A Study on the Load Carrying Capacity and Deformation Capacity of the Internal Anchors Welded Cold Formed Concrete Filled Columns (내부앵커형 콘크리트 충전 기둥의 내력 및 변형능력에 관한 연구)

  • Kim, Sun Hee;Yom, Kong Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.347-357
    • /
    • 2013
  • Recently, In recognition of outstanding structural performance the use of Concrete Filled steel Tube(CFT) columns has been increased. Research is ongoing that effective use of cross-sectional because steel strength development and rising prices. In this Lab, suggests new shape by Thin steel plates bent to be L-channel welded to form square steel tube to maximize efficiency of the cross section. In addition, since the rib placed at the center of the tube width acts as an anchor; higher load capacity of buckling is acceptable. we have developed New shape welded built-up square tube for broader usability which were bent to be L-shaped and thin Plate each unit member were welded. In order to apply the new shape built-up square columns, we predicted structure behavior, stress distribution with parameter Width thickness ratio. The experimental results presented in standards and even exceed the b/t of the rib anchors installed in the role due to exert enough strength and deformation to improve performance was favorable.

An Experimental Study on Load Bearing Capacity of Lattice Girder as a Steel Support in Tunnelling (터널 지보재로서 격자지보의 하중지지력에 관한 실험적 연구)

  • 유충식;배규진
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.163-176
    • /
    • 1997
  • It has long been recognized that the H-beam steel rib has many shortcomings when used as a steel support in tunneling. One of the major shortcomings is the shotcrete shadow created behind H-beam flange which eventually reduces the load bearing capacity of shotcrete shell. In many European countries, plate girder as the H-beam steel rib has been replaced by lattice girder which has many advantages over the H-beam steel rib. Successful application of the lattice girder as a steel support requires a thorough investigation on the load bearing capacity of the lattice girder. Therefore, laboratory bending and compression tests were conducted on lattice girders with the aim of investigating the load bearing capacity of the lattice girders. The results of tests show that the load bearing capacity of laIn twice girders is higher than that of H-beams, which indicates that the lattice girder can be effectively used as a support in tunneling.

  • PDF

Bond Performance of Steel to Concrete subjected to Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 이재열;이웅세;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.545-550
    • /
    • 2000
  • Bond between reinforcing bars and the surrounding concrete is supposed to safely transfer load in the design process of reinforced concrete structures. Bar with high relative rib area will be studied further not only static load but also dynamic loading conditions to sustain better performance of bond for reinforced concrete structures under earthquake. To determine the bond behavior of high ribbed bars in beam and column joints under repeated loads, 31 pullout specimens were tested. Bond strength increases as relative rib area increases. Also the effect of relative rib area on bond is larger in cyclic loading than in monotonic loading.

  • PDF

Effective Notch Stress Method for Fatigue Evaluation of Welded Joints in a Steel Bridge Deck

  • Sim, Hyoung-Bo
    • International Journal of Railway
    • /
    • v.5 no.2
    • /
    • pp.89-92
    • /
    • 2012
  • Effective notch stress, as an approach to evaluate the local stress at a notch (weld toe or root), is defined as the total stress assuming linear-elastic material behavior. This method can be effectively used to evaluate the fatigue performance of welded joints. In this study, finite element analysis results using the effective notch stress method were correlated with fatigue test results of rib-to-deck welded joints in a steel orthotropic bridge deck. Effective notch stress approach provided a good correlation with the crack pattern observed in the full-scale fatigue test. A higher effective notch stress at the critical weld toe than at the weld root was consistent with the dominant crack pattern observed at the weld toe during testing. The effective notch stress at the toe on the deck plate was about 80% higher than that on the rib; no cracks at the weld toe on the rib in the testing were observed. Maximum effective notch stress at the weld root occurred on the upper side of the root notch, which indicates that cracks are more likely to propagate into the deck plate, not into the weld metal. This is also consistent with the observed crack pattern in which the crack from the root propagated upward into the deck plate. No such crack pattern, propagating into the weld metal, was observed in the testing.

Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors (ㄱ형 Perfobond 리브 전단연결재의 적용성 평가)

  • Lee, Heung-Su;Chung, Chul-Hun;Kim, Byung-Suk;Kang, Jae-Yoon;Sohn, You-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

A New T Type Perfobond Shear Connector for Composite Action (합성작용을 위한 새로운 Perfobond T형 전단연결재)

  • Chung, Chul-Hun;Kim, Jong-Suk;Shim, Chang-Su;Kim, Kwang-Soo;Jung, Kwang-Hoe;Sim, Chung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.293-296
    • /
    • 2006
  • The results and interpretations of push-out tests on shear connector devices for composite bridges carried out in this study are presented. The devices under investigations are headed studes, perfobond rib, ㄱtype perfobond rib, T- Connector and a new type of shear connector called T type perfobond rib. This new connector is flat steel plate with a number of holes punched through. The results obtained indicate that the T type perfobond rib shear connectors exhibit adequate ductility and substantially higher capacities. Therefore for composite beams utilizing reinforced concrete slabs, the T type perfobond rib shear connectors is a viable alternative to the headed studs.

  • PDF

Performance Evaluation of Perfobond Rib FRP Shear Connectors for Composition between FRP and Concrete (FRP-콘크리트 합성을 위한 퍼포본드 전단 연결재의 성능 평가)

  • Park, Sung-Yong;Cho, Jeong-Rae;Hwang, Hoon-Hee;Cho, Keun-Hee;Baek, Dong-Youl;Kim, Sung-Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.297-300
    • /
    • 2006
  • One of main issues of the FRP-concrete composite member is shear connection between FRP and concrete in order to secure composite behavior of FRP and concrete. To solve this problem, perfobond rib FRP shear connector is introduced for the mechanical shear connection. In this study, experimental study was carried out on the perfobond rib FRP shear connectors in order to develop the effective details of perfobond rib FRP shear connectors. Pull-out test specimens were manufactured with FRP plate with holes embedded in concrete block. Main parameters considered in this study were diameter of holes, ratio of spacing between the centres of holes to the diameter of holes, and thickness of FRP plates. Test results are discussed according to above parameters compared with other empirical expressions for steel perfobond rib connector.

  • PDF

Improvement of the Design and Construction Technique of Orthotropic Steel Deck Bridges : Fatigue Strength of Three Dimensional Full-scaled Model (강바닥판교의 설계 및 시공성 향상방안 : 강바닥판교 3차원 실물 모형체의 피로강도)

  • Oh, Soon Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.1
    • /
    • pp.23-32
    • /
    • 2006
  • This study was conducted to improve the design and construction technique of orthotropic steel-deck bridges. After conducting an F.E.M. analysis of the various rib types of the connection details, static and fatigue tests were conducted, using a three-dimensional, full-scaled, orthotropic, steel-deck-plate model with internal diaphrams, to check the fatigue strength depending on the types of details. The model structure was made of two types of longitudinal ribs: the domestic standard and the European rabbit types. The fatigue strength of the steel-deck system was found to have improved through the installation of an internal diaphram, as no cracks were found on the bottom round part of the scallop with a diaphram. There were no differences between the domestic and the European types of details in terms of strength may be partially influenced by the shape of the scallop and by the installation of an internal diaphram, but it can be improved more significantly according to the quality of the welding that will be done.

A Study on Experiment and Structural Analysis for High-Durability of Orthotropic Steel Deck Bridge (고내구성을 위한 강바닥판교의 실험 및 해석 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.462-467
    • /
    • 2007
  • From the research which it sees verification of the whole interpretation and local interpretation of the durability steel deck bridge a static test and it produces the test body which it sells with character and it executes smallness pul lek detailed interpretation it leads and the appropriate characteristic of smallness pul lek detailed interpretation and to sleep a nominal stress price and it compares it judges it does. The stress quality from each structure region which it follows in load stock location it analyzes and from the hazard which evaluates, the objective region the length rib and the bottom grater weld zone, the length rib and width rib connection department and the width rib with the father it divided. It investigated the stress distribution of the test body from these objective location, FEM interpretation it led and the conduct against each structure state tax it analyzed. General conduct the load stock location the floor plate is located in the center with interpretation price together symmetry characteristic to seem, it cannot be like that it cannot there is one actual test price. Like this reason the length rib and width rib connection actually production even production characteristic security it is a day when it is impossible with the curvature junction department which it blows, it follows in examination body deferment condition and form feed with the fact that it is visible a big difference even with error of some it becomes. Consequently for a data and the research which are more accurate it is judged with the fact that the effort which is prudent will be necessary.

  • PDF