• 제목/요약/키워드: Steel for Construction

검색결과 3,425건 처리시간 0.029초

경량기포 콘크리트를 이용한 석재패널 부착 고강도 RC 기둥의 내화 및 폭렬특성 (Properties of the Spalling and Fire Resistance on the High Strength RC Column attached with the Stone Panel Using Lightweight Foamed Concrete)

  • 이동규;백대현;김원기;조용백;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.19-22
    • /
    • 2007
  • This study discussed the prevention of the spalling and improvement of the fire resistance performance how to fill up lightweight foamed concrete on high strength RC column attached with the stone panel. The destructive spalling extremely occur caused by sudden high temperature and increased vapor pressure corresponding to falling the ston panel at all RC column, and the steel bar is exposed. The stone panel fall off about 30 minutes and spalling occur about 70 minutes on Plan RC column, fire endurance paint, and fire endurance mortar, so it can be confirmed that fire endurance paint and mortar, which is used as fire endurance material, are not effective. In the other side, it can be protected from fire about $120{\sim}140$ minutes when the lightweight foamed concrete is used as fire endurance material. For the weight loss after the fire test, plain is 33, fire endurance paint is 37%, and fire endurance mortar s 40.7%. And W/B 60%-3 is 53.4%, 60%-1.5 is 40.1%,65%-3 is 39.4%, and 65%-1.5% is 47.1. Overall, the weight loss of the plain is lower than that of the lightweight foamed concrete.

  • PDF

탄산화가 진행된 기존 RC구조물의 보수 공법 적용 후 탄산화 진행 예측 (Predicting Carbonation Progress of Carbonation Repaired RC Structures Repair)

  • 이형민;이한승
    • 한국건축시공학회지
    • /
    • 제17권3호
    • /
    • pp.235-243
    • /
    • 2017
  • 본 연구에서는 탄산화가 이미 진행된 콘크리트 구조물을 대상으로 촉진 탄산화 실험을 실시하였다. 각 보수재별 탄산화 속도계수를 도출 후 보수후의 탄산화 진행 예측식을 이용하여 탄산화 진행 예측한다. 또한 신뢰성 확보를 위하여 FDM과 FEM 해석을 통한 탄산화 깊이 예측을 비교했다. 그 결과 보수후 탄산화 예측식을 이용하면 탄산화 깊이를 예측할 수 있으며, 초기 $Ca(OH)_2$ 농도 40%로 가정할 때 해석 값과 실험값이 거의 유사함을 알 수 있었다.

섬유시트로 보강된 철근콘크리트 기둥의 압축강도 특성에 관한 실험적 연구 (An Experimental Study on the Compressive Strength Characteristics of Reinforced Concrete Columns Strengthened with Fiber Sheets)

  • 김정섭;최진석;조철희;고송균
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.119-127
    • /
    • 2003
  • Test specimen test was performed using concrete reinforced with fiber sheet and the test variables were based on the kinds of fiber and the number of reinforcement layers. Using steel-concrete reinforced with fiber sheet, compression tests were performed and the test variables were the kinds of fiber, number reinforcement layers and reinforcement layer order. The following results were obtained: 1) It was demonstrated that compressive strength of the test specimen reinforced during test specimen test and member test increased as the number of reinforcement layers increased. 2) It was shown that non-reinforced test, specimen were destroyed during the member tests, but the specimen reinforced with CFS destroyed and the GFS-reinforced specimen and composite reinforced specimen showed ductile destruction. 3) As a result of tests on kinds of reinforcement fiber, it was demonstrated that CFS-reinforced test specimen had higher compressive strength in a 공시체 test. In the member test, 2ply-and 3ply-GFS reinforced specimens except lplied one had higher compressive strength. It was because partial destruction occurred due to the rate of height/section. 4) For layer strength order, compared with test specimen reinforced only with a single reinforced material, test specimen reinforced with CFS and GFS, and test specimen reinforced with CFS first showed better results in compressive strength and ductility judgement.

