• Title/Summary/Keyword: Static alignment

Search Result 76, Processing Time 0.022 seconds

A 0.12GHz-1.4GHz DLL-based Clock Generator with a Multiplied 4-phase Clock Using a 0.18um CMOS Process

  • Chi, Hyung-Joon;Lee, Jae-Seung;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.264-269
    • /
    • 2006
  • A $0.12GHz{\sim}1.4GHz$ DLL-based clock generator with the capability of multiplied four phase clock generation was designed using a 0.18um CMOS process. An adaptive bandwidth DLL with a regulated supply delay line was used for a multiphase clock generation and a low jitter. An extra phase detector (PD) in a reference DLL solves the problem of the initial VCDL delay and achieves a fast lock time. Twice multiplied four phase clocks were generated at the outputs of four edge combiners, where the timing alignment was achieved using a coarse lock signal and the 10 multiphase clocks with T/8 time difference. Those four clocks were combined one more time using a static XOR circuit. Therefore the four times multiplication was achieved. With a 1.8V supply, the rms jitter of 2.1ps and the peak-to-peak jitter of 14.4ps were measured at 1.25GHz output. The operating range is $0.12GHz{\sim}1.4GHz$. It consumes 57mW and occupies 450*325um2 of die area.

The Development of PLS-II Storage-ring Girder Systems at PAL (방사광 가속기 PLS-II 저장링 거더 시스템 개발)

  • Kim, Seungnam;Lee, Chaesun;Lee, Honggi;Kim, Kwangwoo;Nam, Sanghun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.690-697
    • /
    • 2013
  • The magnets and vacuum chambers, which are the main facilities of the Pohang light source are installed on the storage-ring girders. System safety and reliability should be taken into account for the precise operating of the main facilities, so vibration analysis is essential to do this. Static and seismic analyses were performed for the design of structure considering safety, and also frequency and response spectrum analyses were performed for the precise alignment. With these results, the effects of surrounding vibration were checked. This paper explains about the design and vibration analysis of girder systems.

Design and Fabrication of Movable Micro-Fersnel Lens on XY-stage (XY-Stage에 의해 정적인 변위를 갖는 미세 프레넬 렌즈(Micro-Fresnel Lens)의 설계 및 제작)

  • Kim, Che-Heung;Ahn, Si-Hong;Lim, Hyung-Taek;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2515-2517
    • /
    • 1998
  • The micro fresnel lens(MFL) was modeled and fabricated on a XY-stage electrostatically driven by comb actuator. The modeled MFL was approximated as a step shape with 4-phase and 4-zone plate. The focal length and diameter of the MFL is 20mm and 912${\mu}m$, respectively. The XY-stage suspending the MFL is designed to generate a large static displacement up to about 20${\mu}m$. On SOI substrates, we first fabricated MFL using the RIE(reactive Ion etching) technology and then patterned and etched bulk silicon to make XY-stage. After the fabrication of all structures on top side of the SOI substrates. $Si_3N_4$ was deposited for passivation of all structures using PECVD(plasma enhanced chemical vapor deposition). All the MFL systems width comb drive actuator were released by KOH etching from the bottom side of the SOI wafer using double-sided alignment technique. In fabrication of MFL, a dry etching conditions is established in order to improve surface roughness and to control the etched depth.

  • PDF

Fabrication and Characterization of a Pressure Sensor using a Pitch-based Carbon Fiber (탄소섬유를 이용한 압력센터 제작 및 특성평가)

  • Park, Chang-Sin;Lee, Dong-Weon;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.417-424
    • /
    • 2007
  • This paper reports fabrication and characterization of a pressure sensor using a pitch-based carbon fiber. Pitch-based carbon fibers have been shown to exhibit the piezoresistive effect, in which the electric resistance of the carbon fiber changes under mechanical deformation. The main structure of pressure sensors was built by performing backside etching on a SOI wafer and creating a suspended square membrane on the front side. An AC electric field which causes dielectrophoresis was used for the alignment and deposition of a carbon fiber across the microscale gap between two electrodes on the membrane. The fabricated pressure sensors were tested by applying static pressure to the membrane and measuring the resistance change of the carbon fiber. The resistance change of carbon fibers clearly shows linear response to the applied pressure and the calculated sensitivities of pressure sensors are $0.25{\sim}0.35 and 61.8 ${\Omega}/k{\Omega}{\cdot}bar$ for thicker and thinner membrane, respectively. All these observations demonstrated the possibilities of carbon fiber-based pressure sensors.

