• Title/Summary/Keyword: Stereotactic

Search Result 408, Processing Time 0.033 seconds

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Successful Treatment of Infantile Fibrosarcoma Spinal Metastasis by Chemotherapy and Stereotactic Hypofractionated Radiotherapy

  • Lo, Cheng-Hsiang;Cheng, Shin-Nan;Lin, Kuen-Tze;Jen, Yee-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.6
    • /
    • pp.528-531
    • /
    • 2013
  • We report a case of infantile fibrosarcoma in an 8-month-old boy manifested as a right-sided lower leg mass. Repeated local recurrence and distant metastasis were noted during the following three-year period. Whole body fluoro-deoxyglucose positron emission tomography scan revealed an asymptomatic metastasis involving the fourth lumbar vertebrae. The patient received chemotherapy (VAC regimen) with Cyberknife$^{(R)}$ stereotactic hypofractionated radiotherapy (26 Gy; 4 fractions). This treatment reduced tumor size by 23% without acute radiation toxicity even after 33 months. This case suggests that combining chemotherapy and this form of radiotherapy may be safe and effective against childhood spinal metastasis.

Intracranial Undifferentiated Sarcoma Arising from a Low-Grade Glioma : A Case Report and Literature Review

  • Kim, Bum-Joon;Kim, Jong-Hyun;Chung, Hung-Seob;Kwon, Taek-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.6
    • /
    • pp.469-472
    • /
    • 2015
  • Undifferentiated sarcomas are rarely identified in the intracranial region. A 23-year-old man was admitted with a chief complaint of headache. Initial magnetic resonance images showed signs of low-grade glioma in the frontal lobe. Stereotactic biopsy was performed, and a diagnosis of diffuse astrocytoma was confirmed. Three months later, the patient presented with a high-grade tumor as seen on imaging studies. He underwent total resection of the tumor and histopathological tests identified an undifferentiated sarcoma. The patient died eight months later due to massive tumor bleeding. To the best of our knowledge, this is the first report of undifferentiated sarcoma arising from low-grade glioma without any chemotherapy or radiotherapy.

Development of 3D Mutil-volume Visualization System for Stereotactic Surgery (뇌정위 수술계획을 위한 다원 3차원 영상가시화 시스템의 개발)

  • Choi, Jae-Jeong;Ge, Jin;Shin, Yeong-Gil
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10c
    • /
    • pp.612-614
    • /
    • 1998
  • 뇌정위 수술(Stereotactic Surgery)은 컴퓨터 단층영상과 자기공명 영상 같은 3차원 영상을 이용하여 뇌병변의 위치를 입체적으로 정확히 파악하여 정상 뇌에 대한 손상을 최소화하며 병변을 수술하는 기법이다. 본 논문에서는 수술 받을 환자의 컴퓨터 단층영상과 자기공명 영상 등 다양한 종류의 3차원 볼륨 데이터를 전처리한 다음 동일한 3차원 공간 내에서 정렬시켜 선택적 또는 동시적으로 3차원 영상을 가시화 하는 기법을 제안한다. 또한 3차원 영상에서 뇌정위 수술의 삽입점과 목표점을 지정할 수 있는 기능을 지원하며 수술 경로에 따른 가상 수술의 시뮬레이션을 통하여 수술 경로의 안전성을 검증할 수 있게 하였다.

  • PDF