• Title/Summary/Keyword: Sterilization methods

Search Result 227, Processing Time 0.02 seconds

Effect of Microbial Treatment Methods on Biogrout (미생물 처리 방법이 바이오그라우트에 미치는 영향)

  • Kim, Daehyeon;Park, Kyungho;Kim, Hochul;Lee, Yonghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.51-57
    • /
    • 2012
  • The purpose of study is to understand the possibility of biogrout of soil induced by bacteria. Microbial Calcium Carbonate Precipitation(MCP) has been analysed using the microorganism Bacillus Pasteurii. In order to understand the biogrout of soft ground treated with microbial calcium carbonate precipitation, four types of specimens(sterilization soil, non-sterilization soil, reaction solution and microorganism solution with pre-treatment mix and reaction solution and microorganism solution with post-treatment mix) were made. Scanning Electron Microscope(SEM), EDX and X-ray diffraction(XRD) analyses were performed on the soft ground specimens. On the basis of the preliminary results, it appears that microbial treatment methods using calcium carbonate precipitation may be possible to improve property of biogrout.

A Study of Sterilization Effect of Long-wavelength UVA-LED Irradiation on Bacteria Causing Eye Diseases (장파장의 자외선 LED 광원을 이용한 안질환 세균의 살균효과)

  • Lee, Cheol-Woo;Jeong, Kyeong-In;Hwang, Kwang-Ha;Lee, Seok-Ju;Yoo, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The purpose of this study is to demonstrate inactivation effect of UVA-LED ultraviolet radiation upon Pseudomonas aeruginosa and Staphylococcus aureus which are the major bacteria causing eye diseases. Methods: The small sterilization device was made using UVA-LED of 400 nm. After Pseudomonas aeruginosa was diluted to $10^{-7}$ and Staphylococcus aureus to $10^{-5}$ and diluted solutions were put onto each liquid medium. They were irradiated by 400 nm of UVA for different amount of time; 15 min, 30 min, 60 min, 120 min, 240 min, 360 min and 480 min each. Results: The data from sterilization test was solved to regression line equation and the target log inactivation was obtained. The 3 log inactivation UV irradiation value of Pseudomonas aeruginosa was 54,847 UV dose ($mJ/cm^2$) and irradiation time was 135.42 min while the 3 log inactivation of Staphylococcus aureus was 39,066 UV dose ($mJ/cm^2$) and irradiation time was 98.72 min. Conclusions: The inactivation effect of sterilization method using 400 nm of UVA-LED upon Pseudomonas aeruginosa and Staphylococcus aureus has been verified and it is considered as a useful method in inactivating the contact lenses.

Outcomes of IVF-ET in Infertile Patients with Failed Microsurgical Reversal of Tubal Sterilization (미세수술적 난관복원술 후 임신에 실패한 환자에서의 체외수정시술 결과)

  • Kim, Seok-Hyun;Hong, Joon-Seok;Ku, Seung-Yup;Suh, Chang-Suk;Choi, Young-Min;Kim, Jung-Gu;Moon, Shin-Yong;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.4
    • /
    • pp.307-315
    • /
    • 2001
  • Objective: To evaluate the clinical outcomes and influencing factors of in vitro fertilization and embryo transfer (IVF-ET) in patients with failed pregnancy after microsurgical reversal of tubal sterilization. Materials and Methods : From January, 1997 to December, 2000, IVF-ET was performed in two groups; the study TR (tubal reanastomosis) group consisted of 147 cycles in 66 patients with failed microsurgical reversal of tubal sterilization, and the control group of 115 cycles in 67 patients with bilateral tubal occlusion (BTO). The two groups were evaluated and compared for clinical characteristics, clinical pregnancy rates, and factors influencing the outcomes of IVF-ET. Results: Compared with the control BTO group, age and the previous parity were significantly higher ($36.3{\pm}2.7$ vs. $33.6{\pm}2.0$ years, p<0.05; $1.6{\pm}0.7$ vs. $0.2{\pm}0.4$, p<0.05), and the clinical pregnancy rate per cycle was significantly lower (23.8% (35/147) vs. 29.3% (34/115), p<0.05) in the TR group. Difference in the clinical pregnancy rates was age-related, since there was no significant difference between the two groups, except for the previous parity ($1.6{\pm}0.7$ vs. $0.1{\pm}0.3$, p<0.05), when the patients aged 37 years or older were excluded. No difference was found in terms of the following: the proportion of controlled ovarian hyperstimulation (COH) cycles with GnRH agonist ultrashort protocol, the duration of COH, the dosage of gonadotropins used, and the numbers of oocytes retrieved and of embryos transferred, irrespective of age correction. Conclusions: The outcomes of IVF-ET following the failed microsurgical reversal of tubal sterilization depend upon patient age. The previous fertility of patients does not seem to be a factor of better IVF-ET prognosis.

  • PDF

Voluntary Sterilization in Rural Korea (일부농촌의 불임수술자 실태)

  • Kim, Joong-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.80-85
    • /
    • 1977
  • The Korean family planning program began in 1962, originating both in a concern for family well-being and in a concern over a high population growth rate which was cancelling advances in economic capacity. The new program was frank and vigorous in its advocacy of birth control. In recent years, voluntary sterilization as a family planning method has many attributes that cause users of contraceptives to regard it as an ideal method in Korea. A point of these view, author performed a follow-up study on effects of vasectomy and tubal ligation on sociomedical aspects of total 136 men sterilized and 96 women sterilized in Sunsan Gun, Kyungpook Province as of July, 1977. The results were summerized as follows: An average age of vasectomized men was 37.0 and that of tubal ligated women, 34.9. The average duration of marital life was 13.9 years in men sterilized and 14.6 years in women sterilized. An average number of living children at the time of sterilization was 3.6 in men sterilized and that of living children, 3.7 in women sterilized. The most predominant reason for the sterilization was birth control in both (91% in men, 52% in women) and the most common motivating socilitator was family planning field workers (71% in men, 48% in women). About 51 percent of men sterilized and 50 percent of women sterilized were used contraceptive methods before the operation. Experience of induced abortion is reported in 65 percent of wives of men sterilized and 64 percent of women sterilized. In sexual feeling after sterilization, respondents shelved increasing coital frequency 21 percent in men sterilized and 10 percent in women sterilized. Sixty-five percent in men sterilized and 64 percent in women sterilized would recommend the operation to others.