An Adaptive Workflow Scheduling Scheme Based on an Estimated Data Processing Rate for Next Generation Sequencing in Cloud Computing

  • Kim, Byungsang;Youn, Chan-Hyun;Park, Yong-Sung;Lee, Yonggyu;Choi, Wan
    • Journal of Information Processing Systems
    • /
    • v.8 no.4
    • /
    • pp.555-566
    • /
    • 2012
  • The cloud environment makes it possible to analyze large data sets in a scalable computing infrastructure. In the bioinformatics field, the applications are composed of the complex workflow tasks, which require huge data storage as well as a computing-intensive parallel workload. Many approaches have been introduced in distributed solutions. However, they focus on static resource provisioning with a batch-processing scheme in a local computing farm and data storage. In the case of a large-scale workflow system, it is inevitable and valuable to outsource the entire or a part of their tasks to public clouds for reducing resource costs. The problems, however, occurred at the transfer time for huge dataset as well as there being an unbalanced completion time of different problem sizes. In this paper, we propose an adaptive resource-provisioning scheme that includes run-time data distribution and collection services for hiding the data transfer time. The proposed adaptive resource-provisioning scheme optimizes the allocation ratio of computing elements to the different datasets in order to minimize the total makespan under resource constraints. We conducted the experiments with a well-known sequence alignment algorithm and the results showed that the proposed scheme is efficient for the cloud environment.

Effect of Exercise Using an Automatic Spine Extension Device on Thoracic Kyphotic and Extension Angles

  • Kim, Ju-hyeon;Park, Seon-mi;Sin, Hyang-hee;Choi, Ho-jeong;Liu, Yaoyao;Yoo, Won-gyu
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.235-240
    • /
    • 2022
  • Background: A spinal extension and intensive rehabilitation program reduced the symptoms and pain of kyphosis, and improved function. Objects: This study aimed to demonstrate the effect of a spine extension device on the degree of thoracic kyphosis and extension angles, confirm reduction of the kyphosis angle and an increase in flexibility. Methods: Thirteen adults were enrolled in the experiment, using the spine extension device, which was set to passively extend the spine. The angle between the spinous process of the first thoracic vertebra and the spinous process of the twelfth thoracic vertebra was measured by dual inclinometer before and after using the spine extension device. Results: In the static posture, the thoracic kyphosis decreased after using the spine extension device in the thoracic extension posture, and there was a significant difference (p < 0.05); thoracic extension angle increased with statistical significance (p < 0.05). Conclusion: In this study, the thoracic kyphosis angle and thoracic extension angle of the subjects before and after using spine extension device was compared and analyzed, which proved that the spine extension device can effectively improve the mobility of spinal extension.

Investigating spurious cracking in finite element models for concrete fracture

  • Gustavo Luz Xavier da Costa;Carlos Alberto Caldeira Brant;Magno Teixeira Mota;Rodolfo Giacomim Mendes de Andrade;Eduardo de Moraes Rego Fairbairn;Pierre Rossi
    • Computers and Concrete
    • /
    • v.31 no.2
    • /
    • pp.151-161
    • /
    • 2023
  • This paper presents an investigation of variables that cause spurious cracking in numerical modeling of concrete fracture. Spurious cracks appear due to the approximate nature of numerical modeling. They overestimate the dissipated energy, leading to divergent results with mesh refinement. This paper is limited to quasi-static loading regime, homogeneous models, cracking as the only nonlinear mode of deformation and cracking only due to tensile loading. Under these conditions, some variables that can be related to spurious cracking are: mesh alignment, ductility, crack band width, structure size, mesh refinement and load increment size. Case studies illustrate the effect of each variable and convergence analyses demonstrate that, after all, load-increment size is the most important variable. Theoretically, a sufficiently small load increment is able to eliminate or at least alleviate the detrimental influence of the other variables. Such load-increment size might be prohibitively small, rendering the simulation unfeasible. Hence, this paper proposes two alternatives. First, it is proposed an algorithm that automatically find such small load increment size automatically, which not necessarily avoid large computations. Then, it is proposed a double simulation technique, in which the crack is forced to propagate through the localization zone.

