• 제목/요약/키워드: Step-Down Method

검색결과 181건 처리시간 0.027초

Balanced Force와 Step-Back 근관성형후 치근단 폐쇄효과의 비교연구 (A COMPARISON OF APICAL SEAL FOLLOWING "STEP-DOWN/BALANCED FORCE" AND "STEP-DOWN/STEP-BACK" ROOT CANAL SHAPING)

  • 이윤희;김종화;손호현;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.780-788
    • /
    • 1995
  • The purpose of this study was to compare the apical seal following root canal shaping by different methods. From fourty extracted mandibular 1st and 2nd molars, fourty mesial roots whose canals have some degree of curvature were selected. The mesiobuccal root portion including mesiobuccal portion of a crown was sectioned in each molar. After access cavity preparation for the mesiobuccal canal, working length was determined with # 10 K-file. The sectioned roots were implanted in acrylic resin block and randomly divided into four groups. The canals of group I were shaped by step-down/balanced force, group II by stepdown/step-back, group III by step-back and group IV by conventional method. All of the shaped canals were obturated by Thermafil method and access cavities were filled with IRM. The roots were removed from acrylic resin block and placed in 100 % humidity for 7days. Except the root surfaces of apical 2mm, the root surfaces were nail-varnished 3 times. After the roots were placed in 700 torr vacuum pressure for 15 minutes, they were immersed in 2% methylene blue solution for 4 days. Nail varnishes were removed with acetone. After that, the roots were decalcified in 5 % nitric acid and dehydrated with alcohol series. Transparent specimens were made by methyl salicylate and the quality of apical seal was assessed by measuring the leakage linearly. The results were as follows. 1. The leakage in canals shaped by step-down/balanced force method was significantly less than that in canals shaped by step-back method(P<0.05) and was less but not statistically than that in canals shaped by step-down/step-back method (P>0.05). 2. The leakage in canals shaped by step-down/step-back method was less than that in canals shaped by step-back method, but there was no statistical significance(P>0.05). 3. The leakage in canals shaped by conventional method was significantly more than that in canals shaped by step-down/balanced force, step-down/step-back and step-back method (P<0.05).

  • PDF

적층형 Ring-dot type 압전변압기의 변압특성 (Transformation Characteristics of Multi layed Ring-dot type Piezo Transformer)

  • 정현호;박태곤;김명호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.671-674
    • /
    • 2004
  • This paper presents design and analysis of multi-layered ring-dot type piezoelectric transformer. These transformers are useful for step up and step down. The transformers consist of disk type multi-layered piezoelectric ceramic plates. The finite element method(FEM) was used for analysis transformer. Vibration mode, electric field and equivalent elastic strain of piezoelectric transformer were simulated by changing frequency. As results, the strain was distributed in isolation part entirely. We can get the operated in step up transformer when the inner side electrode using by input parts. Also we can get the step down transformers using by input Part as outer side electrode. The step up ratio and step down ratio was increased by decreasing inner side electrode. The resonance frequency was increased by increasing inner side electrode when the transformer was operated in step down transformer. But the step up one was decreased. From these results, we can expect to multi-layered ring-dot type piezo transformers as step up and step down transformers.

  • PDF

절연형 이중 강압 직류-직류 컨버터의 동특성 해석 및 제어회로 설계 (Dynamic Analysis and Control Circuit Design of Isolated Double Step-Down DC-DC Converter)

  • 하헌철;김한상;최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.229-230
    • /
    • 2015
  • This paper presents practical details about control-loop design and dynamic analysis for a voltage-mode controlled isolated double step-down DC-DC converter. Graphical loop gain method is used to design the feedback compensation and analyze the closed-loop performance of isolated double step-down DC-DC converter. The results of the control design and closed-loop analysis are validated by experiments on a prototype converter.

