• 제목/요약/키워드: Static pressure

검색결과 1,378건 처리시간 0.027초

홉킨슨 압력봉법을 이용한 Fe-6.5wt.%Si 합금의 고변형률속도 거동 (High-Strain-Rate Deformation of Fe-6.5wt.%Si Alloys using a Split Hopkinson Pressure Bar Technique)

  • 윤영기;윤희석
    • 대한기계학회논문집A
    • /
    • 제25권7호
    • /
    • pp.1073-1081
    • /
    • 2001
  • Many researches have published numerous papers about the high-strain-rate obtained from Split Hopkinson Pressure Bar(SHPB) tests. And 6.5wt%Si steel is widely known as an excellent magnetic material because its magnetostriction is nearly zero. Single crystals are prepared by the Floating Zone(FZ) method, which melts the alloy by the use of a high temperature electron beam in a pure argon gas condition. In this paper, the fracture behavior of the poly crystals and single crystals (DO$_3$phase) of Fe-6.5wt%Si alloy by SHPB test is observed. The comparison of high-strain-rate results with static results was done. Obtained main results are as follows: (1) Fe-6.5wt%Si alloy has higher strength at high-strain-rate tensile. SHPB results of polycrystal are twice as high as static results. (2) From the fractography, the cleavage steps are remarkably reduced in the SHPB test compared with the static test.

리어가이더 곡률반경에 따른 룸에어콘용 관류홴의 공력성능에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Curvature Radius of a Rear-Guider for a Room Air-Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.36-44
    • /
    • 2013
  • The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. Also, these factors are given to the various diameter ratio between a basic circle and a impeller. The static pressure and the flowrate of a cross-flow fan were measured with a fan-tester. It could be found that the useful design factors with a good aerodynamic performance exist in the certain assembly conditions of an indoor RAC. Therefore, it could be known that a new published patent determining the easy design of an indoor RAC can be applied in a variety of goods.

Change of Balance Ability in Subjects with Pain-Related Temporomandibular Disorders

  • Ja Young Kim;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.321-325
    • /
    • 2022
  • Purpose: Temporomandibular disorder (TMD) is a condition defined as pain and dysfunction of temporomandibular joints and masticatory muscles. Abnormal interconnections between temporomandibular muscles and cervical spine structures can cause the changes of postural alignment and balance ability. The aim of this study was to investigate changes in static balance ability in subjects with painrelated TMD. Methods: This study conducted on 25 subjects with TMD and 25 control subjects with no TMD. Pressure pain thresholds (PPTs) of the masseter and temporalis muscles were measured using a pressure algometer. Static balance ability was assessed during one leg standing using an Inertial Measurement Unit (IMU) sensor. During balance task, the IMU sensors measured motion and transfer movement data for center of mass (COM) motion, ankle sway and hip sway. Results: PPTs of masseter and temporalis muscles were significantly lower in the TMD group than in the control group (p<0.05). One leg standing, hip sway, and COM sway results were significantly greater in the TMD group (p<0.05), but ankle sways were not different between group. Conclusion: We suggest pain-related TMD is positively related to reduced PPTs of masticatory muscles and to static balance ability. These results should be considered together with global body posture when evaluating or treating pain-related TMD.

급수용 감압밸브의 비다이어프램 스템에서 압축스프링에 따른 유량 및 토출압력 효과 (Effects of Flow Rate and Discharge Pressure with Compressing Spring in Non-diaphragm Type Stem of Water Pressure Reducing Valve)