Surgical Outcome of Cervical Arthroplasty Using $Bryan^{(R)}$

  • Kim, Hong-Ki;Kim, Myung-Hyun;Cho, Do-Sang;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.532-537
    • /
    • 2009
  • Objective : Recently, motion preservation has come to the forefront of emerging technologies in spine surgery. This is the important background information of the emergence of cervical arthroplasty as an alternative to arthrodesis that offers the promise of restoring normal spinal movement and reduces a kinematic strain on adjacent segments. The study was designed to evaluate early surgical outcome and radiological effects of $Bryan^{(R)}$ cervical disc prosthesis. Methods : The authors retrospectively reviewed radiographic and clinical outcomes in 52 patients who received the $Bryan^{(R)}$ Cervical Disc prosthesis, for whom follow-up data were available. Static and dynamic radiographs were measured by computer to determine the angles formed by the endplates of the natural disc preoperatively, those formed by the shells of the implanted prosthesis, the angle of functional spine unit (FSU), and the C2-7 Cobb angle. The range of motion (ROM) was also determined radiographically, whereas clinical outcomes were assessed using Odom's criteria, visual analogue pain scale (VAS) and neck disability index (NDI). Results : A total of 71 $Bryan^{(R)}$ disc were placed in 52 patients. A single-level procedure was performed in 36 patients, a two-level procedure in 13 patients, and a three-level procedure in 3. Radiographic and clinical assessments were made preoperatively. Mean follow-up duration was 29.2 months, ranging from 6 to 36 months. All of the patients were satisfied with the surgical results by Odom's criteria, and showed significant improvement by VAS and NDI score (p < 0.05). The postoperative ROM of the implanted level was preserved without significant difference from preoperative ROM of the operated level (p < 0.05). 97% of patients with a preoperative lordotic sagittal orientation of the FSU were able to maintain lordosis. The overall sagittal alignment of the cervical spine was preserved in 88.5% of cases at the final follow up. Interestingly, preoperatively kyphotic FSU resulted in lordotic FSU in 70% of patients during the late follow up, and preoperatively kyphotic overall cervical alignment resulted in lordosis in 66.6% of the patients postoperatively. Conclusion : Arthroplasty using the $Bryan^{(R)}$ disc seemed to be safe and provided encouraging clinical and radiologic outcome in our study. Although the early results are promising, this is a relatively new approach, therefore long-term follow up studies are required to prove its efficacy and its ability to prevent adjacent segment disease.

Effects of Height of the Shoe Heel in a Static Posture on Muscle Activity of the Rectus Abdominis, Erector Spinae, Rectus Femoris and Hamstring (구두 굽의 높이가 한다리 서기 자세에서 배곧은근, 척추세움근, 넙다리곧은근, 뒤넙다리근의 근활성도에 미치는 영향)

  • Lee, Won-Hwee;Lee, Hyeon-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.224-230
    • /
    • 2016
  • The purpose of this study was to examine the effects of height of the shoe heel in a one leg standing posture on the muscle activity of the rectus abdominis, erector spinae, hamstring, and rectus femoris. Twenty healthy female subjects were asked to perform a one leg standing posture with three types of shoes, which had different heights of shoe heel, 0cm, 3cm, and 7cm. Surface electromyography was used to evaluate the activities of the right rectus abdominis, erector spinae, hamstring, and rectus femoris muscles. The data was analyzed by repeated one-way ANOVA and the muscle activities among three heights of shoe heel were compared. The results showed that the muscle activities of the erector spinae and rectus femoris increased significantly according to increase height of shoe heel (p<0.05). The activity of the rectus abdominis and hamstring were not significantly different among the three height of shoe heel (p>0.05). These results suggest that the height of shoe heel affects the lumbo-pelvic alignment and center of mass; therefore, high-heeled shoes lead to musculoskeletal pain in the lumbopelvic, hip, and knee areas.

Effect of passive self-ligating bracket placement on the posterior teeth on reduction of frictional force in sliding mechanics

  • Kim, Kyu-Ry;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the static (SFF) and kinetic frictional forces (KFF) in sliding mechanics of hybrid bracket systems that involve placing a conventional bracket (CB) or active self-ligating bracket (ASLB) on the maxillary anterior teeth (MXAT) and a passive SLB (PSLB) on the maxillary posterior teeth (MXPT). Methods: The samples consisted of two thoroughbred types (group 1, anterior-CB + posterior-CB; group 2, anterior-ASLB + posterior-ASLB) and four hybrid types (group 3, anterior-CB + posterior-PSLB-type 1; group 4, anterior-CB + posterior-PSLB-type 2; group 5, anterior-ASLB + posterior-PSLB-type 1; group 6, anterior-ASLB + posterior-PSLB-type 2) (n = 13 per group). After maxillary dentition alignment and maxillary first premolars removal in the stereolithographically-made typodont system, a $0.019{\times}0.025$-inch stainless steel wire was drawn through the right quadrant of the maxillary arch at 0.5 mm/min for 5 min. The SFF and KFF were measured with a mechanical testing machine and statistical analyses were performed. Results: Four different categories of SFF and KFF were observed among all groups (all p < 0.001). Group 1 demonstrated the highest SFF and KFF; groups 4 and 3 were second and third highest, respectively. The fourth category included groups 2, 5, and 6. Placing PSLBs on the MXPT resulted in significant SFF and KFF reductions in cases with CBs on the MXAT, but not in cases with ASLBs on the MXAT. Conclusions: These data might aid in the development of a hybrid bracket system that enables low-friction sliding of an archwire through the MXPT.