• Title/Summary/Keyword: Steel rebar

Search Result 342, Processing Time 0.025 seconds

Repid Corrosion Test on Reinforcing Steels in Chloride-Penetrating Concrete Structures with Various Crack Patterns (균열특성에 따른 콘크리트 구조물의 염분침투에 관한 실험적 연구)

  • 이상국;정영수;문홍식;안태송;유환구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.345-350
    • /
    • 2001
  • Reinforced concrete is, in general, known as a high durability material due to a strong alkalinity of cement. Probable concrete cracks could incur steel corrosion of RC structures and then could easily deteriorate the concrete durability, which can be fully secured by a systematic quality control for the construction of concrete structures. For the corrosion protection of reinforcing steels in concrete, however, current design specifications of concrete cover depth do not in-depth consider the effect of the cracks as well as the chloride content of RC structures. Therefore, appropriate provisions for concrete cover depth should be coded by considering the influence of concrete cracks on the corrosion of reinforcing steels. The objective of this research is to investigate pertinent cover depth, which can prohibit rebar corrosion, on the basis of experimental corrosion measurements of reinforcing steels on crack characteristics such as the width, depth and frequency of concrete cracks.

  • PDF

Flexural behavior of concrete beams reinforced with aramid fiber reinforced polymer (AFRP) bars

  • Kim, Min Sook;Lee, Young Hak;Kim, Heecheul;Scanlon, Andrew;Lee, Junbok
    • Structural Engineering and Mechanics
    • /
    • v.38 no.4
    • /
    • pp.459-477
    • /
    • 2011
  • Due to the low elastic modulus of FRP, concrete members reinforced with FRP rebars show greater deflections than members reinforced with steel rebars. Deflection is one of the important factors to consider the serviceability of horizontal members. In this study flexural test of AFRP reinforced concrete beams was performed considering reinforcement ratio and compressive strength as parameters. The test results indicated that flexural capacity and stiffness increase in proportion to the reinforcement ratio. The test results were compared with existing proposed equations for the effective moment of inertia including ACI 440. The most of the proposed equations were found to over-estimate the effective moment of inertia while the equation proposed by Bischoff and Scanlon (2007) most accurately predicted the values obtained through actual testing.

Consideration on Bond Behavior of FRP Rebars with Various Surface Treatments and Deformation Shapes (FRP 보강근의 표면처리 및 돌기형상에 따른 부착거동 특성 비교)

  • You, Young-Jun;Park, Ji-Sun;Park, Young-Hwan;Kim, Keung-Hwan;Kim, Hyeong-Yeol;You, Young-Chan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.122-125
    • /
    • 2006
  • This paper presents the comparison of the bond behavior of various FRP rebars. A total of 9 specimens including steel reinforcement were tested through direct pull-out test procedure. The test results have revealed that the bond behavior was affected by the deformation shapes and surface treatments. The newly proposed FRP rebar by KICT showed good bond strength and ductile behavior after failure.

  • PDF

A Study on Probability-based Punching Shear Model of Concrete Slabs Reinforced with FRP rebars (확률기법에 기초한 FRP rebar로 보강된 콘크리트 슬래브의 펀칭전단강도 모델에 대한 고찰)

  • Ju, Min-Kwan;Kim, Gyu-Seon;Kim, Hyun-Joong;Kim, Yong-Jae;Lee, Hyeon-Gi;Sim, Jong-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.151-152
    • /
    • 2010
  • The objective of this study is to propose the new punching shear model for two-way concrete slabs of building structures and bridge decks structures reinforced with FRP or steel rebars. To do this, two evaluating methods are applied here. One is the ratio of test to model and the other is probability analysis with probabilistic uncertainties. In conclusion, it shows that the proposed punching shear model evaluates the tested punching shear strength as conservative with stability and it exhibits better probabilistic characteristics than existing punching shear models.

  • PDF

A Study on Fracture Characteristics of Chemically Prestressed Mortar (화학적 프리스트레스가 도입된 모르타르의 파괴특성에 관한 연구)

  • 안중길;심별;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.828-833
    • /
    • 2003
  • In this paper, a study on fracture characteristics of chemically prestressed mortar with addition of expansive additives was carried out. Uni-axial tension tests with reinforced mortar specimen restrained by embedded reinforcing bar and three point bending tests with notched steel fiber reinforced beams were carried out to verify the characteristics of the cracking behavior, the tension stiffening effect due to bond between rebar and mortar, and fracture characteristic. Tension stiffening curve for the chemically prestressed mortar was obtained from uni-axial tension test. And increased fracture energy due to the chemical prestress was also obtained from bending test and tension softening curve for chemically prestressed mortar was also obtained.

