• Title/Summary/Keyword: Stereomicroscope

Search Result 215, Processing Time 0.024 seconds

Effect of Gonadotropin on $Ca^{++}$ Uptake in Follicle-Enclosed Mouse Oocytes Cultured in Vitro (배양된 생쥐여포에서 $Ca^{++}$ Uptake에 대한 Gonadotropin의 영향)

  • Bae, In-Ha;Kang, Shin-Hae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.18 no.2
    • /
    • pp.153-162
    • /
    • 1991
  • The present study was undertaken to clarify the role of calcium ion as a factor for the maturation of follicle-enclosed mouse oocytes. Follicles were isolated with two sharp needles under a stereomicroscope from mouse(ICR) ovaries which were treated PMSG 5 IU 45 hours previously. Isolated follicles were cultured for 14-16 hours in an organ culture system at $37^{\circ}C$, 5% $CO_2$ in air and in a 100% humidified incubator by treatment of hCG, EDTA and $^{45}Ca^{++}$. Culture medium was Modified Hank's Balanced Salt Sol. (MHBS) and addition of hCG (human chorionic gonadotropin) was made into two doses level 0.4 IU and 0.8IU from the stock sol. and also $^{45}Ca^{++}$ was treated in the culture medium. To explain the role of calcium, calcium chelating agent EDTA was treated to the culture of the mouse follicle-enclosed oocytes. Two observations were made in the present study; nucleus phase and $^{45}Ca^{++}$ uptake into the oocyte. HCG induced oocyte maturation in the follicle about two folds as much as the control group, whereas there is no difference in oocyte maturation between 0.4 IU and 0.8 IU of hCG. Optimum level of hCG seems to be 0.4 IU/ml in the mouse follicle culture. HCG stimulated $^{45}Ca^{++}$ uptake into the oocyte of the follicles by two folds. $^{45}Ca^{++}$ uptake in the control group is about 2.5 folds in comparison of the EDTA(1.71mM) treated group. However, calcium uptake in the EDTA treated groups tends to increase depending on the decrease of EDTA concentration. These observations suggest that firstly, hCG stimulates maturation of the oocyte of the follicle, secondly, $Ca^{++}$ influx is induced by hCG and thirdly, $Ca^{++}$ influx by the treatment of EDTA decreases as a dosage-dependent process. This $Ca^{++}$ uptake may take place by the changes of permeability which was induced by hCG treatment. That is, $Ca^{++}$ influx may trigger the resumption of oocyte maturation. It is further necessary in the future study how this $Ca^{++}$ uptake is induced by hCG and increases permeability of the follicle and oocyte.

  • PDF

Comparison on marginal fitness and mechanical properties of copings with zirconia block and CAM type (지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young;Kang, Jae-Min
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Purpose: This study provided the basic data for selection the zirconia block and CAM by means of marginal fitness observations, flexural strength test and hardness test. Methods: Three dental zirconia blocks(ABCera, NaturaZ, ST98) and two dental milling machines(CAD/CAM MS, DWX-50) were used in this study. Metal abutment(diameter 10 mm, height 5 mm, inclined angle $3^{\circ}$ taper, 1 mm chamfer margin) was fabricated by Ti customized abutment, and then zirconia copings were fabricated for each ten specimens. Silicone replica technique was used to observe the marginal fitness of cross-sections with a stereomicroscope at ${\times}50$ magnification. The dental zirconia blocks was cut into 10 pieces each having a size of $25mm{\times}5mm{\times}1mm$, and fabricated according to the manufacturer's instructions, and flexural strength was measured using a universal testing machine. For hardness test, a micro Vickers hardness tester was used as it was in the flexural strength test. Statistical analysis was performed by one way ANOVA and post-test was performed by Scheffe test. Results: For marginal fitness of bucco-lingual axial, ZU group($59.7{\pm}10.3{\mu}m$) was the lowest, followed by RA, ZA, ZD, RD, RU. For marginal fitness of mesio-distal axial, ZU group($59.3{\pm}10.2{\mu}m$) was the lowest, followed by RA, ZA, RD, ZD, RU. One-way ANOVA showed statistically significant difference between groups(p<0.05). For flexural strength, ABCera block($718.0{\pm}57.2MPa$) was the highest, followed by NaturaZ, ST98. For hardness, ABCera block($1550.3{\pm}19.8Hv$) was the highest, followed by ST98, NaturaZ. There was no significant difference in flexural strength and hardness between blocks(p>0.05). Conclusion: Based on the results of this study, the type of dental zirconia block did influence the marginal fitness, and all dental zirconia blocks are expected to be suitable for clinical application. The highest flexural strength and hardness were ABCera block, and no statistically significant difference was observed.

