• Title/Summary/Keyword: Step-by-Step Measurement

Search Result 744, Processing Time 0.03 seconds

Time Domain Acoustic Holography by Step-by-step Measurement (단계적 측정법에 의한 시간 영역 음향 홀로그래피)

  • 윤호성;남경욱;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.635-639
    • /
    • 2003
  • When we carry out acoustic holography, step-by-step measurement provides us larger aperture size with same number of microphones. But when we carry out step-by-step measurement, it is blown that sound signal must be stationary. However, when transfer function between input and output signal is time-invariant, we can apply step-by-step measurement to acoustic holography even if sound signal is transient We have to do only some Processing on signals from step-by-step measurements to make the signal data of each step compatiable with other steps. This paper accounts for that processing method.

  • PDF

A two-step approach for variable selection in linear regression with measurement error

  • Song, Jiyeon;Shin, Seung Jun
    • Communications for Statistical Applications and Methods
    • /
    • v.26 no.1
    • /
    • pp.47-55
    • /
    • 2019
  • It is important to identify informative variables in high dimensional data analysis; however, it becomes a challenging task when covariates are contaminated by measurement error due to the bias induced by measurement error. In this article, we present a two-step approach for variable selection in the presence of measurement error. In the first step, we directly select important variables from the contaminated covariates as if there is no measurement error. We then apply, in the following step, orthogonal regression to obtain the unbiased estimates of regression coefficients identified in the previous step. In addition, we propose a modification of the two-step approach to further enhance the variable selection performance. Various simulation studies demonstrate the promising performance of the proposed method.

Strategies Used by Young Children in Weight Measurement Tasks ($4{\sim}6$세 유아의 무게 측정전략 발달에 관한 연구)

  • Rhee, Bo-Young;Kim, Ju-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.7
    • /
    • pp.49-60
    • /
    • 2007
  • The purpose of this study was to analyze the weight measurement tasks according to children's ages and whether 4-to 6-year-old children use proper measurement equipment to measure weight. The study subjects were 105 preschool children: 37,38, and 30 4-, 5-, and 6-year-old children, respectively. The results showed that young children use 3 to 4 strategies. They used a strategy to estimate objects visually on the first step in measurement by direct comparison. On the second step, in measurement by nonstandard unit, they held up objects with one hand or two hands. That is, two strategies were shown in measuring objects with hands in this second step. On the third step, which is measured by standard unit, they used a strategy to choose the equal arm balance out of suggested measurement equipment.

Stability Analysis of Kalman Filter by Orthonormalized Compressed Measurement

  • Hyung Keun Lee;Jang Gyu Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.97-107
    • /
    • 2002
  • In this paper, we propose the concept of orthonormalized compressed measurement for the stability analysis of discrete linear time-varying Kalman filters. Unlike previous studies that deal with the homogeneous portion of Kalman filters, the proposed Lyapunov method directly deals with the stochastically-driven system. The orthonorrmalized compressed measurement provides information on the a priori state estimate of the Kalman filter at the k-th step that is propagated from the a posteriori state estimate at the previous block of time. Since the complex multiple-step propagations of a candidate Lyapunov function with process and measurement noises can be simplified to a one-step Lyapunov propagation by the orthonormalized compressed measurement, a stochastic radius of attraction can be derived that would be impractically difficult to obtain by the conventional multiple-step Lyapunov method.

  • PDF

Development of Back Analysis Program for Total Management Using Observational Method of Earth Retaining Structures under Ground Excavation (지반굴착 흙막이공의 정보화시공 종합관리를 위한 역해석 프로그램 개발)

  • 오정환;조철현;김성재;백영식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10c
    • /
    • pp.103-122
    • /
    • 2001
  • For prediction of ground movement per the excavation step, observational results of ground movement during the construction was very different with prediction during the analysis of design. step because of the uncertainty of the numerical analysis modelling, the soil parameter, and the condition of a construction field, etc. however accuratly numerical analysis method was applied. Therefore, the management system through the construction field measurement should be achieved for grasping the situation during the excavation. Until present, the measurement system restricted by ‘Absolute Value Management system’only analyzing the stability of present step was executed. So, it was difficult situation to expect the prediction of ground movement for the next excavation step. In this situation, it was developed that ‘The Management system TOMAS-EXCAV’ consisted of ‘Absolute value management system’ analyzing the stability of present step and ‘Prediction management system’ expecting the ground movement of next excavation step and analyzing the stability of next excavation step by‘Back Analysis’. TOMAS-EXCAV could be applied to all uncertainty of earth retaining structures analysis by connecting ‘Forward analysis program’ and ‘Back analysis program’ and optimizing the main design variables using SQP-MMFD optimization method through measurement results. The application of TOMAS-EXCAV was confirmed that verifed the three earth retaing construction field by back analysis.

