• Title/Summary/Keyword: Static alignment

Search Result 76, Processing Time 0.029 seconds

Development of Seesaw-Type CSP Solder Ball Loader (CSP용 시소타입 로딩장치의 개발)

  • Lee, J.H.;Koo, H.M.;Woo, Y.H.;Lee, C.W.;Shin, Y.E.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.873-878
    • /
    • 2000
  • Semiconductor packaging technology is changed rapidly according to the trends of the micro miniaturization of multimedia and information equipment. For I/O limitation and fine pitch limitation, DIP and SOP/QFP are replaced by BGA/CSP. This is one of the surface mount technology(SMT). Solder ball is bumped n the die pad and connected onto mounting board. In ball bump formation, vacuum suction type ball alignment process is widely used, However this type has some problems such as ionization, static electricity and difficulty of fifo(first-input first-out) of solder balls. Seesaw type is reducing these problems and has a structural simplicity and economic efficiency. Ball cartridge velocity and ball aligned plate angle are Important variables to improve the ball alignment Process. In this paper, seesaw-type CSP solder ball loader is developed and the optimal velocity and plate angle are proposed.

  • PDF

Effects of Gait Training Using a Shoulder-Back Orthosis on Balance and Gait in Patients with Stroke

  • Han-Byul Youn;Jong-Kyung Lee;Yu-Min Ko;Ji-Won Park
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.200-205
    • /
    • 2023
  • Purpose: The purpose of this study is to find out how gait training with shoulder-back assistive device affects dynamic and static balance, gait of patients with stroke and to help improve body alignment, balance, and gait ability in stroke patients. Methods: Measurements were taken of the 20 subjects before intervention without shoulder-back assistive device, after intervention with device, and follow up after an hour compared. Berg balance scale used to evaluate dynamic balance; wii balance board was used to measure static balance; and gait ability were measured by timed up and go test and 10-meter walk test. To analyze the results, a one-way repeated measures analysis of variance was implemented to compare the measurements. Results: The results showed that, after wearing the shoulder-back assistive device, the subjects' dynamic balance statistically significantly improved; no statistically significant difference was observed in static balance, although their balance ability was enhanced; and their increase in gait ability was statistically significant. Conclusion: This study proved that gait training combined with a shoulder-back assistive device positively impacted dynamic and static balance, gait of patients with stroke.

Evaluation of Static Error Signal for Super Slim Optical Pick-up (초소형 광 픽업의 정적 오차 신호 검출)

  • Kang, S.M.;Cho, E.H.;Sohn, J.S.;Kim, W.C.;Park, N.C.;Park, Y.P.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.115-120
    • /
    • 2005
  • As a popularity of a portable digital device such as a cellular phone, a digital camera and a MP3 player is spreading, the demand of the mobile storage device increases rapidly. A bluray technology using 405nm laser diode and objective lens having high NA(Numerical Aperture), 0.85, satisfies a miniaturization and a high capacity which are the requirements of the portable device. To develop SFFOP(small form factor optical pickup), it is prerequisite to minimize the number of optical components and establish evaluation and assembly method of micro optical pickup system as well as mass production method of micro optical component. To minimize optical elements of optical pickup, there have been many researches to use P-HOE(Polarized Holographic Optical Element) due to its extremely small size and versatile function. However, P-HOE is handled and assembled very accurately in SFFOP. In this paper, static error signal detection method is developed for an alignment of P-HOE in SFFOP. Using developed static error signal detection method, P-HOE can be aligned very accurately with real time result of static error signals of pickup such as FES(focusing error signal) and TES(Tracking Error Signal). The developed static error signal detection method is verified by the evaluation of commercialized DVD Pickup. And finally. developed static error signal detection method is applied for the assembly of P-HOE in SFFOP system satisfies specification of BD(Blu-ray Disk).

