• Title/Summary/Keyword: Steady state line

Search Result 255, Processing Time 0.024 seconds

Multi-Line System with the Switching Rules

  • Ahn, Y.K.
    • Journal of the Korean Statistical Society
    • /
    • v.8 no.1
    • /
    • pp.65-83
    • /
    • 1979
  • The general description concerning the multi-line systems with the switching rules have been presented by Ahn. In this paper we derive some steady state probabilities for three mainly different kinds of systems. We assume that all of the systems are to have poisson input with the finite mean $1/\lambda$ and two servers with the negative exponentional service distribution where each has its own mean $1/u_i$. The notations follow the paper (Ahn, 1979).

  • PDF

Shape Prediction in Eulerian Analysis of Three-Roll-Stand Shape Rolling (Three-Ro II-Stand 형상압연의 오일러리안 해석에서 형상예측)

  • 이용신;나경환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.328-331
    • /
    • 2001
  • Shape changes of a workpiece in an Eulerian Finite Element analysis for the steady state. three-roll-stand shape rolling are modelled. Although an Eulerian analysis has many advantages for the steady state rolling problems, it necessitates an assumption about the unknown shape of the control volume. In almost all cases. the assumed control volume does not match the final shape and the control volume should be updated. This update can be accomplished by performing a free surface correction. The final shape of a material point, which has a spherical shape at the inlet, can be also predicted by integrating a deformation gradient along a stream line. Analyses of three-roll-stand shape rolling is in detail examined.

  • PDF

A Fast off-line Learning Control Approach to Rejection of Periodic Disturbances (주기적인 외란 제거에 있어서 빠른 오프라인 학습 제어 접근 방식)

  • Ha, In-Joong;Jang, Jung-Kook;Park, Jin-Won;Kwon, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.107-109
    • /
    • 2007
  • The recently-developed off-line learning control approaches for the rejection of periodic disturbances utilize the specific property that the learning system tends to oscillate in steady state. Unfortunately, the prior works have not clarified how closely the learning system should approach the steady state to achieve the rejection of periodic disturbances to satisfactory level. In this paper, we address this issue extensively for the class of linear systems. We also attempt to remove the effect of other aperiodic disturbances on the rejection of the periodic disturbances effectively. In fact, the proposed learning control algorithm can provide very fast convergence performance in the presence of aperiodic disturbance. The effectiveness and practicality of our work is demonstrated through mathematical, performance analysis as well as various simulation results.

  • PDF

Non-Data-Aided Spectral-Line Method for Fine Carrier Frequency Synchronization in OFDM Receivers

  • Roh, Heejin;Cheun, Kyungwhoon
    • Journal of Communications and Networks
    • /
    • v.6 no.2
    • /
    • pp.112-122
    • /
    • 2004
  • A nonlinear spectral-line method utilizing the fourth absolute moment of the receiver discrete Fourier transform output is proposed as a non-data-aided fine carrier frequency synchronization algorithm for OFDM receivers. A simple modification of the algorithm resulting in low implementation complexity is also developed. Analytic expressions are derived for the steady-state frequency error variances of the algorithms and verified to be very accurate via computer simulations over AWGN and frequency selective multipath channels. Numerical results show that the proposed algorithms provide reliable and excellent steady-state performance, especially with PSK modulation. Also, the proposed algorithms are insensitive to symbol timing offsets, only requiring a coarse symbol timing recovery.

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

Design of Ratio Control Valve for a Pressure Control Type CVT Using P-Line (P-라인을 이용한 압력제어방식 CVT 변속비제어밸브 설계)

  • 류완식;이용준;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.145-151
    • /
    • 2004
  • In this paper, a pressure control type ratio control valve(RCV) is designed for a metal belt CVT. Steady state and transient characteristics of the pressure control CVT are investigated by simulations and experiments. In addition, P-line is proposed to predict the shift performance. It is found that the bigger the pressure margin, the faster the shift response. It is expected that the P-line can be used in design of the RCV to meet the desired shift performance.

