DOI QR코드

DOI QR Code

Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Curvature Radius of a Rear-Guider for a Room Air-Conditioner

리어가이더 곡률반경에 따른 룸에어콘용 관류홴의 공력성능에 대한 실험적 연구

  • Kim, Jang-Kweon (Department of Power System Engineering, Kunsan National University) ;
  • Oh, Seok-Hyung (School of Mechanical Engineering, Kunsan National University)
  • 김장권 (군산대학교 동력기계시스템공학과) ;
  • 오석형 (군산대학교 기계공학부)
  • Received : 2013.02.07
  • Accepted : 2013.05.29
  • Published : 2013.08.31

Abstract

The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. Also, these factors are given to the various diameter ratio between a basic circle and a impeller. The static pressure and the flowrate of a cross-flow fan were measured with a fan-tester. It could be found that the useful design factors with a good aerodynamic performance exist in the certain assembly conditions of an indoor RAC. Therefore, it could be known that a new published patent determining the easy design of an indoor RAC can be applied in a variety of goods.

Keywords

References

  1. P. Mortier, 1893, "Fan or Blowing Apparatus", U. S. Patent No. 507445.
  2. A. M. Porter and E. Markland, 1970, "A Study of the Cross Flow Fan", J. Mechanical Engineering Science, Vol. 12, No. 6, pp. 421-431. https://doi.org/10.1243/JMES_JOUR_1970_012_071_02
  3. H. Ilberg and W. Z. Sadeh, 1965, "Flow Theory and Performance of Tangential Fans", Proc. Instn. Mech. Engrs., Vol. 180, Part 1, No. 19, pp. 481-491. https://doi.org/10.1243/PIME_PROC_1965_180_034_02
  4. S. Murata and K. Nishihara, 1976, "An Experimental Study of Cross Flow Fan (1st Report, Effects of Housing Geometry on the Fan Performance)", Bulletin of the JSME, Vol. 19, No. 129, pp. 314-321. https://doi.org/10.1299/jsme1958.19.314
  5. L. Preszler and T. Lajos, 1972, "Experiments for the Development of the Tangential Flow Fan", Proc. of the 4th Conference on Fluid Machinery, Budapest, Akademiai Kiado, pp. 1071-1082.
  6. H. Tsurusaki et al., 1993, "Study of Cross-Flow Fan Internal Flow by Flow Visualization (1st Report, Discussion of Measured Results by Particle-Tracking Velocimetry)", Trans. of JSME (Series B), Vol. 59, No. 568, pp. 3743-3748. https://doi.org/10.1299/kikaib.59.3743
  7. A. Toffolo, A. Lazzaretto and A. D. Martegani, 2004, "An Experimental Investigation of the Flow Field Pattern within the Impeller of a Cross-Flow Fan", Experimental Thermal and Fluid Science, Vol. 29, No. 1, pp. 53-64. https://doi.org/10.1016/j.expthermflusci.2004.02.007
  8. S. H. Seo, N. Y. Lee, J. H. Lee, S. W. Chin and K. S. Im, 1995, "A Study of Stabilizer for the Noise Reduction in Room Air Conditioner", Proc. of KSNVE Fall Annual Meeting, pp. 136-141.
  9. H. M. Koo, 1999, "An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner", Trans. of KSME (Part B), Vol. 23, No. 6, pp. 695-702.
  10. J. K. Kim, 1996, "Judging Method of Rear- Guider Shape of Cross-Flow Fan", K. S. Patent No. 107610, November 13. (in Korean)
  11. J. K. Kim, 2005, "Experimental Study on the Aerodynamic Performance Characteristics for Various Design Factors in the Maximum Flowrate range of a Cross-Flow fan", J. of KSPSE, Vol. 9, No. 3, pp. 44-49.
  12. J. K. Kim and K. J. Jeong, 2005, "Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Design Factors of an Indoor Room Air-Conditioner", J. of KSPSE, Vol. 9, No. 3, pp. 33-38.
  13. T. Ikui and M. Inoue, 1988, "Turbo-Blowers and Compressors", Corona Publishing Co., LTD., pp. 293-297.