A Comparison of Effectiveness of Gracey Curet and Ultrasonic Curet on Subgingival Scaling and Root Planning (치은 연하 치석 제거와 치근면 활택술시 Gracey curet과 Ultrasonic curet의 치석 제거에 효과에 대한 비교 연구)

  • Chung, Suk-Hyung;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.257-269
    • /
    • 2001
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, Gracey curet and Ultrasonic curet were used on single rooted teeth to conduct subgingval scaling and root planning. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth were extracted from 14 patients being treated at department Periodontology Seoul Advantist dental hospital were used. Total 96 area(4 surface per teeth) were evaluated. 12 teeth treated with Gracey curet were used as the control group and the other 12 teeth treated with Ultrasonic curet were examined for experimental group. The 4 surface of the teeth(buccal, mesial, lingual or palatal, distal) were observed through the stereomicroscope and the images of the surface were captured and saved in CCD. The images were displayed on the monitor and the amount of calculus remained was evaluated by overlapping $10{\times}10$ grid pixel screen produced by Microsoft power point. The results evaluated were as follows 1. There was no statistically significant difference in residual calculus and tooth position following scaling and root planning of all group, but statistically significant correlation with residual calculus, probing depth, instruments and tooth surface. 2. There was statistically significant correlation between residual calculus and probing depth, but no statistically significant difference in residual calculus, tooth surface and tooth position on experimental(Ultrasonic curet) group. 3. There was no statistically significant difference in residual calculus according to the pre-treatment pocket depth and tooth position, but statistically significant correlation with tooth surface. The amount of residual calculus increase with mesial, distal, buccal and lingual(or palatal) surface on control(Gracey curet) group. 4. The Gracey showed better results than ultrasonic curet in mesial and distal surface, and there is significant difference. The results demonstrate that ultrasonic curet alone is inadequate for thorough subgingival debridement and suggest that Ultrasonic curet with Gracey curet should be more effective.

  • PDF

Effect of modeling liquid on the shear-bond strength of zirconia core - porcelain veneer (도재 전용액이 지르코니아 코어-도재 비니어의 전단결합강도에 미치는 영향)

