces of redundant actuators. This paper performs performance validation and application of this new mixed loading strategy. In particular, virtual BHS considering linear and nonlinear specimen models, and the diversity of actuator properties were carried out. A validation test was implemented with a steel frame specimen. A real application of this strategy to BHS on a full-scale 2-story frame specimen was performed. Studies showed that this strategy exhibited excellent tracking performance for the measured displacements of the control point and remarkable compensation for ineffective forces of the redundant actuator. This strategy was demonstrated to be capable of accurately and effectively reproducing the desired displacements in large-scale BHS.

TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 1:해석적 연구) (Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method (Part 1:Analytical Study))

  • 정명철;송정원;송진규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.141-147
    • /
    • 2018
  • 본 연구에서는 TS 내진보강공법의 내진보강 효과를 검증 할 목적으로 TS 댐퍼(Tension Spring-Damper)를 설치한 철근콘크리트 골조를 대상으로 한 반복 주기하중 재하 실험을 수행 하였다. 실험체는 기준 실험체인 무보강 골조 실험체와 3개의 보강 골조 실험체의 총 4개이며, 실험의 변수는 댐퍼 설치 여부, 댐퍼의 형상 및 시공방법이다. 그 결과 창호 내부 삽입 형식의 시공방법이 강도와 강성의 측면에서 2배가량, 외부 부착형식의 시공 방법이 에너지 소산의 측면에서 2배가량의 성능 향상을 나타내어 TS 내진보강공법이 현장 적용성과 내진보강 효과가 우수한 공법임을 확인 할 수 있었다.

준고온 재생 아스팔트 콘크리트의 기본특성 평가 (Evaluation of Fundamental Properties of Warm-mix Recycled Asphalt Concretes)

  • 김남호;김진철;홍준표;김광우
    • 한국도로학회논문집
    • /
    • 제12권4호
    • /
    • pp.111-120
    • /
    • 2010
  • 본 연구는 준고온 공법을 이용한 재생 아스팔트 콘크리트의 강도특성을 평가하기 위해 이루어졌다. 굵은 골재 최대치수 13mm의 화강암과 침입도 60-80인 신규 바인더 60-80을 재생 혼합물을 제조하는데 사용하였다. 배합설계는 RAP(굵은 입자 : 잔입자=6 : 4) 첨가비율 20%와 30%를 사용하였고 GPC, 침입도, 절대점도, 동점도를 준고온 첨가제(Evotherm와 Sasobit)의 첨가 함량을 결정하기 위하여 측정하였다. LD(low-density poly ethylene)를 본 연구에서 준고온 재생 아스팔트 혼합물의 개질제로 사용하였다. 본 연구에서는 8개의 준고온 재생 혼합물(2 RAP함량 ${\times}$ 2 준고온 첨가제 ${\times}$ 2 개질제)뿐만 아니라 2개의 일반 재생 혼합물, 1개의 가열혼합 일반혼합물(control)까지 총 11개의 혼합물을 제조하였다. 변형강도 시험, 간접인장강도 시험, 수분민감성 시험, wheel tracking을 통한 소성변형 시험을 준고온 재생혼합물의 기본 특성을 평가하기 위하여 수행하였다.

자동차 변속기용 정밀 부품의 용접변형 감소화에 관한 연구 (A Study on the Mitigation of Welding Distortion of a Precision Component for Automobile Transmission)

  • 정회윤;김재웅;윤석철
    • Journal of Welding and Joining
    • /
    • 제30권4호
    • /
    • pp.31-37
    • /
    • 2012
  • In recent years, a demand for precision-welding is increasing in wide industrial fields for getting a high quality welded structures. Although laser welding is commonly used for precision-welding, gas tungsten arc (GTA) welding is also attempted as a precision-welding due to the cost benefit. However, welding heat causes an uneven temperature distribution leading to welding deformation. Since it causes geometric errors and degrades product quality, welding distortion recently rises as an important issue in the field of automobile parts. To control welding deformation, it is needed to design in shapes that can maximize stiffness against deformation during welding; control the welding sequence; minimize heat input; and weld allowing reverse deformation; etc. Thus it is necessary to find the one, among such approaches, that can minimize the deformation range by mathematical analysis and understand how effective it would be when it is actually used in industrial fields. This study performs analyses by numerical calculations and experiments for the De-Tent Lever, one of transmission part that requires precision the most among automobile parts, as the subject of experiment. Decrease in welding deformation is required for this part, since there is currently a trouble in guaranteeing precision due to angular deformation by welding between boss and plate. Finally the ways to minimize welding deformation has been suggested in this study through analyses on it.

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The Effect of Dynamic Property of Absorbing Sheet on the Amplification of Heavy Weight Floor Impact Noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.651-657
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50 dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6~7 dB compared to the conventional slab system at the optimal stud location.