  • PDF

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

Job Description of Nurses in Central Supply Department using DACUM Technique (데이컴 기법을 이용한 중앙공급 간호사의 직무분석)

  • Oh, Eun Sil;Song, Soon Duk;Choi, E-Jung;Chun, Hyun Sook;Han, Hwa Soon;Ryoo, Sung Suk;Hwang, Moon Suk;Lee, Mi Kyoung
    • Journal of Korean Clinical Nursing Research
    • /
    • v.20 no.3
    • /
    • pp.303-312
    • /
    • 2014
  • Purpose: This study aimed to use the DACUM analysis technique and identify the job description among nurses of the Central Supply Department, in order to clarify their duty and task descriptions, identify the characteristics of job. Methods: Through a DACUM workshop, job descriptions, and the job duties and tasks were derived. A total of 150 nurses from the Central Supply Departments of medical Institutions over 100 beds were surveyed using drafting and a job analysis table. Individual jobs' frequency, importance and difficulty were measured using a 3-point scale, and the results were analyzed using SPSS. Results: The nurses' job in the Central Supply Department consisted of 13 duties and 64 tasks. Duties with highest importance and difficulty was 'sterilization assurance system', the second was 'employee safety management' and the duty with highest frequency was 'manage packaging before sterilization'. Conclusion: This study clarified the types of nursing jobs in the Central Supply Departments, as well as identified the job characteristics and status in the given setting. Given the sterilization assurance system for preventing hospital infection, and safety management for ensuring work environment safe were found to be important duties, it is suggested for the department to stress those important jobs for managing hospital safety.

Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process (치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성)

  • Jeong, Yong-Hoon;Moon, Young-Pil;Lee, Chung-Hwan;Yu, Jin-Woo;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

Ozone Processing Storage Characteristic of Main Herb Medicines (주요 한약재의 오존처리저장 특성)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • Recently, many storing methods were applied to keep quality of herb medicines during storage. Among of thent we tried to research a method to store after dissolving remaining harmful bacillus and agricultural chemicals of herb medicines. We confirmed that ozone processing is superior at the sterilization of bacteria and virus from the leading research about ozone generator, and then we made research method to apply with the sterilization and storing processing of herb medicines using ozone (OPS). In this study we chose herb medicines of 4 kinds which have been sold much in the market, evaluated the characteristics. Namely, we used ozone lamp in a storage system and investigated the sterilization characteristic of herb medicines. We executed a quantitative analysis of the general ingredient and the physiological activity ingredient to investigate whether the original ingredient and the quality of herb medicines is preserved, after doing an ozone md storing processing for a long term.

A study on the synthesis and characterization of nano-sized metal oxide for conservation treatment of paper records (종이기록물 보존처리를 위한 나노크기의 금속산화물 합성 및 특성 고찰 연구)

  • Do, Young-Woong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1222-1227
    • /
    • 2014
  • Recording materials are the valuable historical and cultural parts themselves as well as the methods for exchanging informations. Therefore, the appropriate conservation treatments should be conducted to the recording materials respectively. In case of the paper records, some particular conservation treatments such as a deacidification and a sterilization are necessary to prevent both bio and chemical deteriorations. In this research, the nano-scaled ZnO and MgO with 10~30nm size were prepared for the effective and stable conservation treatment of the paper records. Deacidification and sterilization effect of nano compounds were excellent and since nano compounds had almost 100% purity(free from Pb, Cd, As), the additional damages caused by the heavy and toxic metals should not be occur to the books and papers.

A Study on Worker Exposure to Ethylene Oxide in Central Supply Sterilizing Room of Hospital (일부 종합병원 중앙공급실에서의 Ethylene Oxide 노출에 관한 연구)

  • Seo, Sang Ok;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.68-86
    • /
    • 1995
  • This study was conducted at five Ethylene Oxide(EO) sterilizing processes in hospitals located in Seoul from August 8 to August 30, 1994. The main purposes of this study were to assess the TWA(Time Weighted Average) and short term exposures to EO and to evaluate factors affecting EO concentrations in sterilizing room. Results are summarized as follows. 1. The TWA concentrations of the sterilizing operators ranged from <0.005ppm to 3.04ppm and those of two sterilizing rooms out of five exceeded 1ppm, the Korean and ACGIH standards. 2. When the door of the sterilizer is opened at the end of the sterilization cycle, the short term concentrations of operators ranged from <0.005ppm to 11.4ppm, and those of three sterilizing room out of five exceeded 5ppm, the ACGIH short term exposure limit(STEL). The short term concentrations of area samples ranged from 0.24ppm to 49.2ppm and those of four sterilizing room out of five exceeded 5ppm. 3. Factors affecting EO exposure level were aeration type, the location of storage site for sterilized item, amount of gas, use period of sterilizer(p<0.005). 4. Following recommendations are suggested to minimize exposure to EO. The use of EO gas should be reduced by using another available sterilization methods, and the sterilizers and gas tank storage site should be isolated from, other work areas. Combination of local and general ventilation system should be installed. Metal carts or baskets for sterilization load should be used, and work environment and medical monitoring should be performed regularly.

  • PDF