• Title/Summary/Keyword: Static Synchronous Series Compensator

Search Result 41, Processing Time 0.023 seconds

Installation of 80MVA UPFC(Unified Power Flow Controller) for improving voltage stability and reducing heavy load in KEPCO power systems (한전계통의 전압안정도 향상 및 과부하 해소를 위한 80MVA UPFC(Unified Power Flow Controller) 설치)

  • Oh, Kwan-Il;Chang, Byung-Hoon;Jeon, Young-Soo;Park, Sang-Tae;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.262-265
    • /
    • 2001
  • 최근 전력계통의 과부하, 전압안정도 등의 문제에 대한 해결책으로 FACTS (Flexible AC Transmission Systems)가 대두되고 있다. FACTS 설비에는 TCSC (Thyristor-Controlled Series Capacitor), SSSC (Static Synchronous Series Capacitor)와 같은 직렬 기기와 SVC(Static Var Compensator), STATCOM(STATic COMpensator) 와 같은 병렬기기 그리고, 본 논문에서 다루는 UPFC와 같은 직 병렬기기로 나누어진다. UPFC는 SSSC와 STATCOM을 결합한 형태로 유 무효전력을 동시에 보상할 수 있는 FACTS 기기이다. 본 논문에서는 한전 계통의 전압안정도 향상과 과부하 해소를 위해 강진S/S에 설치예정인 80MVA UPFC의 하드웨어 특성과 주변계통의 특성을 소개하고, UPFC와 한전 계통의 연계방안과 시험방안을 설명한다.

  • PDF

Steady-state Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Xu, X.K.;Lam, B.P.
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.161-167
    • /
    • 2003
  • This paper presents a study performed to investigate the steady-state operational strategies of UPFCs in the Jeollanam-Do system in Korea. The objective of the study was to determine the UPFC operating points under normal and contingency conditions. The study consists of developing load flow models to simulate different load levels with and without UPFCs in the system, assessing the effectiveness of UPFCs by contingency analysis, and introducing optimal corrective actions for removing voltage problems caused by contingencies. The paper describes analytical tools, models and approach. It also includes analysis and discussion of the study results. The paper contributes to the area of transmission operational studies with FACTS applications.

Dynamic Characteristic Analysis of SSSC based on Multi-bridge PWM Inverter

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.718-722
    • /
    • 2001
  • This paper proposes an SSSC based on multi-bridge inverters in PWM scheme. The proposed system consists of 6 H-bridge inverter modules per phase. The dynamic characteristic of proposed system was analyzed by simulation with EMTP codes, assuming that the SSSC is inserted in the 154-kV transmission line of one-machine-infinite-bus power system. The feasibility of hardware implementation was verified through experimental works with a scaled-model. The proposed system can be directly inserted in the transmission line without coupling transformers, and has flexibility in expanding the operation voltage by increasing the number of H-bridges.

  • PDF

Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC (다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석)

  • 한병문;박덕희;김성남
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

Performance Analysis of UPFC by Simulation & Scaled Hardware Model (시뮬레이션과 축소모형에 의한 UPFC의 성능해석)

  • Park, Ji-Yong;Baek, Seung-Taek;Kim, Hui-Jong;Han, Byeong-Mun;Han, Hak-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.10
    • /
    • pp.579-586
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active power flow through the ac transmission line. The design of control system for UPFC was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. Both models would be very effective for analyzing the dynamic performance of the Unified Power Flow Controller.

  • PDF

Enhancement of Interface Flow Limit using Static Synchronous Series Compensators

  • Kim Seul-Ki;Song Hwa-Chang;Lee Byoung-Jun;Kwon Sae-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.313-319
    • /
    • 2006
  • This paper addresses improving the voltage stability limit of interface flow between two different regions in an electric power system using the Static Synchronous Series Compensator (SSSC). The paper presents a power flow analysis model of a SSSC, which is obtained from the injection model of a series voltage source inverter by adding the condition that the SSSC injection voltage is in quadrature with the current of the SSSC-installed transmission line. This model is implemented into the modified continuation power flow (MCPF) to investigate the effect of SSSCs on the interface flow. A methodology for determining the interface flow margin is simply briefed. As a case study, a 771-bus actual system is used to verify that SSSCs enhance the voltage stability limit of interface flow.

