Analysis of flow Field in a steam turbine LP/HP Bypass control Valve (증기터빈 Bypass Valve 의 유동장 해석)

  • Choi, Ji-Yong;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.437-440
    • /
    • 2005
  • In the present work, characteristics of the flow in CAGE of a steam turbine LP/HP Bypass control valve for thermal power plant are investigated. The flow field is analyzed numerically by solving steady three-dimensional Reynolds-averaged Navier-Stokes equations. Shear stress transport (SST) model is used as turbulence closure.

  • PDF

Design and Validation Test of Rocket Engine Head Generating High Temperature and High Pressure Steam (고온고압 증기 발생장치의 설계 및 예비운용시험)

  • Park, Jinsoo;Yu, Isang;Oh, Junghwa;Ko, Youngsung;Kim, Kyungseok;Shin, Dongsun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.637-642
    • /
    • 2017
  • In this study, cold flow and combustion tests are conducted and analyzed to validate designed rocket engine head generating high temperature/pressure steam. At first, uni-injector was designed and manufactured, and cold flow test was conducted. Through this, differential pressure that can supply designed flow rate was confirmed. Also, Each injector's spray pattern were confirmed by patternator. Based on cold flow test results, we selected injectors among the candidates and arranged them on engine head, and cold flow and propellant spray tests were conducted. Finally, combustion test was carried out to analyze the flow rate, pressure, combustion efficiency. As a result, validation of rocket engine head for the development of the high temperature and high pressure steam generator has been completed.

  • PDF

Experimental Study of Air-cooled Condensation in Slightly Inclined Circular Tube (경사진 원형관에서의 공냉응축에 관한 실험적 연구)

  • Kim, Dong Eok;Kwon, Tae-Soon;Park, Hyun-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.29-34
    • /
    • 2016
  • In this study, the experimental investigation of air-cooled condensation in slightly inclined circular tubes with and without fins has been conducted. In order to assess the effects of the essential parameters, variable air velocities and steam mass flow rates were given to the test section. The heat transfer performance of air-cooled condensation were dominantly affected by the air velocity, however, the increase of the steam mass flow rate gave relatively weaker effects to total heat transfer capability. And in the experimental cases with the finned tube, the total heat transfer rate of the finned tube was significantly larger than that of the flat tube. From those results, it can be confirmed that the most important parameter for air-cooled condensation heat transfer is the convective heat transfer characteristics of air. Therefore, for the well-designed long-term cooling passive safety system, the consideration of the optimal design of the fin geometry is needed, and the experimental and numerical validations of the heat transfer capability of the finned tube would be required.

Simulation of a Double Effect Double Stage Absorption Heat Pump for Usage of a Low Temperature Waste Heat (저온 폐열 활용을 위한 2중 효용 2단 흡수식 히트펌프 시뮬레이션)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7736-7744
    • /
    • 2015
  • Considering the significant waste of industrial energy, effective use of low temperature waste heat is extremely important. In this study, a heat pump cycle with double effect and double stage was realized, which escalates the hot water temperature from $50^{\circ}C$ to $70^{\circ}C$ using $160^{\circ}C$ high temperature heat source and $17^{\circ}C$ low temperature heat source. The steam generated in the first generator condenses in the first condenser generating steam in the second generator. The steam condenses in the second condenser and is provided to the second evaporator. Part of the water out of the second evaporator is supplied to the first evaporator, which evaporates using low temperature waste heat. The evaporated steam enters the first absorber and the second evaporator. The steam out of the second evaporator is absorbed into the solution at the second absorber. The hot water temperature is raised in the second condenser and in the second absorber. Proper flow rates and UA values, which satisfied temperature lift $20^{\circ}C$ and COP 1.6, were deduced through trior and error. The COP increases as the temperature of the high temperature water increases, hot water temperature decreases and flow rate increases, waste water temperature and flow rate increases, solution circulation rate decreases. On the other hand, the temperature rise of the hot water increases as the temperature of the high temperature water increases, hot water temperature increases and flow rate decreases, waste water temperature and flow rate increases, solution circulation rate increases. In addition, the COP and hot water temperature rise increase as UAs of the heat exchangers increase.

Effect of Condensation on Spray Characteristics of Simplex Swirl Nozzle (응축이 심플렉스 와류 노즐의 분무 특성에 미치는 영향)

  • Koh, Kwang-Uoong;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.107-112
    • /
    • 2001
  • The effect of ambient gas (steam) condensation on swirl spray characteristics were studied experimentally for low subcooling condition of the liquid. The configuration of the liquid(water) sheet and the breakup modes were examined. Also variation of the discharge coefficient, breakup length, local and the cross-sectional area-averaged SMD of droplets with the liquid flow(injection) rate were obtained. The perforation breakup mode appears dominant with condensation while the aerodynamic wave breakup mode is dominant without condensation(in the air environment). The discharge coefficient, breakup length and the mean drop sizes decrease in a same manner with increasing of the liquid flow rate for both cases(with and without condensation). The condensation effects are insignificant with the discharge coefficient. However, the local and cross-sectional area-averaged SMD are larger and the breakup length becomes shorter in the steam environment. The spray angle predicted from the volumetric flux distribution along the radial direction of the sprays in the steam environment becomes larger with condensation.