  • PDF

Differences in Static Lower Extremity Alignment according to the History of Lateral Ankle Sprain: Efficacy and Limitation of Static Lower Limb Alignment Measurement as a Predictor of Lateral Ankle Sprain (외측 발목 염좌 병력에 따른 정적 하지 정렬 차이: 외측 발목 염좌의 예측인자로서 정적 하지 정렬 검사의 효용성과 한계점)

  • Jeon, Hyung Gyu;Ha, Sunghe;Lee, Inje;Kang, Tae Kyu;Kim, Eun Sung;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Objective: The aim of this study was to investigate 1) the difference in static lower extremity alignment (SLEA) according to a history of lateral ankle sprain (LAS), 2) to identify SLEA factors affecting LAS, and 3) to present the cut-off value and 4) the usefulness and limitations of the SLEA measurement. Method: This case-control study recruited 88 men (age: 27.78±4.69 yrs) and 39 women (age: 24.62±4.20 yrs) subjects with and without LAS. SLEA measurement protocol included Q angle, tibiofemoral angle, genu recurvatum, rear foot (RF) angle, tibal varum and torsion, navicular drop, ankle dorsiflexion range of motion (DF ROM). Independent t-test, logistic regression and receiver operating characteristic (ROC) curve were used for statistical analysis. Results: Men with a history of LAS had significantly smaller Q angles both in standing and in supine position, while women with a history of LAS had significantly greater DF ROM in non-weight bearing (NWB; p < 0.05). Logistic regression model suggests tibial varum (OR = 0.779, p = 0.021) and WB DF ROM (OR = 1.067, p = 0.045) were associated with LAS in men. In case of women, there were no significant SLEA factors for LAS, however, ROC curve analysis revealed standing RF angle (AUC = 0.647, p = 0.028) and NWB DF ROM (AUC = 0.648, p = 0.026) could be affecting factors for LAS. Conclusion: There are differences in SLEA according to the history of LAS, furthermore, the identified items were different by sex. In case of men, tibial varum and WB DF ROM affect LAS occurrence. Standing RF angle and NWB DF ROM of women could be a predictor for LAS. However, since the sensitivity and specificity in most of the SLEA measurements are low, kinematic in dynamic tasks should be considered together for a more accurate evaluation of LAS risk.

Study on Offshore Stabbing Guide design (해양 스태빙 가이드 설계 고찰)

  • 조철희;홍성근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.69-77
    • /
    • 1999
  • The stabbing guide is often used to guide an add-on pile into an existing pile in offshore jacket installation. It provides a pile alignment for a welding tie-in in static condition as well. Even stabbing guide is an essential component in pile installation, it is not considered as a permanent offshore structure. In this regard, there is not a define design guideline proposed. In API RP 2A WSD, it briefly define the design considerations of stabbing guide. The failure of stabbing guide can cause a greate economical loss and a serious impact to the project schedule. Stabbing guide design should consider many factors considering actual work conditions for both static and dynamic situations. In the paper, a design method is proposed by appling the plate theory and it is confirmed numerically with FEM modeling. The geometry of stabbing guide is assumed as a cylinder shape with various wall thickness and effective length. The various thickness, effective length and pile size are compared for stable stabbing guide design.

  • PDF

A 120 GHz Voltage Controlled Oscillator Integrated with 1/128 Frequency Divider Chain in 65 nm CMOS Technology

  • Kim, Namhyung;Yun, Jongwon;Rieh, Jae-Sung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.131-137
    • /
    • 2014
  • A 120 GHz voltage controlled oscillator (VCO) with a divider chain including an injection locked frequency divider (ILFD) and six static frequency dividers is demonstrated using 65-nm CMOS technology. The VCO is designed based on the LC cross-coupled push-push structure and operates around 120 GHz. The 60 GHz ILFD at the first stage of the frequency divider chain is based on a similar topology as the core of the VCO to ensure the frequency alignment between the two circuit blocks. The static divider chain is composed of D-flip flops, providing a 64 division ratio. The entire circuit consumes a DC power of 68.5 mW with the chip size of $1385{\times}835{\mu}m^2$.

Electro-optical property of twisted nematic liquid crystal cells with ion-beam irradiated polymer surface (이온빔처리된 고분자막을 이용한 TN 셀의 전기광학특성)

  • Kim, Dae-Hyun;Ok, Chul-Ho;Park, Hong-Gyu;Kim, Byoung-Yong;Hwang, Jeong-Yeon;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.338-338
    • /
    • 2009
  • To date, rubbing has been widely used to align LC molecules uniformly. Although rubbing can be simple, it has fundamental problems such as the generation of defects by dust and static electricity, and difficulty in achieving a uniform LC alignment on a large substrate. Therefore, noncontact alignment has been investigated. Ion beam induced alignment method, which provides controllability, nonstop process, and high resolution display. We investigated the high pretilt angle effects on electro-optical properties of ion beam (IB)-irradiated liquid crystal cells. on a blended polymer surface. High pretilt angle of liquid crystals IB-irradiated on a blended polymer surface including such as 5% and 10% of homeotropic polymer contents can' be achieved. The threshold voltages of IB-irradiated twisted nematic (TN) cells on a blended polymer surface decrease with increasing the pretilt angle. Also, the rising time of IB-irradiated TN cells decreases with increasing the pretilt angle. However the decay time of IB-irradiated TN cells increases with increasing the pretilt angle. Consequently, the electro-optical properties of IB-irradiated TN cells depend strongly on the pretilt angle in a blended polymer surface.