UPFC Modelling on RTDS (RTDS(Real Time Digital Simulator)를 이용한 UPFC(Unified Power Flow Controller) 모델링)

  • 김광수;이상중
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.47-50
    • /
    • 2001
  • In order for effective operation of existing power systems, introduction of the so-called FACTS(Flexible AC Transmission System) such as SVC and UPFC etc, is unavoidable. The UPFC(Unified Power Flow Controller) is composed of STATCOM(Static Compensator) and SSSC(Static Synchronous Series Compensator), and is used to control the magnitude and phase angle of injected sources which are connected bothin series and in parallel with the transmission line to control the power flow and bus voltages. This paper presents a UPFC simulation on RTDS. The voltage and phase angle of a system have been analyzed by regulating the firing angle inside the UPFC.

  • PDF

Transient Stability Enhancement by DSSC with Fuzzy Supplementary Controller

  • Khalilian, Mansour;Mokhtari, Maghsoud;Nazarpour, Daryoosh;Tousi, Behrouz
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.415-422
    • /
    • 2010
  • The distributed flexible alternative current transmission system (D-FACTS) is a recently developed FACTS technology. Distributed Static Series Compensator (DSSC) is one example of DFACTS devices. DSSC functions in the same way as a Static Synchronous Series Compensator (SSSC), but is smaller in size, lower in price, and possesses more capabilities. Likewise, DSSC lies in transmission lines in a distributed manner. In this work, we designed a fuzzy logic controller to use the DSSC for enhancing transient stability in a two-machine, two-area power system. The parameters of the fuzzy logic controller are varied widely by a suitable choice of membership function and parameters in the rule base. Simulation results demonstrate the effectiveness of the fuzzy controller for transient stability enhancement by DSSC.

Development of UPFC GTO Thyristor Valve Test Equipment (UPFC GTO Thyristor VTE(Valve Test Equipment) 개발)

  • Kim, Soo-Yeol;Chang, Byung-Hoon;Yoon, Jong-Soo;Kim, Yong-Hak;Baek, Doo-Hyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.391-395
    • /
    • 2008
  • KEPCO 80MVA UPFC has been operated in Gangjin Substation since May 2003. This UPFC is composed of 40MVA shunt inverter and 40MVA series inverter, and developed in technical cooperation between Hyosung and Siemens. KEPCO has tried to localize UPFC control technique after its installation and developed GTO Thyristor Valve Test Equipment for annual maintenance test. The development of this equipment make it possible to process GTO Thyristor module test automatically and manage historic data systematically, which could improve UPFC reliability.

Optimal Particle Swarm Based Placement and Sizing of Static Synchronous Series Compensator to Maximize Social Welfare

  • Hajforoosh, Somayeh;Nabavi, Seyed M.H.;Masoum, Mohammad A.S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.501-512
    • /
    • 2012
  • Social welfare maximization in a double-sided auction market is performed by implementing an aggregation-based particle swarm optimization (CAPSO) algorithm for optimal placement and sizing of one Static Synchronous Series Compensator (SSSC) device. Dallied simulation results (without/with line flow constraints and without/with SSSC) are generated to demonstrate the impact of SSSC on the congestion levels of the modified IEEE 14-bus test system. The proposed CAPSO algorithm employs conventional quadratic smooth and augmented quadratic nonsmooth generator cost curves with sine components to improve the accurate of the model by incorporating the valve loading effects. CAPSO also employs quadratic smooth consumer benefit functions. The proposed approach relies on particle swarm optimization to capture the near-optimal GenCos and DisCos, as well as the location and rating of SSSC while the Newton based load flow solution minimizes the mismatch equations. Simulation results of the proposed CAPSO algorithm are compared to solutions obtained by sequential quadratic programming (SQP) and a recently implemented Fuzzy based genetic algorithm (Fuzzy-GA). The main contributions are inclusion of customer benefit in the congestion management objective function, consideration of nonsmooth generator characteristics and the utilization of a coordinated aggregation-based PSO for locating/sizing of SSSC.