• Title/Summary/Keyword: Step over

Search Result 1,669, Processing Time 0.027 seconds

Cross-Spectral Characteristics of Wall Pressure Fluctuations in Flows over a Backward-Facing Step (후향계단 주위의 난류 박리재부착유동에서의 벽압력변동의 통계적 특징)

  • Lee, In-Won;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.280-287
    • /
    • 2000
  • Laboratory measurements were made of wall pressure fluctuations in a separated and reattaching flow over a backward-facing step. An array of 32 microphones along the streamwise direction was utilized. Various statistical properties of pressure fluctuations were scrutinized. The main emphasis was placed on the flow inhomogeneity along the streamwise direction. One point statistics such as the streamwise distribution of rms pressure and autospectra were shown to be generally consistent with other studies. The coherences and wavenumber spectra in the streamwise directions were indicative of the presence of dual modes in pressure; one is the large-scale vortical structure in low frequency and the other is the boundary-layer-like decaying mode in high frequency.

An Enhanced Finite-Settling-Step Direct Torque and Flux Control (FSS-DTFC) for IPMSM Drives

  • Kim, Sehwan;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1367-1374
    • /
    • 2016
  • This paper presents a discrete-time version of voltage and current limited operation using an enhanced direct torque and flux control method for interior permanent magnet synchronous motor (IPMSM) drives. A command voltage vector for airgap torque and stator flux regulation can be uniquely determined by the finite-settling-step direct torque and flux control (FSS-DTFC) algorithm under physical constraints. The proposed command voltage vector trajectories can be developed to achieve the maximum inverter voltage utilization for the discrete-time current limit (DTCL)-based FSS-DTFC. The algorithm can produce adequate results over a number of the potential secondary upsets found in the steady-state current limit (SSCL)-based DTFC. The fast changes in the torque and stator flux linkage improve the dynamic responses significantly over a wide constant-power operating region. The control strategy was evaluated on a 900W IPMSM in both simulations and experiments.

Long Waves Generated by Short Wave Groups over a Step: Governing Equations (계단지형을 지나는 파군에 의한 장파의 생성: 지배방정식)

  • Jo, Yong-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.651-657
    • /
    • 2001
  • The second-order long waves generated by short wave groups propagating over a step are theoretically investigated. The diffraction of short waves is firstly formulated and the governing equations of second-order long waves are then derived by using a multiple-scale perturbation method. It is observed that free and locked long waves are generated and propagated with different velocities.

  • PDF

Analysis of the Control Model of Third Harmonics Injected PWM Inverter in Over Modulation Mode (과변조 영역에서의 제3고조파 주입형 PWM 인버터 제어 모델 분석)

  • 김영렬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.66-73
    • /
    • 2000
  • A new modified command voltage of the third harmonics injected PWM inverter is proposed to control the inverter in overmodulation mode. The third harmonics injected PWM has a extended linear region compared with the sine PWM. But it still has a maximum voltage about 90% compared with the six step inverter. By analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonics injected PWM inverter comparative to six-step inverter continuously in over modulation mode. The simulation results of the inverter-induction motor system shows the validity of this method.

  • PDF

Crashworthiness Characteristic Analysis of Composite Non-step Bus (복합제 초 저상 굴절버스의 충돌 특성 해석)

  • Kim, Yu-Seok;Choi, Jung-Hoon;Cho, Jin-Rae;Lee, Sang-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.756-761
    • /
    • 2007
  • This papered is concerned with the crashworthiness characteristics analysis of the non-step bus when it is crashed or roll-over analysis. Computer simulations is implemented using LS-Dyna explicit code which can effectively analysis dynamic response with the lapse of time. We construct a FEM model of the non-step bus under development according to the safety rules used in Europe for composite non-step buses. The crash energy and absorption rate are evaluated to understand crashworthiness characteristic of the composite non-step bus. Body deformation is also examined whether the survival space is secured for passengers.

  • PDF

Numerical Computation of Laminar Flow over a Backward Facing Step (Beckward Facing Step의 층류 유동 수치계산)

  • Van, Suck-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.150-161
    • /
    • 1993
  • 원초변수를 이용한 Navier-Stokes 방정식의 수치계산기법을 개발하고, 이를 응용하여 backward facing step의 층류 유동을 계산하였다. 직교좌표계에서의 비압축성 Navier-Stokes방정식을 풀기위해 시간과 공간항을 2차 정도의 유한 차분을 사용하여 이산화하였고 비교차격자계를 사용하여 양해법으로 수치 계산하였다. 운동량방정식과 연속방정식으로 부터 유도된 압력방정식(pressure-poisson equation)을 이용하여 무발산 조건을 만족시켰ㄲ다. Backward facing step의 층류 유동을 100.$\leq$R$_e$$\leq$1000 범위에 대해서 수치 계산하였으며 실험결과와 잘 일치하는 결과를 구할 수 있었다. 특히 step뒤에서 생기는 박리구간의 길이는 다른 계산결과들보다 실험치에 가까운 값을 얻을 수 있었으며, Re가 600보다 클때는 위쪽 벽에 또 다른 박리 유동이 발생되는 현상이 예측되었다.

  • PDF

FREE SURFACE WAVES OF A TWO-LAYER FLUID OVER A STEP

  • Choi, Jeong-Whan;Whang, Sung-Im
    • Communications of the Korean Mathematical Society
    • /
    • v.15 no.1
    • /
    • pp.173-181
    • /
    • 2000
  • The objective of this paper is to study two dimensional steady gravitational waves on the interface between two immiscible, inviscid and incompressible fluids bounded above by a horizontal rigid boundary and below by a rigid step. A KdV equation for the first order perturbation in an asymptotic expansion can appear. However the coefficient of the KdV theory fails in that case. By a unified asymptotic method, we overcome this difficulty and derive a modified KdV equation with forcing. We find homogeneous steady solutions and present numerical solutions.

  • PDF

유동 전동기 구동을 위한 광역 전류원 콘버어터 2

  • 조규형;박송배
    • 전기의세계
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 1981
  • In the current source inverters (CSI), which are widely used recently in many applications, in order to reduce the harmonic contents in the output line current, twelve-step waveform is synthesized usually by a phase-shifted addition of the output currents of two single CSI's. In this paper a new method of synthesis of the 12-step current waveform is suggested which employes a main and a new auxiliary inverters having lower capacity, and thus is economically advantageous over the conventional scheme. DC-side commutation and energy rebond circuit as described in Part I are also employed in this proposed twelve-step CIS for effective commutation and high reliability. Experimental results are also given in oscillgrams.

  • PDF

Application of Multi-step Undervoltage Load Shedding Schemes to the KEPCO System

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Choy, Young-Do;Kim, Tae-Kyun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.476-484
    • /
    • 2009
  • This paper deals with improvements to the special protection schemes (SPS) which have been applied to the low probability and high impact contingencies in the Korea Electric Power Corporation (KEPCO) system since 2004. Among them, the SPS for voltage instability in the Seoul metropolitan area is considered in this paper, and is a form of event-based undervoltage load shedding with a single-step scheme. Simulation results based upon a recent event that occurred on 765kV lines show that the current setting values of the SPS have to be revised and enhanced. In addition, by applying response-based multi-step undervoltage load shedding (UVLS) schemes to severe contingencies in the system, more effective results than those of the existing single-step SPS can be obtained. Centralized and distributed UVLS schemes are considered in the simulation. ULTC-based load recovery models and over excitation limiters (OXL) for the KEPCO system are also included in the long-term voltage instability studies.