• Title/Summary/Keyword: Step-up

Search Result 2,375, Processing Time 0.031 seconds

Fabrication and Characteristics of Piezoelectric transformer using PMN-PZT (PMN-PZT 세라믹을 사용한 압전트랜스포머 제작과 특성)

  • 류주현;손은영;류규현;윤현상;정희승
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.13-20
    • /
    • 1997
  • In this paper, the voltage step-up ratio, efficiency and input impedance of the PMN-PZT cert- mic transformer(PT) were investigated for the variation of resonant frequency according to lead resistance. The output voltage and voltage step-up ratio are increased with the the increase of load resistance. The efficiency of PT showed the maxinum value of 91% at R$_{L}$ of 500k$\Omega$X>

  • PDF

I/Q Gain and Phase Imbalances Compensation Algorithm by using Variable Step-size Adaptive Loops at Direct Conversion Receiver (가변 스텝 적응적 루프를 이용한 직접 변환 방식 수신기에서의 이득 및 위상 불일치 보상 알고리즘)

  • 송윤정;나성웅
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1104-1111
    • /
    • 2003
  • The paper presents an algorithm for the compensation of gain and phase imbalances to exist between I-phase and Q-phase signal at direct conversion receiver. We propose a gain and phase imbalances blind equalization compensation algorithm by using variable step-size adaptive loop at direct conversion receiver. The blind equalization schemes have trade-off between convergence speed and jitter effect for the compensation of gain and phase imbalance. We propose the variable step-size adaptive loop method, which varies the loop coefficients according to errors, for recovering these problem. By using variable step-size adaptive loops, we propose to speed up the convergence process and reduce the jitter effect and simulation results show that the algorithm compensates signal loss and speeds up convergence time.

Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm (슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측)

  • Kim, Hyun-Kab;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.109-115
    • /
    • 2016
  • In this paper, In this paper, we use two methods to compare the slim speakers. That way, the diaphragm scan using laser and diaphragm photographed using a thermal imaging camera. Slim speaker has the structure of a flat plate type. Break-up mode by this characteristic is displayed in a larger size. Further, since the installation space is narrow, it has limited moving coil cooling. As a result, the break-up mode slim speakers, a significant impact on quality. In this study, try to connect the break-up mode of the diaphragm, the heat transfer mode of the diaphragm. Experiment for comparison, a two-step. The first step is to measure the divided vibration through the vibration plate scan. The second step measures the diaphragm photographed using a thermal imaging camera. Then, compare the results of both of the same frequency. Thus, comparing the heat transfer pattern and the pattern of break-up mode. Tend to be analysis of break-up mode from the pattern comparison, and document for the optimum design.

Evaluation of Acute Toxicity of Pomace Schisandra chinensis Extracts Using SD-rats (SD-rats를 이용한 오미자박 추출물의 급성경구독성 평가)

  • Seokho, Kim;Bo Ra, Yoo;Young-Suk, Kim;Jong-Min, Lim;Bon-Hwa, Ku;Kyeong Tae, Kwak;Byeong Yeob, Jeon
    • Herbal Formula Science
    • /
    • v.30 no.4
    • /
    • pp.281-291
    • /
    • 2022
  • Objectives : In this study, acute oral toxicity test of pomace Schisandra chinensis extracts was conducted in order to up-cycling to a high value-added industry using by-products discarded in the production process of Schisandra chinensis products and active ingredients such as dibenzocyclooctadiene lignans in Schisandra chinensis. Methods : Pomace Schisandra chinensis extracts were orally administered to SD-rats(female, n=3) without a control group according to the 'OECD guidelines'. After, mortality and clinical signs were observed, and the deceased animals were subjected to an autopsy. In addition, acute oral toxicity test was sequentially performed in step I (300 mg/kg), step II(300 mg/kg), step III(2,000 mg/kg), and step IV(2,000 mg/kg) according to the mortality. Results : There were no abnormalities caused by pomace Schisandra chinensis extracts in step I and step II. However, one animal each died in step III and step IV. In addition, clinical signs(salivation, decrease in food intake, prone position, decrease of locomotor activity, loss of locomotor activity, convulsion, hypothermia, lacrimation, staining around mouth, soiled perineal region, reddish urine, chromaturia, decrease of fecal volume, lying on side, blackish stool, no stool, compound-colored stool, refusal to feed, excitement, hypersensitivity, rigidity, dorsal position, etc.) were observed. But, no clinical signs were observed from 5th day, and experiment animals recovered completely. Conclusions : As a result of this study, pomace Schisandra chinensis extracts may exhibit acute toxicity at concentrations of 2,000 to 5,000 mg/kg, and the GHS classification was designated as 'Category 5'.

EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES (지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향)

  • Hwang, Sung-Yeon;Lee, Kyung-Ha;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.378-384
    • /
    • 2003
  • This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.