  • 변재욱;김치호;박성환;이명원;강명창
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.103-109
    • /
    • 2019
  • The pressure reducing valve for water is controlled by the load of the compression spring and the force of the fluid acting on the diaphragm of the stem. Repeated upward and downward reciprocation of the pressure-reducing valve stem damages the diaphragm, resulting in leakage. In this study, we designed a stem without a diaphragm and adjusted the stiffness of the compressing spring. In order to select the spring stiffness, springs offering a stiffness of -20%, -10%, 0%, and 10% with respect to the stiffness of the compression spring attached to the existing pressure reducing valve stiffness. A prototype for the pressure reducing valve was fabricated and the pressure change was evaluated for the target static pressure (6 bar) by testing the pressure characteristics after mounting the modified stem and each compression spring. Evaluation of the pressure characteristics was carried out using ASSE 1003 and KS B 6153. In addition, the flow rates were compared by internal flow analysis of the conventional pressure reducing valve and the pressure reducing valve using the modified stems, and the flow analysis was performed using Solidworks flow simulation 2018. The spring stiffness was constantly discharged at the target static pressure of 3.793 kgf/mm, and the flow rate was increased by about 15% compared with the conventional pressure reducing valve.

Difference in the Static Postural Control according to the Subjective Visual Vertical Deviation and Head Orientations

  • Sang Soo Lee;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • 제35권5호
    • /
    • pp.156-161
    • /
    • 2023
  • Purpose: This study examined the effects of subjective visual vertical perception and head orientation on static balance control. Methods: The subjects were 25 young and healthy adults. The vertical perception was measured using a subjective visual vertical (SVV), and the Center of pressure (COP) parameter was analyzed by continuously measuring the movement of the COP to determine the changes in static postural control. The group was divided based on a deviation of 3° in SVV (11 of SVV≥3°, 14 of SVV<3°) and measured with different head orientations: front, up, down, left, and right in the upright and tandem positions, respectively. Results: In the upright position, the SVV≥3° group had significantly larger values for all COP parameters (Sway length, Surface, Delta X, Delta Y, and Average speed) compared to the SVV<3° group (p<0.05). In the tandem stance, only the Ellipse Surface value was significantly larger among the COP parameters in the group with SVV≥3° compared to the group with SVV<3°(p<0.05). In contrast, the other COP parameters were not significantly different (p>0.05). The effects of static balance control on the head orientation were not statistically significant (p>0.05), and the interactions between the subjective vertical perception and head orientation were not significant (p>0.05). Conclusion: These results suggest that pathological deviations in SVV are associated with impaired static balance performance. This study can provide a therapeutic rationale for using visuospatial cognitive feedback training to improve the static balance.

진원형 정수압 베어링의 해석 및 실험적 고찰 (Analysis and Experimental Investigation of Cylindrical Hydrostatic Bearing)

  • 문호지;한동철
    • Tribology and Lubricants
    • /
    • 제6권1호
    • /
    • pp.57-67
    • /
    • 1990
  • For increasing the performance of Machine tools, the improvement of the static and dynamic characteristics of spindle bearing is important. In this paper are the static characteristics, the pressure distribution, friction force and outlet flow rate, and the dynamic characteristics stiffness and damping coefficient, of a cylindrical hydrostatic journal bearing with multi oil pockets are analyzed.

정압비례제어방식을 적용한 정압급수장치의 개발 (Development of a constant pressure feed system using a constant pressure proportional control mode)

  • 김주명;김광열;이건기
    • 한국정보통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.1026-1031
    • /
    • 2003
  • 자동 급수펌프는 압력스위치에 의해 운전 및 정지를 하게 된다. 따라서 수량 증감에 따른 펌프의 빈번한 운전 및 정지로 인해 지속적인 정격 및 정압 운전이 불가능하다. 또한 빈번한 작동으로 인해 지속적으로 일정한 압력을 얻을 수 없으며, 펌프의 소손과 에너지의 낭비가 심한 단점을 가지고 있다. 본 논문에서는 이러한 단점을 해결하고자 급수밸브, 유량센서, 제어장치로 구성되는 정압 급수장치를 설계 제작하였다. 급수밸브는 유출되는 물의 양과 관계없이 항상 일정한 양의 물을 유입하여 펌프의 부하를 줄이는 역할을 한다. 유량센서는 적외선 다이오드를 사용하여 유출되는 물의 양의 측정하며, 제어장치는 8 비트 마이크로프로세서를 이용하여 설계하였으며, 특별한 제어 알고리듬에 의해 펌프의 운전과 정지를 제어하게 하였다. 본 논문에서 개발한 장치는 토출 압력이 일정하게 유지되고 펌프의 작동 및 정지 동작이 부드럽게 이루어지며, 펌프의 지속적인 정압운전이 가능하므로 기존의 단점을 보완하는 장치로 사료된다.