  • PDF

하향식 다단 압력 그라우팅 방법의 주입특성에 대한 연구 (A Study on the Grouting Characteristics of Top-down Multi-step Pressure Grouting Method)

  • 이홍성;이승호
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.201-209
    • /
    • 2019
  • 국내 사면 및 터널에서 주로 적용되고 있는 다단 압력을 이용한 그라우팅 방법들은 천공 후 지중에서 지표 방향으로 스텝주입을 하는 상향식 다단압력 그라우팅 방법이며 다수의 연구결과와 축척된 시공실적을 토대로 현재 여러 현장에서 적용되고 있다. 국내에서 하향식 다단압력 그라우팅 방법의 연구결과는 미미한 실정이다. 본 논문에서는 토조시험과 현장시험을 통해 기존 상향식 다단압력 그라우팅 방법과 지표부에서부터 주입을 실시하는 하향식 다단압력 그라우팅 방법의 주입효과를 비교 분석하였다. 토조 시험 결과 하향식 다단압력 그라우팅 방법의 경우 상향식 다단압력 그라우팅 방법에 비해 구근체의 부피는 약 24% 증가하는 것으로 나타났다. 현장시험 결과 하향식 다단 압력 그라우팅 방법이 상향식 다단 압력 그라우팅 방법에 비해 주입 범위가 넓고 면적당 주입 밀집도가 높은 것으로 확인되었다.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

교류쵸퍼를 사용한 3상 강압형 전압제어장치 (A 3-phase step-down voltage regulator using AC choppers)

  • 류홍제;김종수;임근희;김득수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1075-1077
    • /
    • 2002
  • This paper describes a three-phase step-down AC voltage regulator using AC chopper and auxiliary transformer which is series connected with main input. It has many advantages such as fast voltage control, high efficiency and low THD. The operation principle and PWM method of the proposed regulator are described. Experimental results show that it can be used as step-down AC voltage regulator for power saving purpose very efficiently.

  • PDF

경방향 확장 진동모드를 이용한 강압용 압전변압기의 특성에 관한 연구 (A Study on Characteristics of Step-down Piezoelectric Transformer Using Contour Extended Vibration Mode)

  • 이원재;민복기;송재성;정현호;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.638-641
    • /
    • 2002
  • This paper presents design and construct of flat type step-down piezoelectric transformer for the application to AC-adapters. This piezoelectric transformer operated in resonance vibration mode. In this paper, Finite element method(FEM) was used for analysis piezoelectric transformers. Vibration mode and electric field of piezoelectric transformer at resonance frequency were simulated. Using this simulation, we manufactured flat type piezoelecric transformer and measured its output characteristics. As results, output power was linearly increased by increasing input power at resonance frequency. And it was found that the transformer exhibited an output power of 11.4[W] at 60[V] input voltage. From these results, we expect that this piezoelecric transformer can be applied to AC adapters.

  • PDF

온칩된 커패시터 채배기법 적용 보상회로를 갖는 DC to DC 벅 변환기 설계 (Design of a Step-Down DC-DC converter with On-chip Capacitor multiplyed Compensation circuit)

  • 박승찬;임동균;윤광섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.537-538
    • /
    • 2008
  • A step-down DC-DC converter with On-chip Compensation for battery-operated portable electronic devices which are designed in 0.18um CMOS standard process. In an effort to improve low load efficiency, this paper proposes the PFM (Pulse Frequency modulation) voltage mode 1MHz switching frequency step-down DC-DC converter with on-chip compensation. Capacitor multiplier method can minimize error amplifier compensation block size by 20%. It allows the compensation block of DC-DC converter be easily integrated on a chip and occupy less layout area. But capacitor multiplier operation reduces DC-DC converter efficiency. As a result, this converter shows maximum efficiency over 87% for the output voltage of 1.8V (input voltage : 3.3V), maximum load current 500mA, and 0.14% output ripple voltage. The total core chip area is $mm^2$.

  • PDF

부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 제어 (Dynamic Characteristics Control of a Step-down Chopper Using Load current Feed-forward Compensator)

  • 전춘병;전지용;전기영;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.66-69
    • /
    • 2008
  • In this paper, The author present a load current feed-forward compensator by method that improve voltage controller of Step-down Chopper to get stable output voltage to sudden change of load current. To confirm the characteristicsof a presented load current feed -forward compensator compared each transfer function of whole system that load current feed-forward compensator is added with transfer function of whole system that existent voltage controller is included using Mason gains formula in Root locus and Bode diagram. As a result the pole of system is improved, extreme point of the wave and system improves, and size of peak value and phase margin of break frequency in resonance frequency confirmed that is good. Therefore, presented control technique could confirm that reduce influence by perturbation and improves stationary state and dynamic characteristics in output of Step-down Chopper.

  • PDF