Experimental investigations on performance of concrete incorporating Precious Slag Balls (PS Balls) as fine aggregates

  • Sharath, S.;Gayana, B.C.;Reddy, Krishna R.;Chandar, K. Ram
    • Advances in concrete construction
    • /
    • 제8권3호
    • /
    • pp.239-246
    • /
    • 2019
  • Substitution of natural fine aggregates with industrial by-products like precious slag balls (PS Balls) offers various advantages like technical, economic and environmental which are very important in the present era of sustainability in construction industry. PS balls are manufactured by subjecting steel slag to slag atomizing Technology (SAT) which imparts them the desirable characteristics of fine aggregates. The main objective of this research paper is to assess the feasibility of producing good quality concrete by using PS balls, to identify the potential benefits by their incorporation and to provide solution for increasing their utilization in concrete applications. The study investigates the effect of PS balls as partial replacement of fine aggregates in various percentages (20%, 40%, 60%, 80% and 100%) on mechanical properties of concrete such as compressive strength, splitting tensile strength, and flexural strength. The optimum mix was found to be at 40% replacement of PS balls with maximum strength of 62.89 MPa at 28 days curing. Permeability of concrete was performed and it resulted in a more durable concrete with replacement of PS balls at 40% and 100% as fine aggregates. These two specific values were considered as optimum replacement is 40% and also the maximum possible replacement is 100%. Scanning electron microscope (SEM) analysis was done and it was found that the PS balls in concrete were unaffected and with optimum percentage of PS balls as fine aggregates in concrete resulted in good strength and less cracks. Hence, it is possible to produce good workable concrete with low water to cement ratio and higher strength concrete by incorporating PS balls.

셀룰로오스 나노섬유를 활용한 해양 방오 코팅제에 관한 기초 연구 (A Basic Study on the Marine Anti-Fouling Coating Using Cellulose Nanofiber)

  • 장낙섭;김태균;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.469-477
    • /
    • 2021
  • 본 연구에서는 해양환경에 노출된 구조물의 내구성과 안전성 저하를 방지하는 셀룰로오스 방오 코팅제에 대한 기본적인 역학 성능을 평가하였다. 셀룰로오스 나노섬유와 AKD 및 폐유리 미분말을 주요 재료로 구성하여 제조하였으며, 접촉각 시험, 건조 시간, 점성 분석, 미세구조 분석을 실시하였다. 셀룰로오스 방오 코팅제를 1회 코팅할 경우 상대적으로 강재 시편에서 높은 소수성능을 발휘하는 것으로 나타났으며, 시멘트 모르타르에서는 AKD 함유량이 증가할수록 접촉각이 증가하는 것이 확인되었다. 3회 코팅시 최대 151.6°의 초소수성을 표면을 확인하였으며, 폐유리 미분말 혼입시 상대적으로 높은 소수성능을 갖는 것이 나타났다. 셀룰로오스와 증류수를 1:1 비율로 제조할 경우 의가소성 유체에 해당하여 코팅제로의 활용에 적합할 것으로 판단되었다.

폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구 (Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT)

  • 구현철;김운학;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.66-73
    • /
    • 2022
  • 동절기 콘크리트 포장체의 블랙아이스 발생위험을 낮추고 동결에 의한손상을 방지할 목적으로 콘크리트의 전도저항성을 활용하여 자기 히팅 콘크리트를 개발하고자 하였다. 이를 위하여 분말형과 액상형 폐CNT와 전도촉진을 위해 폐음극재를 사용하여 강도변화와 온도 발열특성을 평가하고자 하였다. 액상형 폐CNT가 모르타르내에서 분산정도가 효과적이고, 강도저하가 작게 발생하는 것으로 분석되었다. 또한 모르타르에 스틸매쉬, 구리포일과 구리선을 전극으로 적용하여 DC 24 V를 공급하였으며, 폐CNT, 폐음극재과 탄소섬유 혼입율에 따른 온도변화 특성을 평가하였다. 또한 선정된 최적배합으로부터 전극간격에 따른 온도 특성을 평가하여 AC 50 V 까지는 전극간격 100 mm 까지는 충분한 발열 특성을 갖는 것을 확인하였다.

Effect of perlite powder on properties of structural lightweight concrete with perlite aggregate

  • Yan, Gongxing;Al-Mulali, Mohammed Zuhear;Madadi, Amirhossein;Albaijan, Ibrahim;Ali, H. Elhosiny;Algarni, H.;Le, Binh Nguyen;Assilzadeh, Hamid
    • Structural Engineering and Mechanics
    • /
    • 제84권3호
    • /
    • pp.393-411
    • /
    • 2022
  • A high-performance reactive powder concrete (RPC) has been readied alongside river sand, with 1.25 mm particle size when under the condition of 80C steam curing. As a heat and sound insulation, expanded perlite aggregate (EPA) provides economic advantages in building. Concrete containing EPA is examined in terms of cement types (CEM II 32.5R and CEM I 42.5R), doses (0, 2%, 4% and 6%) as well as replacement rates in this research study. The compressive and density of concrete were used in the testing. At the end of the 28-day period, destructive and nondestructive tests were performed on cube specimens of 150 mm150 mm150 mm. The concrete density is not decreased with the addition of more perlite (from 45 to 60 percent), since the enlarged perlite has a very low barrier to crushing. To get a homogenous and fluid concrete mix, longer mixing times for all the mix components are necessary due to the higher amount of perlite. As a result, it is not suggested to use greater volumes of this aggregate in RPC. In the presence of de-icing salt, the lightweight RPC exhibits excellent freeze-thaw resistance (mass is less than 0.2 kg/m2). The addition of perlite strengthens the aggregate-matrix contact, but there is no apparent ITZ. An increased compressive strength was seen in concretes containing expanded perlite powder and steel fibers with good performance.

