Analysis of the Control Model of Third Harmonics Injected PWM Inverter in Over Modulation Mode

과변조 영역에서의 제3고조파 주입형 PWM 인버터 제어 모델 분석

  • Published : 2000.09.01

Abstract

A new modified command voltage of the third harmonics injected PWM inverter is proposed to control the inverter in overmodulation mode. The third harmonics injected PWM has a extended linear region compared with the sine PWM. But it still has a maximum voltage about 90% compared with the six step inverter. By analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonics injected PWM inverter comparative to six-step inverter continuously in over modulation mode. The simulation results of the inverter-induction motor system shows the validity of this method.

본 논문에셔는 3고초파를 주입한 정현파 PWM 인버터의 과변조 영역에서 인버터를 전형적으로 제어하기 위한 새로운 방법을 제시한다. 정현파 PWM에 3고조파를 삽입하면 단순한 정현파 PWM에 비해 선형영역을 확장할 수 있다. 그러나 이 경우에도 선형영역은 six-step 인버터메 비해 90% 정도가 된다. 따라서 과변조 영역에서 변조지수와 인버터 출력의 기본파 전압의 크기에 대한 관계를 분석함으로써, 과변조 영역에서 기준전압올 보정해 줄 수 있다. 보정된 기준 전압을 명령값으로 사용하게 되므로 반복 계산 없이 3고조파 주입형 정현파 PWM에서 출력전압을 SIX-step에샤의 전압에 이로는 과변조 영역까지 선형적으로 제어가 가능하다. 인버터-유도전동기시스템에 대한 시뮬레이션 결과를 통하여 이를 확인하였다.

Keywords