  • PDF

Evaluation of CO2 desorption efficiency of scrubber absorption system in Liquor Plant (주류공정 내 흡수시스템 CO2 탈리 효율 평가)

  • Park, Il-Gun;Park, Hyung-June;Lee, June-Hyung;Kim, Heung-Rae;Lee, Ju-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.173-182
    • /
    • 2020
  • In this study, amino acid salt absorbents were applied to remove and capture high concentrations of CO2 in liquor factories and regeneration performance was confirmed. In order to evaluate the effective treatment of the desorption process, two methods(Hot plate and Steam) were compared at the laboratory scale. As a result, hot plate and Steam. Hot plate methods regeneration efficiency was about 10% and Steam methods was about 60%. The Steam-Tower condition was evaluated by installing a 100㎥/min flow rate scrubber absorption system in the liquor factory. As a result, it was established that the absorbent flow rate was below 4L/min and the steam temperature was above 160℃. Finally regeneration performance was confirmed as 85.5%.

Effects of Gap between Tube and Support Plate on the Steam Generator Tube Wear (증기발생기 세관과 지지대 간극이 세관 마모에 미치는 영향)

  • Park, Chi-Yong;Lee, Yong-Son;Boo, Myung-Hwan;Kim, Tae-Ryong;Kim, Tae-Soon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.302-307
    • /
    • 2004
  • The major flow-induced vibration mechanisms such as fluid-elastic and turbulence excitation can cause the various types of wear of the steam generator tubes in unclear power plant. It is generally accepted that the tube wear due to vibration is affected by the presence of gap clearance between tube and support plate. Connors showed that the tube wear depth could be estimated by using the relationship between wear volume and sliding distance for contact time. Au-Yang predicted the wear depth by using the nonlinear characteristics of normal work rate to contact time. In this study the effect of gap size on the steam generator tubes wear is analyzed by deriving the wear depth versus normal work rate relationship from these previous results.

  • PDF

Modeling of Steam Injection Heater for Fresh Water Generator (조수기용 증기분사 열교환기에 대한 모델링)

  • Hong, Cheol-Hyun;Lee, Euk-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.877-885
    • /
    • 2008
  • Steam injection heater is the most widely used method for fresh water generator throughout industry. This method is often chosen because of its simplicity. The steam bubbles condense and give up their heat to the surrounding liquid. Experimental study on steam injection heater has been performed in order to find the effect of major parameter. And conservation equation and Bernoulli obstruction theory are used for numerical simulation model of vapor flow-rate. Qualitative comparisons between simulations and measurements show a good agreement and the simulation models are thereby verified.

Development of a Water Droplet Erosion Model for Large Steam Turbine Blades

  • Lee, Byeong-Eun;Riu, Kap-Jong;Shin, Se-Hyun;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.114-121
    • /
    • 2003
  • Water droplet erosion is one of major concerns in the design of modern large fossil steam turbines because it causes serious operational problems such as performance degradation and reduction of service life. A new erosion model has been developed in the present study for the prediction of water droplet erosion of rotor blades operated in wet steam conditions. The major four erosion parameter : impact velocity, impacting droplet flow rate, droplet size and hardness of target are involved in the model so that it can also be used for engineering purpose at the design stage of rotor blades. Comparison of the predicted erosion rate with the measured data obtained from the practical steam turbine operated for more than 90,000 hours shows good agreement.

Methane-Steam Reforming Simulation for a High Temperature Solar Chemical Reactor (고온 태양열 화학 반응기에서의 메탄-수증기 개질반응 시뮬레이션)

  • Ko, Jo-Han;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Steam reforming of methane in the high temperature solar chemical reactor bas advantage in its heating method. Using concentrated solar energy as a heating source of the reforming reaction can reduce the $CO_2$ emission by 20% compared to hydrocarbon fuel. In this paper, the simulation result of methane-steam reforming on a high temperature solar chemical reactor(SCR) using Fluent 6.3.26 is presented. The high temperature SCR is designed for the Inha Dish-1, a Dish type solar concentrator installed in Songdo city. Basic SCR performance factors are referred to the former researches of the same laboratory. Inside the SCR porous metal is used for a receiver/reactor. The porous metal is carved like a dome shape on the incident side to increase the heat transfer. Also, ring-disc set of baffle is inserted in the porous metal region to increase the path length. Numerical and physical models are also used from the former researches. Methane and steam is mixed with the same mole fraction and injected into the SCR. The simulation is performed for a various inlet mass flow rate of the methane-steam mixture gas. The result shows that the average reactor temperature and the conversion rate change appreciably by the inlet mass flow rate of 0.0005 kg/s.