석유화학 플랜트의 배관계 설계기준에 대한 연구 (A Study on Design Criteria of Piping System in Petrochemical Plant)

  • 민선규;최명진
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.192-199
    • /
    • 2002
  • Largely, there are three kinds of the design criteria of piping system in petrochemical plant. The first is on the pipe thickness in accordance with the design pressure of piping system. The second is on the static state evaluation by thermal growth and the other is on the dynamic evaluation by piping vibration. According to the ASME B31.3 code, the internal pressure design thickness fur straight pipe shall be calculated as a code formula. And the static design by thermal displacement is defined 7000 cycles of fatigue life in operating the piping system with a design condition. However, the dynamic design evaluation in comparative with small displacements of high frequencies to the static condition has not established clearly the method, yet. So, this study purposes to present the trial of a proposal of dynamic design criterion on the basis of static design method.

정상인의 자세와 시각 교란에 따른 정적 균형능력의 변화 (Evaluation of Static Balance in Postural Tasks and Visual Cue in Normal Subjects)

  • 서삼기;김수현;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제21권4호
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: This study examined the difference in the static balance ability according to the visual cues and postural tasks in normal subjects. Methods: Thirty participants (12 male, 18 female; mean age $24.63\pm1.43$ years) stood barefoot on a force platform in a one-legged stance, tandem Romberg stance and tandem Romberg with neck extension stance with a visual cue open and closes. The static balance was assessed by the center of pressure (CoP), surface electromyography root mean square (RMS) of the leg muscles according to the stance position. Results: In the CoP tests, the difference in the unit path length and circumference area was affected by the visual cue according to the stance posture (p<0.01). In the RMS tests, the difference in the tibialis anterior and medial gastrocnemius muscle was affected by visual cue in accordance with the stance posture (p<0.01). Conclusion: The visual cue and postural task affect the balance ability in normal subjects. Therefore, this study provides clinical evidence that the balance and postural control can be improved. Therapeutic intervention, such as an obstacle course, and a lower leg muscle performance program with a change in the base of support can affect the balance and postural control.

  • PDF

노인에서 임상적 균형평가 지수들의 유용성 : 힘판을 이용한 균형평가와의 상관관계 (The Usefulness of Clinical Balance Tests in Elderly : Correlation of Balance Evaluation using by Forceplate)

  • 우영근;황수진;이우형
    • PNF and Movement
    • /
    • 제8권1호
    • /
    • pp.67-77
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the usefulness of clinical balance tests through the correlation of balance evaluation using by forceplate in elderly. Methods : Thirty nine healthy elderly subjects (14 males, 25 females) participated in the study. The subjects were evaluated with clinical balance tests [(Berg balance scale (BBS), Functional reach test (FRT), Tinetti's performance oriented mobility assessment (POMA), and one leg standing (OLS)]. Static balance evaluation was assessed by using forceplate. Center of pressure (COP) parameters were obtained using it as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened and closed, (2) uncomfortable standing with eyes opened and closed. After static balance evaluation tested, dynamic balance evaluation was assessed. COP parameters were error distance and area during sine curve trace. COP parameters were movement time, error distance, and maintained time in the circle during COP movement task. Results : Clinical balance tests showed statistically significant correlation between static and dynamic balance evaluations. Among the clinical balance tests, the BBS, POMA, and OLS showed significant correlation with to assess the balance ability of elderly in clinical setting both evaluations. Conclusion : Clinical balance tests can be recommended in clinical setting because of low costs and simplicity.

  • PDF