현장조립이 가능한 무용접 도어프레임 조립방식에 대한 연구 (Research on non-welding door frame assembly method that allows on-site assembly)

  • 이주원;임보혁;이광우;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.155-156
    • /
    • 2023
  • In the case of steel door frames commonly found in general buildings, there are various assembly methods such as rivets, bolts, and welding, but the welding method is generally used. However, this welding joint method has many problems, such as distortion due to heat and damage due to external shock. In particular, when used as a fire door, problems may occur in the event of a fire due to distortion caused by heat from welding and the weak welded joint area. In the case of rivet or welded joints, when moved after assembly, joint loosening due to external shock may occur. Problems may arise where the bonding strength becomes weak. In addition, with the recent increase in high-rise buildings and larger buildings, when assembly is completed and brought to the site, a place is needed to store it, and in addition, there is a problem in that it has to be transported several times in small quantities to the installation site, which is another problem of time and cost loss. This is coming to the fore. In order to fundamentally solve this problem, we have researched and developed a non-welding door frame that can be assembled on site. We have researched and developed three assembly methods: screw-type, insert-type, and protrusion-type. Non-welded door frames are small in size and easy to package, making them advantageous for domestic and overseas exports.

  • PDF

A semi-active mass damping system for low- and mid-rise buildings

  • Lin, Pei-Yang;Lin, Tzu-Kang;Hwang, Jenn-Shin
    • Earthquakes and Structures
    • /
    • 제4권1호
    • /
    • pp.63-84
    • /
    • 2013
  • A semi-active mass damping (SMD) system with magnetorheological (MR) dampers focusing on low- and mid-rise buildings is proposed in this paper. The main purpose of this study is to integrate the reliable characteristics of the traditional tuned mass damper (TMD) and the superior performance of the active mass damper (AMD) to the new system. In addition, the commonly seen solution of deploying dense seismic dampers throughout the structure nowadays to protect the main structure is also expected to switch to the developed SMD system on the roof with a similar reduction performance. In order to demonstrate this concept, a full-size three-story steel building representing a typical mid-rise building was used as the benchmark structure to verify its performance in real life. A numerical model with the interpolation technique integrated was first established to accurately predict the behavior of the MR dampers. The success of the method was proven through a performance test of the designated MR damper used in this research. With the support of the MR damper model, a specific control algorithm using a continuous-optimal control concept was then developed to protect the main structure while the response of the semi-active mass damper is discarded. The theoretical analysis and the experimental verification from a shaking table test both demonstrated the superior mitigation ability of the method. The proposed SMD system has been demonstrated to be readily implemented in practice.

Postbuckling analysis of laminated composite shells under shear loads

  • Jung, Woo-Young;Han, Sung-Cheon;Lee, Won-Hong;Park, Weon-Tae
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.373-394
    • /
    • 2016
  • The postbuckling behavior of laminated composite plates and shells, subjected to various shear loadings, is presented, using a modified 8-ANS method. The finite element, based on a modified first-order shear deformation theory, is further improved by the combined use of assumed natural strain method. We analyze the influence of the shell element with the various location and number of enhanced membrane and shear interpolation. Using the assumed natural strain method with proper interpolation functions, the present shell element generates neither membrane nor shear locking behavior even when full integration is used in the formulation. The effects of various types of lay-ups, materials and number of layers on initial buckling and postbuckling response of the laminated composite plates and shells for various shear loading have been discussed. In addition, the effect of direction of shear load on the postbuckling behavior is studied. Numerical results and comparisons of the present results with those found in the literature for typical benchmark problems involving symmetric cross-ply laminated composites are found to be excellent and show the validity of the developed finite element model. The study is relevant to the simulation of barrels, pipes, wing surfaces, aircrafts, rockets and missile structures subjected to intense complex loading.