• Title/Summary/Keyword: Steel rebar

Search Result 343, Processing Time 0.029 seconds

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

Investigation of Through-thickness Microstructural Evolution in a 600 MPa-Grade Reinforced Steel Bar Manufactured by Tempcore Process (Tempcore 공정을 통해 제조된 600 MPa급 철근의 두께방향 미세구조 변화 분석)

  • Jiwon Park;Hyunji Kim;Singon Kang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.6
    • /
    • pp.367-373
    • /
    • 2023
  • 600 MPa-grade deformed bar samples were manufactured by conventional hot rolling and subsequent Tempcore heat treatment processes. Considering the short-time water quenching step of the Tempcore process for hot-rolled steel, it is inevitable that the temperature profile of the deformed bar depends strongly on its position throughout the sample thickness. As a result, its microstructure can be easily divided into two regions, the surface and the core regions. The former is expected to have a fresh martensite microstructure under rapid cooling conditions, but self-tempering occurs due to the intense heat flow from the hot core region after the process. The latter is generally known to exhibit a mixed microstructure of ferrite and pearlite due to its slow cooling rate. In this study, detailed microstructural evolutions were examined through the thickness direction. The large variation of the microstructure through the thickness direction in the deformed bar samples is partly due to the easy carbon diffusion from the limited additions of alloying elements.

Using element-embedded rebar model in ANSYS for the study of reinforced and prestressed concrete structures

  • Lazzari, Bruna M.;Filho, Americo Campos;Lazzari, Paula M.;Pacheco, Alexandre R.
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.347-356
    • /
    • 2017
  • ANSYS is a software well accepted by professionals and academics, since it provides a variety of finite elements, material constitutive models, and linear and nonlinear analysis of structures in general. For the concrete material, for instance, the software uses an elastoplastic model with the Willam-Warnke surface of rupture (1975). However, this model is only available for finite elements that do not offer the possibility of use of the element-embedded model for rebars, demanding a much larger amount of elements to discretize structures, making numerical solutions less efficient. This study is, therefore, about the development of a computational model using the Finite Element Method via ANSYS platform for nonlinear analysis of reinforced and prestressed concrete beams under plane stress states. The most significant advantage of this implementation is the possibility of using the element-embedded rebar model in ANSYS with its 2D eight-node quadratic element PLANE183 for discretization of the concrete together with element REINF263 for discretization of rebars, stirrups, and cables, making the solutions faster and more efficient. For representation of the constitutive equations of the steel and the concrete, a proposed model was implemented with the help of the UPF customization tool (User Programmable Features) of ANSYS, where new subroutines written in FORTRAN were attached to the main program. The numerical results are compared with experimental values available in the technical literature to validate the proposed model, with satisfactory results being found.

An Exploratory Study on the Supply Chain Partnership : Focusing on Rebar Manufacturing Firms as Second-tier Suppliers (공급망 파트너십에 관한 탐색적 연구 : 2차 협력업체로서의 철근가공업체를 중심으로)

  • Rhee, Moon-Ki Kyle;Choi, Si-Young;Kim, Tae-Ung
    • Journal of Digital Convergence
    • /
    • v.14 no.8
    • /
    • pp.211-221
    • /
    • 2016
  • The rapid trends toward outsourcing and collaboration have created complex multi-tier supply chains for construction and engineering industries. Working with suppliers and sub-suppliers requires continuous integration activities in order to maximize the performances of the entire supply chain. The purpose of this study is to identify the factors influencing the performances and long-term business relationship of second-tier suppliers in directed sourcing environment. This study proposes the asset specificity, trust, information-sharing and collaboration, as antecedents variables, and collected the survey responses from the second-tier suppliers in rebar manufacturing works. The statistical results indicate that the asset specificity, trust, information-sharing and collaboration have significant influences on the long-term business relationship of rebar manufacturing second-tier suppliers, but trust has no impact on the performances of second-tier suppliers at 5% significance level. Practical implications are also discussed.

Effect of rebar spacing on the behavior of concrete slabs under projectile impact

  • Abbas, Husain;Siddiqui, Nadeem A.;Almusallam, Tarek H.;Abadel, Aref A.;Elsanadedy, Hussein;Al-Salloum, Yousef A.
    • Structural Engineering and Mechanics
    • /
    • v.77 no.3
    • /
    • pp.329-342
    • /
    • 2021
  • In this paper, the effect of different steel bar configurations on the quasi-static punching and impact response of concrete slabs was studied. A total of forty RC square slab specimens were cast in two groups of concrete strengths of 40 and 63 MPa. In each group of twenty specimens, ten specimens were reinforced at the back face (singly reinforced), and the remaining specimens were reinforced on both faces of the slab (doubly reinforced). Two rebar spacing of 25 and 100 mm, with constant reinforcement ratio and effective depth, were used in both singly and doubly reinforced slab specimens. The specimens were tested against the normal impact of cylindrical projectiles of hemispherical nose shape. Slabs were also quasi-statically tested in punching using the same projectile, which was employed for the impact testing. The experimental response illustrates that 25 mm spaced rebars are effective in (i) decreasing the local damage and overall penetration depth, (ii) increasing the absorption of impact energy, and (iii) enhancing the ballistic limit of RC slabs. The ballistic limit was predicted using the quasi-static punching test results of slab specimens showing a strong correlation between the dynamic perforation energy and the energy required for quasi-static perforation of slabs.