허리 불안정성이 있는 허리통증 환자에게 실시한 자가-복합 운동프로그램이 통증과 기능, 심리사회적, 균형 능력 그리고 배가로근에 미치는 효과 (Effect of Self-Complex Exercise Program on Pain, Function, Psychosocial, Balance Ability, and TrA Muscle in Patients with Lumbar Instability: A Randomized Controlled Trial)

  • 윤종혁;정대근;박삼호
    • 대한통합의학회지
    • /
    • 제10권2호
    • /
    • pp.73-83
    • /
    • 2022
  • Purpose : Low back pain (LBP) is reported as a risk of experiencing musculoskeletal disorders due to muscle stiffness and hypokinetics. The lumbar spine in an unstable state causes imbalance and lumbar instability. Therefore, This study examined the effects of lumbar stabilization exercise and self-complex exercise program on pain, function, psychosocial level, static balance ability, and transverse abdominal muscle (TrA) thickness and contraction ratio in patients with lumbar instability. Methods : The design of this is a randomized controlled trial (RCT). Twenty-six LBP patients participated in this study. Screening tests were performed and assigned to the experimental group (n=13) and control group (n=13) using a random allocation program. Both groups underwent a lumbar stabilization exercise program. In addition, the experimental group implemented the self-complex exercise program. All interventions were applied three times per week for four weeks. The quadruple visual analog (QVAS), the Korean version of the Oswestry disability index (K-ODI), Korean version of fear-avoidance belief questionnaire (FABQ), static balance ability, TrA thickness, and contraction ratio were compared to evaluate the effect on intervention. Statistical significance was set at 𝛼=.05. Results : Both groups showed significant differences before and after the intervention in QVAS, K-ODI, FABQ, static balance ability, and TrA thickness in contraction (p<.05). In addition, significant differences in K-ODI and FABQ were observed between the experimental group and control group (p<.05). Conclusion : A lumbar stabilization exercise and self-complex exercise program resulted in reduced dysfunctions, psychosocial stability in patients with lumbar instability. Therefore, Lumbar stabilization exercise and self-complex exercise program for patients with lumbar instability are effective method with clinical significance in improving the function and psychosocial stability.

Improving the seismic behavior of diagonal braces by developing a new combined slit damper and shape memory alloys

  • Vafadar, Farzad;Broujerdian, Vahid;Ghamari, Ali
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.107-120
    • /
    • 2022
  • The bracing members capable of active control against seismic loads to reduce earthquake damage have been widely utilized in construction projects. Effectively reducing the structural damage caused by earthquake events, bracing systems equipped with retrofitting damper devices, which take advantage of the energy dissipation and impact absorption, have been widely used in practical construction sites. Shape Memory Alloys (SMAs) are a new generation of smart materials with the capability of recovering their predefined shape after experiencing a large strain. This is mainly due to the shape memory effects and the superelasticity of SMA. These properties make SMA an excellent alternative to be used in passive, semi-active, and active control systems in civil engineering applications. In this research, a new system in diagonal braces with slit damper combined with SMA is investigated. The diagonal element under the effect of tensile and compressive force turns to shear force in the slit damper and creates tension in the SMA. Therefore, by creating shear forces in the damper, it leads to yield and increases the energy absorption capacity of the system. The purpose of using SMA, in addition to increasing the stiffness and strength of the system, is to create reversibility for the system. According to the results, the highest capacity is related to the case where the ratio of the width of the middle section to the width of the end section (b1/b) is 1.0 and the ratio of the height of the middle part to the total height of the damper (h1/h) is 0.1. This is mainly because in this case, the damper section has the highest cross-section. In contrast, the lowest capacity is related to the case where b1/b=0.1 and the ratio h1/h=0.8.

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Seismic performance of RC columns retrofitted using high-strength steel strips under high axial compression ratios

  • Yang, Yong;Hao, Ning;Xue, Yicong;Feng, Shiqiang;Yu, Yunlong;Zhang, Shuchen
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.345-360
    • /
    • 2022
  • In this paper, the impact on seismic performance of an economical effective technique for retrofitting reinforced concrete (RC) columns using high-strength steel strips under high axial compression ratios was presented. The experimental program included a series of cyclic loading tests on one nonretrofitted control specimen and three retrofitted specimens. The effects of the axial compression ratio and spacing of the steel strips on the cyclic behavior of the specimens were studied. Based on the test results, the failure modes, hysteretic characteristics, strength and stiffness degradation, displacement ductility, and energy dissipation capacity of the specimens were analyzed in-depth. The analysis showed that the transverse confinement provided by the high-strength steel strips could effectively delay and restrain diagonal crack development and improve the failure mode, which was flexural-shear failure controlled by flexural failure with better ductility. The specimens retrofitted using high-strength steel strips showed more satisfactory seismic performance than the control specimen. The seismic performance and deformation capacity of the retrofitted RC columns increased with decreasing axial compression ratio and steel strip spacing. Based on the test results, a hysteretic model for RC columns that considers the transverse confinement of high-strength steel strips was then established. The hysteretic model showed good agreement with the experimental results, which verified the effectiveness of the proposed hysteretic model. Therefore, the aforementioned analysis can be used for the design of retrofitted RC columns.