Determination of Critical State Parameters in Sandy Soils from Standard Triaxial Testing (I) : Review and Application (표준삼축시험으로부터 사질토에서의 한계상태정수 결정에 관한 연구 (I) : 고찰 및 적용)

  • 조계춘
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.61-75
    • /
    • 2003
  • Comprehensive review on the determination of critical state parameters in sandy soils from standard triaxial testing was performed to facilitate the application of critical state soil mechanics to the shear behavior of sandy soils. First, semantic differences in literature were clarified, inferring that critical state should be considered as the ultimate state at large deformation. Second, the characteristics of critical state parameters were discussed, and also the uniqueness of critical state line and the sensitivity of quasi-steady state condition were verified in relation to initial state, fabric, loading condition, and drainage condition. Third, as an example, the critical state soil mechanics was applied to evaluate the post-liquefaction shear strength, i.e. the reliable ultimate shear strength in liquified soils, in terms of critical state parameters.

An Experimental Study of Non-Steady State Seepage in the Levee Model by Parallel Water Flow (수평흐름에 의한 제방모형내의 비정상침투에 관한 실험적 연구)

  • Shin, Bang Woong;Lee, Bong Jik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1253-1263
    • /
    • 1994
  • The stability of the embankment is depended upon the location of seepage line. As the seepage flow occurs in the embankment, the slope of the embankment loses its stability. Of particular interest is the stability following a rapid change of embankment level. The variation of seepage line in the embankment model according to flow velocity was investigated. In addition to this non-steady state flow in embankment by a fluctuation of water level is discussed. The experimental model was construction with slopes of 1 : 2.5 and flow velocity is turned from 60 cm/sec~90 cm/sec. Analysis of the experimental results, the seepage line is influenced by flow velocity and coefficient of permeability.

  • PDF

Static Behavior of Gravelly Soil with State Parameter (상태정수에 따른 자갈질 흙의 정적거동)

  • Heo, Seungbeom;Yoon, Yeowon;Kim, Woosoon;Kim, Jaeyoun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.5-14
    • /
    • 2010
  • Recent researches on the behavior of gravelly soils have been focused mainly on the relative density or on the gravel content. And some researchers presented the liquefaction behavior based on the relative density whereas others based on the gravel content of gravelly soil. However the relative densities vary with gravel content and relative density is not enough to fully express the behavior of gravelly soils. Therefore in this research state parameter which considers void ratio and effective confining pressure is introduced and Steady State Line(SSL) of gravelly soils for various gravel content are determined by undrained triaxial tests in order to express the behavior of gravelly soils. From the research the position of SSL moved downward with gravel content. And the same density of soil showed dense sand behavior or loose sand behavior depending upon the confining pressure. Especially relative density 80% of gravelly soil showed loose sand behavior under high confining pressure. However the gravelly soils with similar state parameters showed similar stress behaviors. It can bee seen that state parameter is useful tool to evaluate undrained behavior of gravelly soils. Also state parameter and undrained strength showed good correlations.

A Fuzzy Logical Optimal Efficiency Control of Permanent Magnet Synchronous Motor (PMSM의 퍼지 로직 최적 효율 제어)

  • Zhou, Guang-Xu;Lee, Dong-Hee;Ahm, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.97-99
    • /
    • 2007
  • This paper presents a fuzzy logical control method to implement an on-line optimum efficiency control for Permanent Magnet Synchronous Motor. This method real-timely adjusts the output voltage of the inverter system to achieve the optimum running efficiency of the whole system. At first, the input power is calculated during the steady state in the process of efficiency optimizing. To exactly estimate the steady state of the system, this section needs check up the speed setting on timely. The second section is to calculate input power of dc-bus. The exact measurement of the voltage and current is the vital point to acquire the input power. The third section is the fuzzy logic control unit, which is the key of the whole drive system. Based on the change of input power of dc-bus and output voltage, the variable of output voltage is gained by the fuzzy logical unit. With the on-line optimizing. the whole system call fulfill the minimum input power of dc-bus on the running state. The experimental result proves that the system applied the adjustable V/f control method and the efficiency-optimizing unit possesses optimum efficiency, and it is a better choice for simple variable speed applications such as fans and pump.

  • PDF