  • PDF

Temperature characteristics of iron and molds in summer apartment conditions (여름철 Apt현장 조건에서의 철근 및 거푸집의 온도특성)

  • Lee, Jea-Hyeon;Moon, Byeong-Yong;Lee, Sang-Un;Lee, Joung-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.17-18
    • /
    • 2016
  • On apartment construction sites in hot weather environments, the high temperature of 30℃ and above and radiation from the sun cause iron and mold temperatures to rise, which lowers worker efficiency and has a negative effect on the deposited concrete. Therefore this study measured the temperature of D10 ~ D16 iron and aluminum items actually used on box frame apartment construction sites currently under construction, in order to give reference information to solve hot weather concrete problems. The temperature measurement results showed that for iron, temperatures rose to around 45℃, and for mold around 58.8℃, calling for safety measures for workers in case of possible burning and other problems.

  • PDF

Underground Parking Lot by ANI Girder(ANgle Integrated Girder) and HCS (ANI Girder(앵글 및 래티스 철근으로 구성된 강조립보)와 HCS(Hollow Core Slab)를 활용한 지하주차장)

  • Choi, Ik-Jun;Jeon, Byong-Kap;Yom, Kyong-Soo;Choi, Sung-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.101-102
    • /
    • 2016
  • Through the story height reducing method, cost saving can be implemented in many aspects. Recently, as one of PC floor system, HCS(Hollow Core Slab) has been applied in many project, and it is proved that it is excellent in productivity, economic efficiency, and workability as well. We developed a new composite beam(ANI Girder) which can be associated with HCS and reinforced with a truss-shape rebar and angle. As a result of actual application on underground parking building with HCS, it is confirmed that this system is effective in workability and story height reducing.

  • PDF

Corrosion Resistance of SD460 Reinforcing Rod by Ceramic Coating (SD460 철근의 세라믹 코팅에 의한 내식성 향상연구)

  • Park, Ki Y.;Lee, Jong K.;Hong, Seok W.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.157-161
    • /
    • 2009
  • The corrosion resistance of reinforcing bar was studied to endure the marine environment during shipment. The red rust on the surface did not damage the adherence in the concrete structures, especially in highly alkaline environment, but made the consumer doubt of the quality. The passivation process by alkalization of the quenching water in the tempcore process failed to endure the long shipping period. The ceramic coating by sol-gel process improved the corrosion resistance without damaging the mechanical properties and adherence between concrete and reinfiorcing bar. Optimal concentration of the coating solution and coating temperature were tested. No additional energy was necessary for the coating process by spraying during cooling process, resulting simplified process and low cost. Salt spray test, cyclic corrosion test and atmospheric test were employed to confirm the resistance. The corrosion rates were presented by rating number and polarization resistance. The coating layer was examined by FIB, XRD and SEM etc.

Tension Test of Hybrid Bars with Carbon and Glass Fibers (탄소와 유리 섬유로 제작된 하이브리드 바의 섬유 배치에 따른 인장성능 실험)

  • You Young Jun;Park Ji-Sun;Park Young-Hwan;You Young-Chan;Kim Keung-Hwan;Kim Hyeong-Yeol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.325-328
    • /
    • 2005
  • Fiber Reinforced Polymers are recognized as the alternative materials for solving the problem due to the excellent corrosion-resistant property, light-weight and higher strength than steel. Glass fiber is superior to other fibers from the economical point of view but the mechanical property is not. For this reason, researches to improve the mechanical property of glass fiber reinforced polymer rebar has been conducted and it emerged as a solution to make the bar as a hybrid type with carbon fibers. This paper presents results of experimental program to investigate the scattering effectiveness of carbon fibers in glass FRP bar.

  • PDF

ADVANCES IN DESIGN AND RESIDUAL LIFE CALCULATION WITH REGARD TO REBAR CORROSION OF REINFORCED CONCRETE

  • C. Andrade;D. Izquierdo;J. Rodriguez;L Ortega
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.15-30
    • /
    • 2005
  • The increasing amount of structures presenting distress due to reinforcement corrosion is urging the establishment of more accurate calculation methods for the service life of concrete structures. In the present paper, a summary of the different approaches is presented that are able to calculate the expected life of new structures, in certain aggressive environments or the residual life of already corroding structures. The methods for the initiation period are based on the proper calculation of the carbonation front or chloride penetration and on the steel corrosion rate. The methods for the residual load-bearing capacity calculations are based in the use of ' indicators ' or in the evaluation of the reduced section and a structural recalculation.

  • PDF