An Experimental Study on the Flexural Behavior for the Slabs using the Suspending Deck plate (매닮 데크플레이트를 이용한 슬래브의 휨거동에 관한 연구)

  • Bae, Kyu Woong;Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.25-34
    • /
    • 2013
  • The purpose of the this paper is experimentally to investigate flexural behavior of slabs with suspending the deck plate. The main experimental parameters are the depth and thickness of the deck plate, slab span, rebar and support conditions. Total number of six specimens were tested and manufactured in slabs under vertical load. Based on the results of the test, the flexural behavior for slabs is determined according to the vertical deformation of the slabs, regardless of the main experimental parameters. Bending rebar reinforcement in the rib cross-section specimens can be evaluated significantly higher initial stiffness, crack stiffness and flexural strength. Result of the comparison of the theory value appeared to be fairly well matched to average 1.05.

Evaluation of steel fiber reinforcement effect in segment lining by full scale bending test (실물파괴실험에 의한 세그먼트 라이닝의 강섬유 보강 효과 평가)

  • Lee, Gyu-Phil;Bae, Gyu-Jin;Moon, Do-Young;Kang, Tae-Sung;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.215-223
    • /
    • 2013
  • An experimental research on the possibility of using fiber reinforced concrete precast tunnel segments instead of traditional reinforced concrete(RC) segment has been performed in europe. This solution allows removing the traditional reinforcement with several advantages in terms of quality and cost reduction. Full-scale bending tests were carried out in order to compare the behaviour of the segments under flexural actions on both rebar reinforced concrete and rebar-fiber reinforced elements. The test results showed that the fiber reinforced concrete can substitute the traditional reinforcement; in particular the segment performance is improved by the fiber presence, mainly in terms of crack.

Fire Resistance Performance of Fiber-Cocktail Reinforced 50 MPa High Strength Concrete (섬유혼입된 50 MPa 고강도 콘크리트의 내화성능)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Park, Jong-Heon
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.3
    • /
    • pp.55-60
    • /
    • 2009
  • After applying the fiber cocktail(polypropylene and steel fibers) into the mixture of high strength concrete with a compressive strength of 50 MP, the fire test was carried out on specimens in order to evaluate the fire resistance performance, such as possible explosive spalling, temperature distributions of concrete and rebar. According to an enforcement ordinance, four column specimens were exposed to the fire for 180 minutes based on the standard curve of ISO-834. No explosive spalling has been observed. The required minimum quantity of polypropylene to prevent explosive spalling is more than 0.57 kg per unit concrete volume. The comparing test results from temperature distributions of concrete and rebar has found that the difference of fiber quantity is insignificant.

  • PDF

Service and Ultimate Load Behavior of Bridge Deck Reinforced with GFRP Rebars (GFRP 보강근으로 보강된 교량 바닥판의 성능과 사용성에 관한 실험연구)

  • Yu, Young Jun;Park, Young Hwan;Park, Ji Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.719-727
    • /
    • 2008
  • The tensile and bond performance of GFRP rebar are different from those of conventional steel reinforcement. It requires some studies on concrete members reinforced with GFRP reinforcing bars to apply it to concrete structures. GFRP has some advantages such as high specific strength, low weight, non-corrosive nature, and disadvantage of larger deflection due to the lower modulus of elasticity than that of steel. Bridge deck is a preferred structure to apply FRP rebars due to the increase of flexural capacity by arching action. This paper focuses on the behavior of concrete bridge deck reinforced with newly developed GFRP rebars. A total of three real size bridge deck specimens were made and tested. Main variables are the type of reinforcing bar and reinforcement ratio. Static test was performed with the load of DB-24 level until failure. Test results were compared and analyzed with ultimate load, deflection behavior, crack pattern and width.

Experimental and numerical study on tensile capacity of composite cable-girder anchorage joint

  • Xuefei Shi;Yuzhuo Zhong;Haiying Ma;Ke Hu;Zhiquan Liu;Cheng Zeng
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.215-230
    • /
    • 2023
  • Cable-girder anchorage joint is the critical part of cable-supported bridges. Tensile-plate anchorage (TPA) is one of the most commonly used types of cable-girder anchorage joints in steel girder cable-supported bridges. In recent years, it has been proposed by bridge designers to apply TPA to concrete girder cable-supported bridges to form composite cable-girder anchorage joint (CCGAJ). In this paper, the mechanical performance of CCGAJ under tensile force is studied through experimental and numerical analyses. Firstly, the effects of the external prestressing (EP) and the bearing plate (BP) on the mechanical performance of CCGAJ were investigated through three tests. Then, finite element model was established for parametrical study, and was verified by the experimental results. Then, the effects of shear connector forms, EP, BP, vertical rebar rate, and perforated rebar rate on the tensile capacity of CCGAJ were investigated through numerical analyses. The results show that the tensile capacity of CCGAJ depends on the first row of PR. The failure mode of CCGAJ using headed stud connectors is to form a shear failure surface at the end of the studs while the failure mode using PBLs is similar to the bending of a deep girder. Finally, based on the strut-and-tie model (STM), a calculation method for CCGAJ tensile capacity was proposed, which has a high accuracy and can be used to calculate the tensile capacity of CCGAJ.