  • Choi, Byung-Hwan;Kim, Im-Sun
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose: This study is to evaluate the effect of modeling liquid on the shear-bond strength between zirconia core and veneering ceramic. Methods: Disk-shaped (diameter: 12.0mm; height: 3.0mm) zirconia were randomly divided into six groups according to the surface conditioning method and whether modeling liquid is used or not to be applied (N=60, n=10 per group): group 1-control group with distilled water(ZD); group 2-control group with modeling liquid(ZM); group 3-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$(AD) with distilled water; group 4-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$ with modeling liquid(AM); group 5-liner with distilled water(LD); group $6{\pounds}{\neq}liner$ with modeling liquid(LM). Contact angles were determined by the sessile drop method at room temperature using a contact angle measurement apparatus. The specimens were prepared using dentin veneering ceramics, veneered, 3mm high and 2.8mm in diameter, over the cores. The shear bond strength test was performed in a Shear bond test machine. Load was applied at a cross-head speed of 0.50mm/min until failure. The fractured zirconia surfaces were evaluated by using stereomicroscope (${\times}30$). Collected data were analyzed using SPSS(Statistical Package for Social Sciences) Win 12.0 statistics program. Results: ZD showed the highest contact angle($50.6{\pm}5.4^{\circ}$) and LD showed the lowest value($6.7{\pm}1.3^{\circ}$). Control groups and zirconia liner groups were significantly higher contact angle than liner groups(p<0.05). LD was the highest shear bond strength($43.9{\pm}3.8MPa$) and ZD was the lowest shear bond strength($24.8{\pm}4.9MPa$). Shear bond strengths of control groups and contact angle of liner groups were not significantly different((p>0.05). Liner groups presented adhesive failures. The others groups showed cohesive and adhesive failures. Conclusion: Modeling liquid groups showed lower contact angles and lower shear bond strength compared to those of distilled water groups.

A STUDY ON THE MARGINAL FIDELITY AND THE FRACTURE STRENGTH OF CEROMERS (수종Ceromer의 변연적합도와 파절강도에 관한 비교연구)

  • Chang Hee-Won;Lee Jong-Hyuk;Lim Heon-Song;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.438-452
    • /
    • 2005
  • Statement of problem: The use of Ceromer is increasing in dentistry. But, the research of Ceromer has not been conducted much. Purpose : This study was to evaluate the marginal fidelity and internal adaptation according to marginal position. Materials and Methods: In this study 60 resin crowns were fabricated. The measurements of the marginal fidelity were carried out using stereomicroscope $SZ-40^{(R)}$ (Olympus, Japan) and the measurements of fracture strength were done using Instron $8871^{(R)}$ (Instron Co., U.S.A.) at a cross head speed of 1mm/min. All of the measurements were statistically analyzed by ANOVA test, multiple range test and Weibull analysis. Statistical significance was set in advance at the probability level of less than 0.05. All of the measurements were analyzed with Window $SPSS^{(R)}$ Version 10.0 soft ware for the personal computer. Results : 1. There were no statistical differences of the marginal fidelity between $Targis^{(R)}$ and $Tescera^{(R)}$, but difference between these two and $BelleGlass^{(R)}$ according to materials. 2. There were no statistical differences of the marginal fidelity between no fiber group and fiber group. There were no interactions between each maerial and with/without fiber group in the marginal fidelity 3. There were statistical differences of the fracture strength between $Tescera^{(R)}$ and $BelleGlass^{(R)}$ but no statistical differences of the fracture strength between $Targis^{(R)}$ and $Tescera^{(R)}$, $Targis^{(R)}$ and $BelleGlass^{(R)}$ according to materials. 4 There were statistical differences of the fracture strength between no fiber group and fiber group. There were no interactions between each material and with/without fiber group in the fracture strength. 5. When comparing the fracture surface, no fiber group showed the resin which were fractured at the labial surface and separated from the adhesion surface. In fiber group, the fractures took a place in resin compartments. Conclusion. The marginal fidelity and the fracture strength were clinically acceptable. From these results, $Targis^{(R)}$ and $Tescera^{(R)}$ were superior than $BelleGlass^{(R)}$ in the marginal fidelity But, when applying these resin crowns in clinic, more careful consideration is needed and further study is recommended.

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.

