• Title/Summary/Keyword: Stator winding

Search Result 425, Processing Time 0.021 seconds

A Technique for Removing Adjacent Induction Noise Mixed with Partial Discharge Signals of High Voltage Rotating Machines (고압 회전기 부분방전 신호에 혼합된 인접상 유도 잡음 제거 기법)

  • Youn, Young-Woo;Yi, Sang-Hwa;Hwang, Don-Ha;Choo, Young-Bae;Kang, Dong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.335-341
    • /
    • 2009
  • Analysis of the partial discharge signal, a technique to diagnose the stator winding insulation is a key function for the diagnosis of high voltage rotating machines and requires high precision. To satisfy this requirement, various denoising techniques such as filtering and differential methods were proposed. However, these techniques can not eliminate a adjacent induction noise that decreases reliability of the diagnosis. A simple novel denoising algorithm, therefore, is proposed for removing the adjacent induction noise in this paper. The algorithm shows good performance in the real partial discharge signals measured by 13kV class capacitive couplers installed at hydro-generator in Dae-cheong Dam.

Aging Diagnosis of Model Coil of HV Induction Motor Using HFPD and Neural Networks (HFPD 및 신경회로망을 이용한 고압 유도전동기 모델코일 열화진단)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.361-367
    • /
    • 2002
  • Many failures in high voltage equipment are preceded by partial discharge activity. In this paper deals with the application of the high frequency partial discharge measurement technique in motorette. HFPD measurement is very effective method to detect the PD occurred in motorette which is the called name of test specimen for accelerating test of stator winding[1] In this study, CT type HFPD sensor is used to detect the partial discharges and a measured HFPD pattern is analyzed by fractal mathematics. The neural network algorithm is used to pattern recognition and ageing diagnosis. As a result of this study, the fractal dimensions are increased along to applied voltage and HFPD pattern recognition using neural network shown excellent recognition rate. Also, the ageing diagnosis of motorette has been Possible.

Parameter Measurement and Dynamic Performance Estimation of Synchronous Reluctance Motor Considering Iron Loss (철손을 고려한 자기저항 동기전동기의 정수 측정 및 동특성 예측)

  • Lee, J.S.;Hong, J.P.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.58-60
    • /
    • 1999
  • This paper presents dynamic performance prediction using Matlab / simulink after parameter estimation of synchronous reluctance motor considering iron loss. Test motor is 3 phase SynRM with the segmental rotor, rating power is 0.175KW. Experiment equipment is consists of testing motor, dynamometer, vector invertor dynamocontroller, and power analyser. The stator iron loss and rotor iron loss are modelled by additional windings on three-phase winding axis. These windings are transformed into d-q axis, and are represented as equivalent eddy current windings. P-Q circle diagram method and single phase standstill method are used to measure motor parameters considering iron loss.

  • PDF

A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter (IGBT 인버터 구동 저압 유도전동기의 절연특성 연구)

  • Hwang, D.H.;Park, D.Y.;Kim, Y.J.;Koo, J.Y.;Park, T.I.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties (견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구)

  • Wang, Jong-Bae;Byun, Yoon-Sub;Baek, Jong-Hyen;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

Analysis of Voltage Distribution in the Stator Winding of Low-Voltage Induction Motor driven by IGBT PWM Inverter (IGBT 인버터 구동 저압 유도전동기 고정자 권선의 과도전압 해석)

  • Kim, C.H.;Lee, Y.H.;An, H.J.;Hwang, D.H.;Park, D.Y.;Huh, I.G.;Choi, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.690-692
    • /
    • 2000
  • In this paper voltage distribution in the windings of an inverter fed induction motor is studied. High frequency parameters of the induction motor are calculated using finite element analysis. With these parameters. a high frequency equivalent circuit of the inverter-cable-motor is formed. The transient analysis is performed using ATP-EMTP package to estimate the voltage distribution in the motor windings.

  • PDF

Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage (불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • 김종겸;박영진;정종호;이은웅
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.6
    • /
    • pp.372-379
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Rotating machines operating on an unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on steady states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor (prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구)

  • Lwin, K.S.;Shin, D.H.;Lim, K.J.;Kong, T.S.;Kim, H.D.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF

Analysis on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by Multi level inverter (멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감을 위한 RC필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul;Kim, Young-Sung;Lee, Yang-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.399-403
    • /
    • 2005
  • In this paper, we analyze on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of switching surge appears more serious in high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the RC filter connected to the motor terminals greatly reduces the transient voltage stress md ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

  • PDF

Staring Characteristic of Wound Rotor Induction Motor by New Winding Method (새로운 권선법에 의한 권선형 유도전동기의 기동특성)

  • 강만원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.27-31
    • /
    • 1999
  • This paper covers starting characteristics and design of wound motor induction rmtor can used to double excited induction mootor. They are employing in many electrical equiprrent system of industrial field The stator is satre as that of conventional induction motor. But rotor was rewind with new style, as result both of starting torque and operating efficiency could be high, But starting current could be small. Could obtain the satre result as that of conventional induction rmtor with external resistance on the rotor. The structure could be simple, system cost could be low and the maintanence free, Because of no slip rings, no brushes and no external resistance.stance.

  • PDF