  • PDF

Minimization of Burr Formation in Drilling with Step Drill (구멍가공시 스텝드릴을 이용한 버형성 최소화를 위한 연구)

  • Ko, Sung-Lim;Kim, Jin-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.132-140
    • /
    • 2000
  • In conventional drilling, burr geometry can be changed according to the variation of drill geometry like point angle, rake angle. Step drilling is proposed to minimize the burr formation in drilling operation. The burr formed in first cutting can be removed in second cutting by the edge in step. The burr formed in second cutting by the edge in step can be minimized according to the change of geometry like, step angle and depth. The mechanism in step drilling is analyzed. Some step drills are applied to drilling the input shaft which is used for vehicle steering. To measure the burr formed in drilling, laser and height gage are used.

  • PDF

Numerical analysis on the critical current evaluation and the correction of no-insulation HTS coil

  • Bonghyun Cho;Jiho Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.1
    • /
    • pp.16-20
    • /
    • 2023
  • The International Electrotechnical Commission (IEC) 61788-26:2020 provides guidelines for measuring the critical current of Rare-earth barium copper oxide (REBCO) tapes using two methods: linear ramp and step-hold methods. The critical current measurement criterion, 1 or 0.1 μV/cm of electric field from IEC 61788-26 has been normally applied to REBCO coils or magnets. No-insulation (NI) winding technique has many advantages in aspects of electrical and thermal stability and mechanical integrity. However, the leak current from the NI REBCO coil can cause distortion in critical current measurement due to the characteristic resistance which causes the radial current flow paths. In this paper, we simulated the NI REBCO coil by applying both linear ramp and step-hold methods based on a simplified equivalent circuit model. Using the circuit analysis, we analyzed and evaluated both methods. By using the equivalent circuit model, we can evaluate the critical current of the NI REBCO coil, resulting in an estimation error within 0.1%. We also evaluate the accuracy of critical current measurement using both the linear ramp and step-hold methods. The accuracy of the linear ramp method is influenced by the inductive voltage, whereas the accuracy of the step-hold method depends on the duration of the hold-time. An adequate hold time, typically 5 to 10 times the time constant (τ), makes the step-hold method more accurate than the linear ramp method.

The control & measurement of DC/STEP motor device using the computer (PC를 이용한 직류/스탭모터 장치의 제어.계측)

  • Son, Jun-Hyug;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2206-2208
    • /
    • 2002
  • In this paper, using the communication port between PC(Personal Computer) and DC/STEP MOTOR DEVICE that movement and measurement of motor. Communication port used serial port and movement order transmits by communication port. Consequence of motor device movement displays to tile DC/STEP MOTOR DEVICE APPLICATION. This connection is using the serial port instead of parallel port faster than response time And this application is easier than existing application.

  • PDF

Measurement of Step Difference using Digital Holography of ITO Thin Film Fabricated by Sputtering Method (스퍼터링 공법으로 제작한 ITO 박막의 디지털 홀로그래피를 이용한 단차에 대한 측정)

  • Jung, Hyun Il;Shin, Ju Yeop;Park, Jong Hyun;Jung, Hyunchul;Kim, Kyeong-suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.84-89
    • /
    • 2021
  • Indium tin oxide (ITO) transparent electrodes, which are used to manufacture organic light-emitting diodes, are used in light-emitting surface electrodes of display EL panels such as cell phones and TVs, liquid crystal panels, transparent switches, and plane heating elements. ITO is a major component that consists of indium and tin and is advantageous in terms of obtaining sheet resistance and light transmittance in a thin film. However, the optical performance of devices decreases with an increase in its thickness. A digital holography system was constructed and measured for the step measurement of the ITO thin film, and the reliability of the technique was verified by comparing the FE-SEM measurement results. The error rate of the step difference measurement was within ±5%. This result demonstrated that this technique is useful for applications in advanced MEMS and NEMS industrial fields.

A Study on Measurement of Repetitive Work using Digital Image Processing (영상처리를 이용한 반복적 작업의 측정에 관한 연구)

  • Lee, Jeong-Cheol;Sim, Eok-Su;Kim, Nam-Joo;Park, Chan-Kwon;Park, Jin-Woo
    • IE interfaces
    • /
    • v.14 no.1
    • /
    • pp.95-105
    • /
    • 2001
  • Previous work measurement methods need much time and effort of time study analysts because they have to measure required time through direct observations. In this study, we propose a method which efficiently measures standard times without involvement of human analysts using digital image processing techniques. This method consists of two main steps: motion representation step and cycle segmentation step. In motion representation step, we first detect the motion of any object distinct from its background by differencing two consecutive images separated by a constant time interval. The images thus obtained then pass through an edge detector filter. Finally, the mean values of coordinates of significant pixels of the edge image are obtained. Through these processes, the motions of the observed worker are represented by two time series data of worker location in horizontal and vertical axes. In the second step, called the cycle segmentation step, we extract the frames which have maximum or minimum coordinates in one cycle and store them in a stack, and calculate each cycle time using these frames. In this step we also consider methods on how to detect work delays due to unexpected events such as operator's escapement from the work area, or interruptions. To condude, the experimental results show that the proposed method is very cost-effective and useful for measuring time standards for various work environment.

  • PDF