Infection Status with the Metacercariae of Heterophyid Trematode in Mullet and Goby Collected from Western Coastal Areas of Cholla-do, Korea

  • Sohn, Woon-Mok;Moon, Byung-Chul
    • Biomedical Science Letters
    • /
    • v.7 no.1
    • /
    • pp.31-37
    • /
    • 2001
  • The present study was performed to investigate the infection status of heterophyid fluke metacercariae in mullets and gobies collected from some coastal areas of cholla-do. The collected fishes were transferred to the laboratory, artificially digested with pepsin-HCI solution and examined under a stereomicroscope. In 70 mullets examined, the metacercariae of Heterophyes nocens (in 28.6% of fish), Heterophyopsis continua (in 2.9%), Pygidiopsis summa (in 32.9%) and Stictodora spp. (in 14.3%) were detected. The metacercariae of H nocens were detected in mullets from Shinan-gun (in 60.0% of fish), Muan-gun (in 54.4%), Hampyong-gun (in 25.0%) and Yonggwang-gun (in 16.7%). The average metacercarial density per infected fish were 7.6,34, 10 and 5 in each areas. A total of 7 metacercariae of H. continua was detected in only 2 mullets from Hampyong-gun. The metacercariae of p. summa were detected in mullets from Haenam-gun (in 80.0% offish), Muan-gun (in 27.3%), Hampyong-gun (in 16.7%) and Puan-gun (in 100%). The average metacercarial density per infected fish were 350, 14, 5 and 97 in each areas. The metacercariae of Stictodora spp. were detected in mullets from Shinan-gun (in 26.7% offish), Hampyong-gun (in 33.3%) and Puan-gun (in 20.0%). The average metacercarial density per infected fish were 2.8, 18.8 and 2.5 in each areas. In 70 gobies examined, the Metacercariae of H nocens (in 15.7% of fish), H continua (in 47.1%) and Stictodora spp. (in 48.6%) were detected. The metacercariae of H. nocens were detected in gobies from Shinan-gun (in 50.0% of fish) and Yonggwang-gun (in 10.0%). The average metacercarial density per infected fish were 71 and 2 in each areas. The metacercariae of H. continua were detected in gobies from Shinan-gun (in 65.0% of fish), Hampyong-gun (in 70.0%) and Yonggwang-gun (in 60.0%). The average metacercarial density per infected fish were 5.7,6.6 and 3.2 in each areas. The metacercariae of Stictodora spp. were detected in gobies from Shinan-gun (in 80.0% offish), Hampyong-gun (in 70.0%) and Puan-gun (in 40.0%). The average metacercarial density per infected fish were 149,203 and 5.5 in each areas. From the above results, it was confirmed that the mullet and goby from some coastal areas of cholla-do are infected with numerous metacercariae of heterophyid trematodes.

  • PDF

Effects of direct and indirect bonding techniques on bond strength and microleakage after thermocycling (직접 부착법과 간접 부착법이 열순환 후 부착강도와 미세누출에 미치는 영향에 대한 연구)

  • Ozturk, Firat;Babacan, Hasan;Nalcaci, Ruhi;Kustarci, Alper
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.393-401
    • /
    • 2009
  • Objective: The purpose of this study was to compare the shear bond strength (SBS) of brackets and microleakage of a tooth-adhesive-bracket complex bonded with a direct and an indirect bonding technique after thermocycling. Methods: Fifty non-carious human premolars were divided into two equal groups. In the direct bonding group a light-cured adhesive and a primer (Transbond XT) was used. In the indirect-bonding group, a light-cured adhesive (Transbond XT) and chemical-cured primer (Sondhi Rapid Set) were used. After polymerization, the teeth were kept in distilled water for 24 hours and thereafter subjected to thermal cycling (500 cycles). For the microleakage evaluation, 10 teeth from each group were further sealed with nail varnish, stained with 0.5% basic fuchsin for 24 hours, and examined under a stereomicroscope. Fifteen teeth from each group were used for SBS testing with the universal testing machine and adhesive remnant index (ARI) evaluation. Data were analyzed using the Mann-Whitney U test, Chi-square test, and Fisher's exact test. Results: There were no statistical differences on SBS and microleakage between the two bonding techniques. The indirect bonding group had a significantly lower ARI score. Bracket failures were obtained between enamel-resin interfaces. Conclusions: The type of bonding technique did not significantly affect the amount of microleakage and SBS.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).