  • PDF

The Effects of Static Hamstring Stretching on Hip Motion and Lumbo-Pelvic Kinematics

  • Oh, Jaeseop;Kang, Minhyeok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.3
    • /
    • pp.2102-2106
    • /
    • 2020
  • Background: Static hamstring stretching exercises have been widely used to improve flexibility of the hamstring muscles. However, few studies have examined the influence of standing static hamstring stretching (e.g., jack-knife stretching) on movements of the lumbopelvic-hip complex. Objectives: To examine the short-term effects of jack-knife stretching on movements of the lumbopelvic-hip complex. Design: Case series. Methods: Fourteen participants with hamstring tightness (8 male, 6 female) were recruited. Participants performed jack-knife stretching for 150 s. Before and after stretching, participants performed the finger-to-floor distance (FFD), sit and reach (SRT), active knee extension (AKE), passive straight leg raising (PSLA), and active straight leg raising (ASLR) tests as well as pelvic tilt while standing to identify the effects of stretching. Results: There were significant improvements in the FFD, SRT, AKE, PSLA, and ASLR tests after stretching. However, pelvic tilt angle while standing did not significantly change. Conclusion: Jack-knife stretching can be a useful exercise to improve flexibility of the hamstring muscles, but not pelvic alignment while standing.

The Effect of Thoracic Joint Mobilization on the Changes of the Thoracic Kyphosis Angle and Static and Dynamic Balance

  • Jeong, Hae-Jin;Kim, Byeong-Jo
    • Biomedical Science Letters
    • /
    • v.25 no.2
    • /
    • pp.149-158
    • /
    • 2019
  • The objective of this study was to evaluate the effects of thoracic mobilization (TM) on the angle of thoracic kyphosis, and static and dynamic balances by application period. The subjects of this study were 18 adult males and females (${\geq}20years\; old$) who had the angle of thoracic kyphosis equal to or higher than $40^{\circ}$. A pre-test was conducted for all subjects and TM was carried out. Data were collected before the intervention, 3 weeks after the intervention, and 6 weeks after the intervention. It was measured three times per measurement and mean values were used for the analysis. The results of this study showed that the angle of thoracic kyphosis significantly (P<.05) decreased after applying TM. However, the migration area ($mm^2$) of the center of pressure (COP) in the static balance did not vary significantly. In the case of the dynamic balance, when eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks. When eyes were open, the migration area ($mm^2$) of the COP significantly (P<.05) decreased after 3 weeks and 6 weeks. Therefore, an intervention for improving the human body alignment and balance should be applied for a long-term, rather than a short-term, in order to be effective.

Change of Balance Ability in Subjects with Pain-Related Temporomandibular Disorders

  • Ja Young Kim;Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.321-325
    • /
    • 2022
  • Purpose: Temporomandibular disorder (TMD) is a condition defined as pain and dysfunction of temporomandibular joints and masticatory muscles. Abnormal interconnections between temporomandibular muscles and cervical spine structures can cause the changes of postural alignment and balance ability. The aim of this study was to investigate changes in static balance ability in subjects with painrelated TMD. Methods: This study conducted on 25 subjects with TMD and 25 control subjects with no TMD. Pressure pain thresholds (PPTs) of the masseter and temporalis muscles were measured using a pressure algometer. Static balance ability was assessed during one leg standing using an Inertial Measurement Unit (IMU) sensor. During balance task, the IMU sensors measured motion and transfer movement data for center of mass (COM) motion, ankle sway and hip sway. Results: PPTs of masseter and temporalis muscles were significantly lower in the TMD group than in the control group (p<0.05). One leg standing, hip sway, and COM sway results were significantly greater in the TMD group (p<0.05), but ankle sways were not different between group. Conclusion: We suggest pain-related TMD is positively related to reduced PPTs of masticatory muscles and to static balance ability. These results should be considered together with global body posture when evaluating or treating pain-related TMD.