Clinical Criteria to Perform the Step through Step Gait with a Cane in Chronic Stroke Patients

  • Kim, Won-Bok;Lee, Jung-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.285-291
    • /
    • 2014
  • PURPOSE: The purpose of this study was to propose clinical criteria to differentiate patients who are able to perform the step-through-step gait pattern in chronic stroke patients. METHODS: Sixty patients with chronic stroke patients participated this study. To differentiate patients who could perform the step-through-step gait pattern, age, gender, and causes of stroke were noted, a Chedoke-McMaster (CM) damage list, Fugl-Meyer (FM) assessment scales and the Berg Balance Scale (BBS) were determined. A 10 meter gait test and Timed Up and Go (TUG) test were conducted to determine the differences in gait speed and dynamic balance between patients walking with or without canes in the step-through-step gait pattern group. RESULTS: There was no significant statistical difference in age, gender, and stroke type between all subjects. There were significant differences in the CM scale for postural and lower extremities, and FM scale for lower extremities and BBS. The dynamic balance ability and gait speed showed significant differences between the subjects in the step-through-step gait pattern with or without a cane during gait. CONCLUSION: CM and FM scales for the lower extremities and postural control, as well as BBS scales, can be used as criteria to differentiate patients who are able to perform the step-through-step gait pattern. These results can also be used to provide beneficial information to patients that are walking with canes.

The Initial Value Setting-Up Method for Extending the Range of the Optimal Step Parameter under LMS Algorithm (LMS 알고리즘에서 최적 매개변수의 선택 폭 확대를 위한 초기치의 설정방법)

  • Cho, Ki-Ryang;An, Hyuk;Choo, Byoung-Yoon;Lee, Chun-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.2
    • /
    • pp.284-292
    • /
    • 2003
  • In this paper, we carried out the numerical examination of the initial value setting-up method to extend the range of optimal step parameter in a adaptive system which is controlled by LMS algorithm. For initial value setting-up methods, the general method which select the initial value randomly and the other method which applies the approximate value obtained from the direct method to initial value, were used. And then, we compared to the ranges of step parameter setting, the convergence speeds of mean-square-error, and the stabilities during the convergence process when the initial values were applied to the optimal directivity synthesis problem. According to the numerical simulation results, the initial value setting-up method by means of the direct method provides wider range for the step parameter, more efficient capability for convergence and stability, and more error correction ability than the general method.

Estimation of volume Ratio according to Step up Filling Method for a Dredged Clay (단계투기법에 의한 준설점토의 체적비 산정)

  • Lee, Song;Kang, Myoung-Chan
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.167-178
    • /
    • 2000
  • An experimental study on step up filling method is carried out to reinforce the Yano method which is widely used to estimate volume ratio and self-weight consolidation settlement in reclamation area. This method considers actual reclamation construction in which dredged clay is continuously filled and rising of deposit height is presented as a result of volume decrease by height rising and self-weight consolidation. It measured the relationship between filling velocity and deposit rising velocity; calculated the total filling height which is needed to achieve the planned final deposit height, and its solid height and the time which is taken to finish the planned final deposit height; and on the basis of these calculated parameters, predicted the self-weight consolidation and volume change ratio in reclamation construction. Yano method is also used to predict the same conditions. 29.8% in self-weight consolidation, 31.1% in volume ratio, 40% in void ratio and water content is underestimated in Yano method compared to step up filling method.

  • PDF

A Study on Step Up-Down AC-DC Converter with DCM-ZVS of High Performance (고성능 DCM-ZVS 스텝 업-다운 AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of IKEEE
    • /
    • v.16 no.4
    • /
    • pp.335-342
    • /
    • 2012
  • This paper is studied on a new DCM-ZVS step up-down AC-DC converter of high performance, that is, high system efficiency and power factor correction (PFC). The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit, and are driven with discontinuous conduction mode (DCM) according to pulse width modulation (PWM). The quasi-resonant circuit uses a step up-down inductor and a loss-less snubber capacitor. The proposed converter with DCM also simplifies the requirement of control circuits and reduces the number of control components. The input AC current waveform in the proposed converter becomes a quasi-sinusoidal waveform proportional to the magnitude of input AC voltage under constant switching frequency. As a result, the proposed converter obtains low switching power loss and high efficiency, and its input power factor is nearly in unity. The validity of the analytical findings is confirmed by some computer simulation results and experimental results.

Virtual DressUp system by using image deformation method (이미지 변형 기법을 이용한 가상 드레스업 시스템)

  • Kim, Na-Ri;Yoon, Jong-Chul;Lee, In-Kwon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • This paper introduces a virtual dress up system, according to user's input model and garment image. At first step, we deform the garment image by using skeleton structures and ARAP method. Next step, sampling the boundary points and find their matching vertices which are used for optimizing the boundary fitting. In 2D rendering of the dress up, they have some unrealistic results, so we reconstruct the garment mesh to the 3D mesh. Rendering from the reconstructed 3D mesh, we can get the final dress up result. We present that our system produce a visually plausible and well-fitted virtual dress up results.

  • PDF